• Title/Summary/Keyword: heating space

Search Result 675, Processing Time 0.026 seconds

Case Study on the Energy Consumption Unit of District Apartments (지역난방 공동주택의 에너지원별 원단위 사례분석)

  • Lee, Wang-Je;Kang, Eun-Chul;Lee, Euy-Joon;Oh, Byung-Chil;Shin, U-Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.10
    • /
    • pp.474-480
    • /
    • 2014
  • This study investigated the total energy consumption and the energy consumption by type of 31 apartment complexes in Daejeon. The energy is supplied to the apartments from district heating, and can be divided into hot water, electricity, and gas. Hot water is used in for space heating and for domestic hot water (DHW), and electricity is used for plugs, cooling, ventilation, and public utilities (street lights, pumps, elevators, etc.). All gas supplied from district heating is used for cooking. As a result, the consumption unit of each energy source of independent dwelling areas was calculated to be $103.7kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$) for thermal energy, $48.0kWh/m^2{\cdot}a$ ($4,646kWh/H{\cdot}a$) for electricity, and $10.5kWh/m^2a$ ($1,015kWh/H{\cdot}a$) for gas, so the entire consumption was calculated to be $162.3kWh/m^2{\cdot}a$ ($15,692kWh/H{\cdot}a$).

A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society (18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.27 no.3
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

The Development of Thermal Model for Safety Analysis on Electronics in High-Speed Vehicle (고속 비행체 전자 장비의 안전성 예측을 위한 열해석 모델 구축)

  • Lee, Jin Gwan;Lee, Min Jung;Hwang, Su Kweon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.5
    • /
    • pp.437-446
    • /
    • 2021
  • As flying vehicle's speed is getting faster, the magnitude of aerodynamic heating is getting bigger. High-speed vehicle's exterior skin is heated to hundreds of degrees, and electrical equipments inside the vehicle are heated, simultaneously. Since allowable temperature of electrical equipments is low, they are vulnerable to effect of aerodynamic heating. These days, lots of techniques are applied to estimate temperature of electrical equipments in flight condition, and to make them thermally safe from heating during flight. In this paper, new model building technique for thermal safety analysis is introduced. To understand internal thermal transient characteristic of electrical equipment, simple heating experiment was held. From the result of experiment, we used our new building technique to build thermal analysis model which reflects thermal transient characteristic of original equipment. This model can provide internal temperature differences of electrical equipment and temperature change of specific unit which is thermally most vulnerable part in the equipment. So, engineers are provided much more detailed thermal analysis data for thermal safety of electrical equipment through this technique.

A Study on the Plan-type of Pit-dwelling site in Joseon dynasty - Focusing on the Pit-dwelling of Seoul·Gyeonggi region - (조선시대 수혈주거지의 평면유형 연구 -서울·경기지역 수혈주거지를 중심으로-)

  • Seo, Ji-Eun;Hong, Seung-Jae
    • Journal of architectural history
    • /
    • v.24 no.3
    • /
    • pp.43-56
    • /
    • 2015
  • Researches on the pit dwellings in the Joseon Dynasty era have been constantly conducted in the archeology field since the beginning of the 2000s. Most of the related researches in the past have been on the classification and chronological record of dwelling types in archeology, but architectural researches on the dwelling history that is connected from the prehistoric age to the Joseon Dynasty era are insufficient. There are no big differences between the excavated pit dwellings of the Joseon Dynasty era and those of the prehistoric age, so pit dwellings were considered to have been used as dwellings for common people until the Joseon dynasty era. This fact is confirmed by the frequency and density of pit dwellings. In this research, what space composition of the pit dwellings that are equipped with the Korean floor heating system is shown according to the plan types was examined and the development and transition process from pit dwellings to Folk houses were analyzed and their correlations with the Folk houses of the Joseon Dynasty era were examined. The Folk house form did not start with the form of the house on the ground but originate from the introduction of Ondol, the Korean floor heating system, to pit dwellings. As the Korean floor heating system is used, the room and kitchen space are composed in the pit dwelling, and the kitchen is expanded to the one that separates the fireplace for cooking to avoid heating that is unnecessary for the summer season. As the size of the dwelling was getting bigger, the division of the space is made by the pillars that support the interior space. Also, the dwelling is expanded into a single row house and a double row house according to the progress direction of Ondol. In other words, the pit dwellings in the Joseon Dynasty era develops with making up diverse floors through the combination and expansion of Ondol and kitchen according to the dweller's convenience and life style and surrounding environment. This research is significant in the sense that it helps understand the formation and development process of our traditional Folk houses and fills the gap between the pit dwellings, which have been dealt with inadequately, and traditional Folk houses in the Korean dwelling history.

Analysis on the Effect of the Crown Heating System and Warm Nutrient Supply on Energy Usage in Greenhouse, Strawberry Growth and Production (관부 난방시스템과 온수 양액 공급이 온실 에너지 사용량, 딸기 생육 및 생산성에 미치는 영향 분석)

  • Lee, Taeseok;Kim, Jingu;Park, Seokho;Lee, Jaehan;Moon, Jongpil
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.271-277
    • /
    • 2021
  • In this study, experiments of local heating on crown and supplying warm nutrient for energy saving and improving growth of 'Seolhyang' strawberry were conducted. The temperature of inside and crown in greenhouses which were control (space heating 8℃) and test (space heating 5℃+crown heating) was measured. In the control greenhouse, the average of temperature and humidity in December was 7.1℃, 87.2%, respectively. In the test greenhouse, the average of temperature and humidity in December was 5.7℃, 88.7%. The temperature of crown and inside the bed were 7.9℃, 10.8℃ in control, 9.3℃, 12.7℃ in test. During the test period, the total 16,847×103 kcal of energy was consumed in control greenhouse including space heating. In test greenhouse including space heating, crown heating and warm water supplying, total 9,475.7×103 kcal of energy was consumed. So, energy consumption in test was 43.8% less than in the control. The total yields of strawberry during test period were 412.7g/plant for test greenhouse and 393.3g/plant for control greenhouse respectively.

An Experimental Study on the Ground Source Heat Pump System for Heating Economic Efficiency and Reduction Amount of $CO_2$ (지열 시스템의 난방 경제성 및 $CO_2$ 절감 실증 연구)

  • Nam, Leem-Woo;Paek, Gi-Dong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.25-30
    • /
    • 2007
  • The final energy consumption in the building sector in Korea represents almost 20% of the total energy consumption. Besides, Space heating and hot water generation in Korea are based on fossil fuels, with a serious environmental impact. This study describes thermal performance of heating demonstration system using close-loop ground source heat pump installed at Korean minjok leadership academy. The results of the experimental study, it retrieve the investment cost for 3years 8months and reduction amount of $CO_2$are 293,900 $kgCO_2$.

  • PDF

Simnlation of a Thermal Behavior in Solar Heating and Cooling System with respect to Demand Room Temperature (실내 설정온도에 따른 태양열 냉난방 시스템의 동적 거동 해석)

  • Jang, H.Y.;Lee, S.B.;Chung, K.T.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3446-3451
    • /
    • 2007
  • The thermal behavior of a building in response to heat input from an active solar space heating system is analysed to determine the effect of the variable storage tank temperature on the cycling rate, on and off temperature of a heating cycle and on the comfort characteristics of room air temperature. A computer simulation of the system behavior has been performed and verified by comparisons with various parameters. Especially, this study is focused on the effect of the system's performance when subjected to dynamic cooling loads. The heat input to the absorption system is provided by an array of solar collectors that coupled to a thermal storage tank.

  • PDF

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer (모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구)

  • Moon, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

Energy Performance and Improvement in University Library - Concentrated on 'K'University Library located in Seojong City -

  • Roh, Ji Woong
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.47-52
    • /
    • 2014
  • The problem of energy consumption is more serious in university buildings than primary, middle and high school buildings. Because university buildings have generally heating and cooling systems, and various incidental facilities. In university, the library is one of the building that many people use and the most energy is spent. So, investigation on energy saving is very important and urgent. This study aims finally to present the guideline for low-energy design of University library by aiding a designer to select best solution in the side of energy-saving. In this paper, composition of space, utilization schedule and performance of construction materials are grasped, some primary factors that effect to energy saving are analyzed by energy simulation. The result of this study is as follows; First, the subject library has more cooling load than heating load because of cooling load generated during middle season. Second, green roofs is the most effective to heating load saving, but not to cooling energy. Third, outdoor air cooling is the most effective to cooling energy saving among the investigated strategies included in this study.