• Title/Summary/Keyword: heating space

Search Result 675, Processing Time 0.028 seconds

Electron Beam Propagation in a Plasma

  • Min, Kyoung-W.;Koh, Woo-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 1988
  • Electron beam propagation in a fully ionized plasma has been studied using a one-dimensional particle simulation model. We compare the results of electrostatic simulations to those of electromagnetic simulations. The electrostatic results show the essential features of beam-plasma interactions. It is found that the return currents are enhanced by the beam-plasma instability which accelerates ambinet plasmas. The results also show the heating of ambient plasmas and the trapping of plasmas due to the locally generated electric field. The electromagnetic simulations show much the same results as the electrostatic simulations do. The level of the radiation generated by the same non-relativistic beam is slightly higher than the noise level. We discuss the results in context in context of the heating of coronal plasma during solar flares.

  • PDF

A Study on Indoor and Personal Exposures Concentrations to Carbon Monoxide in the Asan Area

  • Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.1-3
    • /
    • 2000
  • Indoor carbon monoxide (CO) concentration and personal CO exposures were measured Asan where CO poisoning from twenty coal usage briquette as a domestic fuel to cook and space heating. Twenty-five were houses selected from the Asan area for the survey conducted in February 1997. Newly developed passive CO samplers were placed in the kitchen and living room for the indoor concentration measurement and were worn by homemakers for personal exposure monitoring. The daily average of indoor CO concentration was 16ppm in the kitchen and 10ppm in the living room. The indoor concentration and personal exposures to CO were different in types of the space heating system. House ventilating methods and socioeconomic conditions were also important factors in determining the indoor and personal CO level in Asan.

  • PDF

Launch Stage Thermal Analysis on a Mass Varying Satellite Box by Analytical Solutions (해석해를 이용한 질량변화가 있는 위성 부품에 대한 발사시 열해석)

  • Choi, Joon-Min;Kim, Hui-Kyung;Hyun, Bum-Seok
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.163-168
    • /
    • 2003
  • Analytical approach is applied to predict temperature of satellite box under worst hot condition from fairing jettison to separation. The box is tried to solve analytically which is exposed to known environmental heating condition and has internal heating and irradiation to space. For a single thermal mass, governing equation for temperature is simplified to 1st order ordinary differential equation(ODE) by several assumptions. Two cases are considered. The one is for constant mass box and the other is for mass-varying box. Each case has three different analytical solution by sign of constant term in ODE. One analytical solution for constant mass is applied to physical launch stage condition. It is concluded that the present analytical method can be used to quick predict the temperature of a satellite box and check whether a satellite is safe against space environment during launch stage.

  • PDF

Data Analysis of KOMPSAT Thermal Test in Simulated On-orbit Environment

  • Kim, Jeong-Soo;Chang, Young-Keun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.30-42
    • /
    • 2000
  • On-orbit thermal environment test of KOMPSAT was performed in early 1999. An analysis of the test data are addressed in this paper. For the thermal-environmental simulation of spacecraft bus, an artificial heating through the radiator zones and onto some critical heat-dissipating electronic boxes was made by Absorbed-heat Flux Method. Test data obtained in terms of temperature history were reduced into flight heater duty cycles and converted into the total electrical power required for spacecraft thermal control. Verification result of flight heaters dedicated to the bus thermal control is presented. Additionally, an exhaustive heating-control process for maintaining the spacecraft thermally safe and for realistic simulation of the orbital-thermal environment during the test are graphically shown. Qualitative suggestions to post-test model correlation are given in consequency of the analysis.

  • PDF

A Study of Ion-Hybrid Instability in the Mixed Plasma (혼합 플라즈마 내의 이온-이온 교잡파의 불안정성 연구)

  • 김수용
    • Journal of Astronomy and Space Sciences
    • /
    • v.4 no.2
    • /
    • pp.81-88
    • /
    • 1987
  • There are more oxygen ions than hydrogen ions in the auroral field zone. We consider both analytic and numerical simulation study of the heating of hydrogen and oxygen ions by auroral electrons. With the low drift speed of electron beams, the ion-ion hybrid wave becomes unstable instead of the lower hydrid wave so that a preferential heating of oxygen ions occurs.

  • PDF

Ammonia decomposition over titanium carbides

  • Choi, Jeong-Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.6
    • /
    • pp.269-273
    • /
    • 2012
  • Ammonia decomposition over titanium carbides were investigated using eight different samples which have been synthesized by TPR (temperature-programmed reduction) method of titanium oxide ($TiO_2$) with pure $CH_4$. The resulting materials which were synthesized using wo different heating rates and space velocity exhibited the different surface areas. These results indicated that the structural properties of these materials have been related to heating rates and space velocity employed. The titanium carbides prepared in this study proved to be active for ammonia decomposition, and the activity changed with the particle size/surface area. These showed the relationship between ammonia decomposition activity and the different active species. Compared to molybdenum carbide, the titanium carbides were one order of magnitude less active, suggesting the correlation between the activity difference and the degree of electron transfer between metals and carbon in metal carbides.

The Analysis of Optimum Design Parameters for a Solar Space Heating System through Computer Simulation (시뮬레이션에 의한 태양열 난방의 최적설계에 관한 연구)

  • Seoh, Jeong-Il;Lee, Young-Soo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.175-186
    • /
    • 1985
  • This paper presents a method for estimating the useful output of solar space heating system and estimates their performance with variance of collector size, storage volume, collector tilt and other factors . The analysis is performed by the computer simulation and by 'running' conceptual systems against solar intensities and ambient temperature for a model year stored in a computer. System performance is analyzed on monthly and yearly basis respectively and at the same time, the economics of various systems are evaluated . And also, this paper shows how an optimized design can be selected for any locality for which solar data, economic parameters and system performance are provided. It is shown that storage volume of 75 liter per $m^2$ of solar collector lead to the best design.

  • PDF

The temperature distributions of the curing space according to blocking the opening of gang-form at the apartment in the cold weather (동절기 공동주택 갱폼 개구부 천막보양에 따른 보양 온도 분포 분석)

  • Cho, Hong-Bum;Song, Jin-Hee;Kim, Young-Sun;Choi, Ji-Su;Lee, Kyu-Nam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.140-141
    • /
    • 2022
  • CFD analysis was performed to analyze the temperature distribution of the inner space of the curing house according to blocking the opening of the gang-form with a tent in case of concrete pouring and heat curing of the apartment house during the winter season. If the gang-form opening is closed with a tent during internal heating using a hot air blower in the winter, the internal temperature rises compared to the non-reserved due to air-tightness of the curing spaces, and uniform temperature distribution can be ensured. In addition, it is possible to increase curing efficiency by reducing the amount of heat supplied and shortening the heating time.

  • PDF

Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger (수평형 지열 히트펌프 시스템의 냉난방 성능 분석)

  • Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.230-239
    • /
    • 2012
  • Ground-coupled heat pump (GCHP) systems utilize the immense renewable storage capacity of the ground as a heat source or sink to provide space heating, cooling, and domestic hot water. The main objective of the present study is to investigate the cooling and heating performance of a small scale GCHP system with horizontal ground heat exchanger (HGHE). In order to evaluate the performance, a water-to-air ground-source heat pump unit connected to a test room with a net floor area of 18.4 m2 and a volume of 64.4 m3 in the Korea Institute of Construction Technology ($37^{\circ}39'N$, $126^{\circ}48'E$) was designed and constructed. This GCHP system mainly consisted of slinky-type HGHE with a total length of 400 m, indoor heat pump, and measuring devices. The peak cooling and heating loads of the test room were 5.07 kW and 4.12 kW, respectively. The experimental results were obtained from March 15, 2011 to August 31, 2011 and the performance coefficients of the system were determined from the measured data. The overall seasonal performance factor (SPF) for cooling was 3.31 while the system delivered heating at a daily average performance coefficients of 2.82.

TRNSYS Dynamic Simulation for Solar Heating and Cooling Load Estimations (태양열 냉난방 부하산정을 위한 TRNSYS 동적 시뮬레이션)

  • Choi, Chang-Yong;Ko, Sang-Cheol;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • This paper presents the heating and cooling load estimations for the library of a cultural center building located in Gwangju Korea by TRNSYS with Type 56 of multi-zone building components. In this study, energy rate control mode is selected and the design temperatures for heating and cooling are specified respectively as 20oC and 26oC. Reading rooms of the library are located on the third floor of the cultural center building, and this third floor space is modeled as the five thermal zones for the TRNSYS simulation. Among the five zones, attention is given to the two zones which are the reading rooms 1 and 2. Since these two zones are to be heated and cooled by the solar thermal system which is planned to be installed in the building, dynamic thermal behaviors of the two zones are analyzed by the heating and cooling load estimations.