• 제목/요약/키워드: heating information

검색결과 516건 처리시간 0.022초

열절연 구조를 이용한 가변광감쇠기의 특성에 관한 연구 (A Study on the Characteristics of Variable Optical Attenuators Using Heat Insulating Structures)

  • 양동평;김정근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(1)
    • /
    • pp.321-324
    • /
    • 2004
  • In this paper, attenuation characteristics of silica-based variable optical attenuator (VOA) with heat insulating structures are investigated by variations of structural parameters and heating power at wavelength 1.55${\mu}m$. The characteristics of power dissipation and attenuation at this VOA was optimized in terms of heating insulating width, under-cladding height and over-cladding height. The optimized maximum attenuation of this VOA was achieved about 31dB at heating power 150mW.

  • PDF

열피로 수명을 고려한 지역난방 배관의 최적화 (Optimization of District Heating Pipes Considering Thermal Fatigue Life)

  • 안민용;장윤석;최재붕;김상호;김연홍;김영진
    • 한국정밀공학회지
    • /
    • 제23권6호
    • /
    • pp.143-150
    • /
    • 2006
  • Recently, in proportion to increased demand on environmentally-friendly heat source, efficient management of district heating(DH) system becomes one of important issue. The objectives of this paper are to systematize data processing of transition temperature, investigate the effect of temperature variations on thermal fatigue and find out a way to improve design fractures of Korean DH pipes. For this purpose, reliable fatigue lift evaluation procedures are examined and applied to quantify thermal fatigue lives. Also, as a prototypal optimization analysis results, mean value of original cross sectional area of selected pipes was reduced 18.6% sustaining their sufficient margins against fatigue failure. So, it is anticipated that the output of this research can be used as useful information of optimal design and operation in the future.

비선형계획법을 이용한 건물의 외피최적화 방법 (A Study on the Optimization Method of Building Envelope using Non-linear Programming)

  • 원종서;이경회
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.17-24
    • /
    • 2003
  • The purpose of this study is to present rational methods of multi-criteria optimization of the envelope of buildings. The object is to determine the optimum R-value of the envelope of a building, based on the following criteria: minimum building costs (including the cost of materials and construction) and yearly heating costs. Mathematical model described heat losses and gains in a building during the heating season. It takes into consideration heat losses through wall, roof, floor and windows. Particular attention was paid to have a more detailed description of heat gains due to solar radiation. On the assumption that shape of building is rectangle in order to solve the problem, optimum R-value of the envelope of a building is determined by using non-linear programing methods(Kuhn-Tucker Conditions). The results constitute information for designers on the optimum R-value of a building envelope for energy saving buildings.

쿤-터커 조건을 이용한 건물의 에너지성능과 비용 최적화방법 (Optimization Method of Building Energy Performance and Construction Cost Using Kuhn-Tucker Conditions)

  • 원종서;구재오
    • KIEAE Journal
    • /
    • 제3권2호
    • /
    • pp.51-58
    • /
    • 2003
  • The purpose of this study is to present rational methods of multi-criteria optimization of the shape of energy saving buildings. The object is to determine the optimum dimension of the shape of a building, based on the following criteria: minimum building costs (including the cost of materials and construction) and yearly heating costs. Mathematical model described heat losses and gains in a building during the heating season. It takes into consideration heat losses through wall, roof, floor and windows. Particular attention was paid to have a more detailed description of heat gains due to solar radiation. On the assumption that shape of building is rectangle in order to solve the problem, the proportions of wall length and building height are determined by using non-linear programing methods(Kuhn-Tucker Conditions). The results constitute information for designers on the optimum proportions of wall lengths, height, and the ratios of window to wall areas for energy saving buildings.

주파수 추종과 정전력 제어가 가능한 고주파 유도가열기의 병렬 공진형 인버터에 대한 연구 (Study on the Parallel Resonant Inverter of an High Frequency Induction Heating System which the Frequency Tracking and the Power Regulation is possible)

  • 김남수;김태언;김승철;임영도
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.63-66
    • /
    • 2002
  • This paper has been studied the parallel resonant inverter which controlling the constant power and tracking the load resonant frequency with PLL is possible, in order to minimize switching losses. The current-fed full-bridge type parallel resonant inverter of an induction heating system was composed of IGBT in switching device. For regulating the output power of an induction heating system, the Fuzzy controller is used. The Fuzzy controller makes the control signal for a stable power regulating control and when reference is changed, it is superior to adaptability. It has been evaluated a stable behavior for a noise with switching and a load disturbance.

  • PDF

기대지열온도하에서 GDHS의 경제성분석 사례연구 (A Case Study for the Economic Feasibility Model and Analysis of a GDHS Given Geothermal Temperature)

  • 양문희;김태유;이상규
    • 대한산업공학회지
    • /
    • 제23권1호
    • /
    • pp.115-127
    • /
    • 1997
  • A GDHS(Geothermal District Heating System) is a heating system supplying a group of districts with heat extracted from geothermal sources. The advantages of GDHS include saving fuel consumption as well as reducing air pollution. This paper presents a case study for the economic feasibility model and analysis of a GDHS with which central/individual heating systems are replaced. Configuring to a simplified GDHS which consisits of subsurface systems, surface systems, and transmission/distribution systems, we find out the properties of the system and the model parameters affecting the initial investment/operating costs in order to develop a classical economic feasibility model given geothermal temperature. Based on our model parameter space, we analyzed the geothermal development project of the Jejoo Island probabilistically given prior information such as the expected geothermal power, the demand size and the length of transmission/distribution pipes.

  • PDF

환형용기내 성층화된 유체의 회전효과에 따른 이중확산대류에 관한 실험적 연구 (Double Diffusive Convection of a Stratified Fluid in a Rotating Annulus Due to Lateral Heating)

  • 강신형;전창덕;이진호
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1709-1719
    • /
    • 1995
  • The primary objective of the paper is to obtain the basic information of the natural convection of a stratified with various parametric conditions related to rotating speed, temperature and concentration gradient. For the purpose of it, experiments are performed in a stably stratified salt-water solution with lateral heating in a stationary or rotating annulus. The experiment covers the ranges of Ar=2, Le=100, R $a_{\ta}$=2 10$^{5}$ and Ta=0, 10$^{5}$ - 2.5*10$^{8}$ . Many interesting flow phenomena are observed and rotation effects are examined. Particularly as Taylor number increases (rotation increases) at a given R $a_{\ta}$, the generation of rolls at hot wall is inhibited and the formation and merging process of layers are delayed.

공공건물 중앙식 냉난방시스템의 연간 운영 사례 분석 (Analysis of Annual Operation Status of Central Heating and Cooling System in a Public Office Building)

  • 라선중;엄태윤;손진웅
    • 대한건축학회논문집:구조계
    • /
    • 제36권2호
    • /
    • pp.175-180
    • /
    • 2020
  • The purpose of this study was to clarify precautions during the design and operation phases for energy reduction in a public office building. To check the operation status of the building, we measured the indoor temperature and humidity in the office space of the building installed central heating and cooling systems. And we analyzed these data and annual BEMS data. As a result, we found six problems related to decreasing system efficiency. Based on these, we presented the information to improve the efficiency of the system from the design and operation phase. Also, we present the need for a system to support the decision-making of operational managers in real-time for the energy efficiency of the building.

태양열난방장치 설계를 위한 f-chart 개발 (Development of f-chart for the Design of Solar Heating Systems)

  • 송달순;유성연
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.292-298
    • /
    • 1986
  • The new f-chart capable of estimating long-term thermal performance of solar space and water heating systems was developed. The system comprise a flat plate solar collector, heat exchanger, storage tank filled with water, auxiliary fuel fired heater, and a house structure. The information obtained from many simulations of solar heating systems has been used to develop this f-chart. Actual hourly meteorological data collected in Seoul, Daejeon, Kwangju and Daegu, Korea from 1979 to 1983 have been utilized in these simulations. The new f-equation is as follows: $$f=1.034Y_{-}0.0968X_{-}0.2235Y^2+0.0043X^2+0.0144Y^3$$. The system performance estimates obtained from the developed f-chart are in close agreement with the results of experiment.

  • PDF

오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교 (Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building)

  • 정근주
    • 한국주거학회논문집
    • /
    • 제17권4호
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.