• Title/Summary/Keyword: heating fuel

Search Result 767, Processing Time 0.028 seconds

보일러의 효율향상(效率向上)을 위한 연소보조장치(燃燒補助裝置)에 관(關)한 연구(硏究) (연소실(練燒室) 모형(模型) 실험(實驗)) (A Study on the Apparatus for Improving Boiler Efficiency)

  • 서정일;조진호;이창식;조종미
    • 태양에너지
    • /
    • 제2권2호
    • /
    • pp.11-20
    • /
    • 1982
  • This paper presents the experimental investigations of a system as a second treatment means to increase boiler efficiency and heat transfer from combustion gas to heating surfaces in the case of spray combustion. In order to reburn residual combustible components accelerate the burning rate of sprayed fuel droplets, improve the diffusion flame and delay the residence time of the flame, advice with slit type nozzles for spouting preheated supplementary air is used in this study. In the experiment, boiler efficiency and smoke concentration in the exhaust gas at given conditions are measured in both case of installing and not-installing device in the model of combustion chamber which was designed to be equipped with five surfaces. The results obtained in this experiment are as follows ; 1. The optimum values of air rate ${\lambda}$ are about 1.3 in both case. 2. The exhaust gas temperature in the case with device increases about $30{\sim}70^{\circ}C$ above that of the case without the device. 3. Boiler efficiency and reduction effect of smoke emissions are improved considerably.

  • PDF

Pilot급 산소 MILD 연소에 관한 실험 및 수치해석적 연구 (An Experimental and Numerical Study on the Oxy-MILD Combustion at Pilot Scale Heating Capacity)

  • 차천륜;이호연;황상순
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.275-282
    • /
    • 2016
  • MILD (Moderate and Intense Low-oxygen Dilution) combustion using oxygen as an oxidizer is considered as one of the most promising combustion technologies for high energy efficiency and for reducing nitrogen oxide and carbon dioxide emissions. In order to investigate the effects of nozzle angle and oxygen velocity conditions on the formation of oxygen-MILD combustion, numerical and experimental approaches were performed in this study. The numerical results showed that the recirculation ratio ($K_V$), which is an important parameter for performing MILD combustion, was increased in the main reaction zone when the nozzle angle was changed from 0 degrees to 15 degrees. Also, it was observed that a low and uniform temperature distribution was achieved at an oxygen velocity of 400 m/s. The perfectly invisible oxy-MILD flame was observed experimentally under the condition of a nozzle angle of $10^{\circ}$ and an oxygen velocity of 400 m/s. Moreover, the NOx emission limit was satisfied with NOx regulation of less than 80 ppm.

우리나라 도시지역의 $SO_2$건성침적 플럭스 산출 (Estimations of the $SO_2$Dry Deposition Flux at Urban Areas in Korea)

  • 이종범;김용국;박일환
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2001
  • This study was carried out estimating the dry deposition flux of $SO_2$at eight urban areas in Korea during one year of 1996. To calculate the deposition flux, deposition velocities were calculated by turbulence parameters estimated from routine meteorological data. Also, hourly averaged $SO_2$concentrations which calculated from air pollution monitoring data of each city were used. The dry deposition velocities were mostly higher in the coastal areas than the other areas, which would be caused by relatively strong wind. And, they were high in the daytime because of turbulence activities. The deposition flux of $SO_2$is mainly related to the atmospheric concentration. The annual average $SO_2$concentration and the deposition flux were 22.62ppb and 1510.52g/$\textrm{km}^2$/hr at Pusan respectively. Also, the flux was higher in winter than other season, which was a significant contribution of exhausted fuel for heating. While the deposition velocity was high to 0.688cm/sec at Yosu in case of strong wind and small cloud cover, the deposition flux was high to 1597.4g/$\textrm{km}^2$/hr at Pusan in case of weak wind and small cloud cover.

  • PDF

고체 산화물 연료전지의 열사이클 따른 성능 열화 특성 연구 (A Study on Thermal Cycle Characteristics of Solid Oxide Fuel Cell)

  • 김응용;송락현;전광선;신동열;강대갑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1312-1314
    • /
    • 1998
  • SOFC system is often subject to thermal cycle condition during normal start/stop, shutdown, and emergence state. Under the thermal cycle condition of heating and cooling, the SOFC components expand or shrink, which produces thermal stress and thermal shock. The SOFC performance is degraded by the thermal factors. To protect SOFC system from the thermal degradation, the optimum thermal condition must be clarified. In this study, to examine the thermal cycle characteristics, we fabricated single cells of planar SOFC with an area of $5{\times}5cm$. The electrolyte and PEN were tested under thermal cycle conditions in the range of$ 2-8^{\circ}C/min$. After thermal cycle test. crack creation of the components were examined using ultraviolet apparatus. No crack in the electrolyte and PEN were observed. The single cell system with alumina frame were also tested under thermal cycle conditions of 2, 3, $4^{\circ}C/min$. The single cell was fractured at the thermal cycle of 3 and $4^{\circ}C/min$ and the optimum condition of the thermal cycle to be found below $2^{\circ}C/min$.

  • PDF

LFG 활용을 위한 기초 연소특성 검토 (An Investigation of the Fundamental Combustion Characteristics for the Utilization of LFG)

  • 이창언;오창보;금성민
    • 대한기계학회논문집B
    • /
    • 제28권1호
    • /
    • pp.99-108
    • /
    • 2004
  • Fundamental combustion characteristics, such as the combustion potential, burning velocity and flame stability, for the practical utilization of LFG(Landfill gas) and LFG-blended fuels were experimentally investigated. The combustion potentials(CP) of LFG-blended fuels calculated from the previously suggested formulae were compared with burning velocities obtained by present experiments. The results showed that the previous formulae fur CP of LFG-blended fuels were not agreed with the experimental burning velocity, and these formulae should be revised. To provide an useful information needed to design the combustion devices, a triangular diagram was suggested for the maximum burning velocity of the mixture of CH$_4$, LPG and LFG. From the investigation of the burning velocity and the flame stability in a practical combustor, it was noted that the LFG-blended fuels, of which heating values or Wobbe indices were adjusted to that of natural gas, could be used as an alternative fuel of natural gas.

Preparation and Characterization of Proton Conductive Phosphosilicate Membranes Based on Inorganic-Organic Hybrid Materials

  • Huang, Sheng-Jian;Lee, Hoi-Kwan;Kang, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권2호
    • /
    • pp.241-247
    • /
    • 2005
  • A series of proton conductive inorganic-organic hybrid membranes doped with phosphoric acid ($H_3PO_4$) and/or triethylphosphate (PO(OEt)$_3$) have been prepared by sol-gel process with 3-glycidoxypropyltrimethoxysilane (GPTMS), 3-aminopropyltriethoxysilane (APTES) and tetraethoxysilane (TEOS) as precursors. High proton conductivity of 3.0 ${\times}$ $10^{-3}$ S/cm with composition of 50TEOS-30GPTMS-20APTES-50$H_3PO_4$ was obtained at 120 ${^{\circ}C}$ under 50% relative humidity. Thermal stability of membrane was significantly enhanced by the presence of SiO$_2$ framework up to 250 ${^{\circ}C}$. XRD revealed that the gels are amorphous. IR spectra showed a good complexation of $H_3PO_4$ in the matrix. The conductivity under 75% relative humidity was significantly improved by addition of APTES due to the increase in concentration of defected site in hybrid matrix. The effect of PO(OEt)$_3$, humidifying time, and heat-treatment were also investigated. PO(OEt)$_3$ had no improvement on conductivity and conductivity increased with humidifying time, however, decreased with heating temperature.

Eco-efficiency of Energy Symbiosis for the Energy Network of Surplus Heat

  • Shin, Choon-Hwan;Kim, Ji-Won
    • 한국환경과학회지
    • /
    • 제21권5호
    • /
    • pp.545-553
    • /
    • 2012
  • Eco-efficiency considers both environmental impacts and economic values. It is a useful tool for communicating with stakeholders for business decision making. This study evaluated the eco-efficiency factor (EEF) for the energy network of a dyeing company that supplies surplus heat to a neighboring apartment during the night. This symbiosis network is one of the eco-industrial park (EIP) projects in Korea and aims to benefit local residents and the industrial complex by utilizing surplus heat. In this study, two categories were annualized. The first quantified environmental burden based on $CO_2$ emissions and quantified product value in terms of steam sales. The second used a variety of environmental factors, such as fossil fuel, water and waste, to quantify environmental burden and used steam sales to quantify value. The EEF of the symbiosis network was 1.6, using the global warming impact, and determined using the multiple variable, was 1.33. This study shows that the EEF depends on variable details of environmental burden but the values of this project were very high contrast to other business or EIP project.

청주시 저소득 가구의 가정 에너지 비용 부담 경험과 인식 (Low-income Households' Experiences and Perception of Home Energy Cost Burdens in Cheongju, South Korea)

  • 이현정
    • 한국주거학회논문집
    • /
    • 제26권5호
    • /
    • pp.79-87
    • /
    • 2015
  • This study explored low-income households' experiences and perception of home energy cost burdens and determinants of the perceived home energy cost burdens. Between March and July 2014, a questionnaire survey was administered in Cheongju, South Korea. Among the 434 useable responses collected, responses from 218 households with monthly income less than 2,500,000 Korean Won (KRW) were compared with those of 216 households with higher incomes. The main findings are as follows. In the past three years, more than 10 percent of low-income households had had their electricity cut off; 5.7 percent had had their city gas cut off. To pay for their home energy expenses, nearly 70 percent of the low-income households had had to limit their heating, cooling or spending for other necessities; 38.3 percent had to borrow money. Low-income households reported more problems paying for home energy than higher-income households did. Households with more negative evaluation of rainwater leak, no one staying at home all day, monthly income less than 1,500,000 KRW and householders in their 40s and 50s tended to perceive a heavier home energy cost burden. Finally, the most popular support programs were fuel assistance and discounts on energy bills.

중온형 원통다관형 수증기 개질기의 부분단열 및 반경방향 분배 구조의 영향 (Partial Insulation and Heating Tubes Configuration of Shell and Tube Steam Reformer at Medium Temperature)

  • 박다인;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.618-626
    • /
    • 2017
  • Conventional high temperature reformers are not suitable for hybrid fuel cell systems that use waste heat as a heat source. So, development of a low temperature type reformer is needed. However, the analysis was conducted in two ways to increase the thermal efficiency, because of low reforming rate due to the low heat source. First, it is a way to ger thermal gain from the outside through partial insulation. In the case of one heat source tube and several heat source tubes, we analyzed the effect of partial heat insulation in some cases. Second, we found the most efficient arrangement of the heat source tubes by changing the location of the heat source tubes. The interpretation was carred out using the COMSOL Mutiphysics program.

저온형 고체산화물 연료전지를 위한 20mo1% Gd-doped $CeO_2$ 전해질의 제조에 관한 연구 (Preparation of 20mol% Gd-doped $CeO_2$ Electrolyte for the Low-Temperature Solid Oxide Fuel Cells)

  • 김선재;황종선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.305-307
    • /
    • 1997
  • Gd-doped $CeO_2$, ultrafine powders were synthesized by the glycine-nitrate process and then their sintering and electrical characteristics were analysed using the dilatometric and AC impedance measurements. In the dilatometric measurements green bodies from the synthesized powders after milling shrinked to about $1470^{\circ}C$ in appearance and then expanded thermally with the increase of the heating temperature, whereas those from the synthesized powders before milling continuously shrinked to the temperatures of $1600^{\circ}C$. It may be due to the change of the packing density of the synthesized powders by milling. In the AC impedance measurements, the electrical resistivity of the Gd-doped $CeO_2$ bodies from the as-milled powders, sintered at $1500^{\circ}C$ with the increase of the sintering time, showed the minimum value at the sintering time of 10h. The minimum total resistivity of the Gd-doped $CeO_2$ bodies sintered at $1500^{\circ}C$ for 10h seems to result from the lowest activation energy by the combination between the activation energies for the resistivities at the grain interior and grain boundary.

  • PDF