• Title/Summary/Keyword: heating experiment

Search Result 868, Processing Time 0.029 seconds

A study on the Measurement of the Coefficient of Thermal Expansion of Polymer materials Exposed to Different Thermal Environments (서로 다른 열환경에 노출된 고분자 소재의 열팽창계수 측정에 관한 연구)

  • Kim, Dong-Ju;Park, Seul-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.80-86
    • /
    • 2021
  • Plastics are widely used in mechanical and other fields due to their light weight, design flexibility, and molding processability. In processing plastics, defective products are mixed and reprocessed to improve production efficiency and reduce costs. In this study, an experiment was conducted to confirm the coefficient of thermal expansion of HDPE during this reprocessing. The coefficient of thermal expansion was measured at different measurement directions and heating rates. As a result, we observed that the coefficient of thermal expansion in the direction perpendicular to the injection direction is greater than that in the horizontal direction.

Verification Experiment and Calculation of Cooling Load for a Test Space (시험공간에 대한 냉방부하 실증실험 및 계산)

  • 유호선;현석균;김용식;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.641-651
    • /
    • 2003
  • In order to assess the reliability of a building energy simulation program (TRNSYS) from the standpoint of user, a set of verification experiment and calculation of cooling load for a test space is carried out. This work is a complement of the previous study that dealt with heating load for the same space. The test space is kept airtight to eliminate the source of uncertainties in modeling. A window-mounted, on/off controlled air-conditioner is used for cooling, whose performance has been established a priori. The calculation encompasses two models for evaluating cooling load in TRNSYS: energy rate control and temperature level control. Comparison of the total cooling loads obtained from different sets of experimental data enables to validate the measurements. The experimental result shows that the latent load is fairly large even in the absence of apparent air change in the space, which needs to be clarified. Each of hourly and daily accumulated sensible loads is compared between the experiment and two calculation models. Despite an inconsistency associated with solar irradiation, both of the models agree favorably with the experiment within a tolerance, illustrating their capability of properly predicting space thermal loads.

Effects of Covering Materials and Methods on Heat Insulation of a Plastic Greenhouse and Growth and Yield of Tomato (플라스틱하우스의 보온피복 재료 및 방법이 보온력과 토마토의 생육 및 수량에 미치는 영향)

  • Kwon Joon Kook;Lee Jae Han;Kang Nam Jun;Kang Kyung Hee;Choi Young Hah
    • Journal of Bio-Environment Control
    • /
    • v.13 no.4
    • /
    • pp.251-257
    • /
    • 2004
  • This experiment was carried out to investigate the effects of different covering materials and methods on heat insulation of a plastic greenhouse, growth and yield of tomato. Night air and soil temperatures in a double-layer greenhouse with external multifold thermal cover (MTC; eight-ounce cassimere+four-fold polyform+double-fold non-woven fabric+single-fold polypropylene covering were about $1^{\circ}C$ lower than in that with internal MTC covering, but about $3^{\circ}C$ higher than in that with an EVA film screen. Tomato yield in the external MTC covering increased by $2\%\;and\;19\%$ as compared to that in the internal MTC covering and the non-covering of MTC, respectively, due to its high light transmission and insulation effect. Night air temperatures in a double-layer greenhouse with external MTC covering and with thermal screen (polyester plus aluminium) were $2.2^{\circ}C\;and\;4.5^{\circ}C$ higher than those in a double-layer greenhouse with an external MTC covering and in a double-layer greenhouse equipped an EVA film screen, respectively. Tomato yield in the treatment with external MTC covering and a thermal screen was $18\%\;and\;37\%$ greater than that in the external MTC covering and in an EVA film screen, respectively. Results indicate that tomato could be grown without heating or with minimal heating in a double-layer greenhouse covered with MTC and a thermal screen during the winter season in sourthern regions of Korea.

Study on the Thermal Characteristic Comparison of Fire.Explosion Hazard of Fugitive Dust Generated in the Manufacturing Process (제조공정상 발생하는 비산분진의 화재·폭발 위험성에 대한 열적특성 비교에 관한 연구)

  • Sun, Ko Jae
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.71-83
    • /
    • 2014
  • This study carried out an experiment in order to compare thermal characteristics after collecting dust generated in the process of disposing of waste tire, plywood flour in the process of manufacturing plywood, salicylic acid dust in the process of manufacturing functional soap, and dust in the process of manufacturing wheat powder, which has potential fire and explosion hazard. According to the results of experiment, the analysis showed that all samples subject to the experiment were in the condition where heat flux decreased and temperature decreased as the quantity of added talc was increased. This shows that decomposition rate decreased, and hazard decreased. However, in all of samples subject to the experiment, as heating rate increased, endothermic onset temperature moved to the low-temperature part, and the amount of absorbed heat was largely increased. This showed that the decomposition hazard of sample increased as heating rate increased, according to the analysis. Besides, TGA experiment results showed that thermal stability was secured because total weight loss decreased as the amount of talc was increased for all samples subject to the experiment regarding the ratio of weight loss. It is expected that the continuous research and supplementation of dust explosion mechanism in the future will contribute to the establishment of measures for the effective dust explosion prevention.

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

The Experimental Study of Various Salts on the Characteristics of Heat Transfer in Indirect Moxibustion with Salt (염(鹽)의 종류(種類)에 따른 격염구(隔鹽灸)의 열전달(熱傳達) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Lee, Geon-mok;Lee, Gun-hyee;Seo, Eun-mi
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.119-135
    • /
    • 2004
  • Objective: The purpose of this study is to investigate the mechanism and effect of moxibustion with salt objectively, to be used as the quantitative data through the measurement of temperature, and to grasp the thermodynamic characteristics of moxibustion with salt. Methods: We have selected of the moxibustion with salt of indirect moxibustion. We make a comparative study of the thermodynamic characteristics of moxibustion with salt as a kind of the 4 salt. We examined combustion times, temperatures, temperature gradients in each period during a combustion of moxa. Results: 1. We make out that it is not significantly change the time of thermal conduction of moxibustion with salt as a kind of 4 salt. 2. The heating period of Refined Salt was long and that of Sun-dried Salt was a short time respectively. The heating period of maximum tamperature is high Sun-dried Salt, Mechanical Salt and Refined Salt orderly. Maximun heating speed in the heating period was $0.151{\sim}0.184^{\circ}C/sec$ and at the same tendency of the maximum temperature in the heating period. 3. The retaining period was shorter than the heating period respectively, that is 15~24% of the combustion time of in the heating period. We make out that it is not significantly different the time of the retaining period as a kind of 4 salt. The mean temperature of retaining period was $43.2{\sim}48.1^{\circ}C$, that was extraordinarily high temperature. 4. We make out that it is not significantly different the time of the cooling period as a kind of 4 salt. The cooling period was measured 223~233sec. Beacuse the same density and size of moxa combustion was made an experiment. 5. The effective combustion time of Refined Salt is longer(259sec) than that of Sun-dried Salt(173sec). It is significantly different the time of the combustion time as a kind of 4 salt. 6. It is significantly different the Sample deviation of the combustion time as a kind of 4 salt because of the water content of the 4 salt individually. Conclusions: As the base on this study, we obtained the conclusion as the follows. The salt of moxibustion with salt was fitted for Sun-dried Salt due to making to Mechanical Salt recently. The Refined Salt is composition rate to another and small size comparatively. So It was fitted for the salt of moxibustion with salt. It is necessary to study continuously about the more suitable moxibustion with salt and quantitative analysis about the moxibustion with salt.

  • PDF

Study on the Effect of Season Conditions to the Performance of Longitudinally-Finned Air-Heating Vaporizer

  • Djajadiwinata, Eldwin;Lee, Yong-Hun;Kim, Pil-Hwan;Park, Gi-Tae;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2321-2326
    • /
    • 2007
  • To return LNG to a gaseous state, it is fed into a regasification plant. For inland area, where pipelines do not exist or difficult to construct, the LNG is delivered to the inland-receiving terminal available at that area, regasified and delivered to consumers. At inland-receiving terminal, air-heating vaporizer type is usually used. To contribute in developing an efficient air-heating vaporizer, experiment on finned type air-heating vaporizer using 8 fins, 50 mm fin length (8fin50le) and 4 fins, 75 mm fin length (4fin75le) were conducted. The experiments were conducted by varying the ambient condition and the length of the vaporizer. The ambient air was controlled so that it has the same condition with air condition in every season available. $LN_2$ is used to substitute LNG because of safety reason. The results show that characteristics of the finned type 4fin75le vaporizer are comparable to finned type 8fin50le vaporizer at all season.

  • PDF

Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump (여과수열원 히트펌프를 이용한 온실난방기술 개발)

  • Moon, J.P.;Lee, S.H.;Kang, Y.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

Simulation Study on the Effects of Heating Rate and Particle Size Distribution for the Formation of the Agglomerate During CWM Combustion (CWM 연료의 연소시 입자 가열속도와 입자 크기가 CWM 응집물 형성에 미치는 영향에 관한 전산모사 연구)

  • Kim, Soo-Ho;Kim, Young-Hwan;Hwang, Kap-Sung;Hong, Song-Sun
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.364-371
    • /
    • 1998
  • A theoretical model of particle agglomeration was developed to investigate the adhesive force between contiguous coal particles in CWM agglomerate. While heating bituminous coal to about $400^{\circ}C$ or above, the transient occurrence of plastic behavior of coal particles can be observed. The adhesive force in the process of agglomeration of coal particles was found to be proportional to the duration of plasticity of the particles. In the research, how the heating rate and the particle size distribution of CWM fuel influenced the formation of the agglomerate in CWM fuel at the heat-up stage was investigated by the model of particle agglomeration. Simulation program used to this experiment was RKG method and was programmed by Fortran. It was represented that by the model of particle agglomeration, the adhesive force in the process of the particle agglomeration in CWM fuel was inversely proportional to the heating rate but proportional to particle size.

  • PDF

Development of a Cooling and Heating System for Greenhouse using Geothermal Energy (지열을 이용한 온실용 냉난방시스템 개발)

  • Lee Yong-Beom;Cho Seong-In;Lee Jae-Han;Kim Tae-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF