• 제목/요약/키워드: heating experiment

검색결과 868건 처리시간 0.027초

친수 표면처리 종류에 따른 공기 예열 열교환기의 응축 열전달 실험적 연구 (Experimental Study of Condensation Heat Transfer in Pre-heating Exchanger to the Type of Hydrophilic Surface Treatment)

  • 석성철;정태용;신동훈;황승식;최규홍;박재원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.237-238
    • /
    • 2012
  • Recently, an energy-saving due to the energy utilisation efficiency enhancement is important. In order to improve the heat efficiency of the general residential boiler, We performed an experiment of condensation heat transfer to air pre-heat exchanger adhered to the condensing boiler. In this research, We analyze the heat transfer performance through the hydrophilic surface treatment(plasma, etching). The results of the research, On plasma and etching treated surface, Overall heat transfer coefficient is displayed the tendency to increase.

  • PDF

배합률의 변화에 의한 MORTAR의 초음파 흡수현상 (A Study on the Absorption Phenomena of Ultrasonic Exergy in the Mortar with different Mixing Ratio of Sand to Cement)

  • 전춘생;홍봉식
    • 전기의세계
    • /
    • 제25권6호
    • /
    • pp.74-80
    • /
    • 1976
  • The temperature rise of the mortars while are being irradiated by ultrasonic waves and immersed in a liquid medium, are measured. The mixing ratios of sand to cement are varied for the different mortars. The results of the experiment are as follows, 1. The temperature rise of the mortar is decreased as themixing ration (S/C) is increased. 2. Thd temperature rise of the specimen is increased as its length is increased. 3. The surface conditions, either smooth or rough, may not have much influence on the temperature rise of the mortar. 4. The initial slope of temperature rise may not have much effect of the viscosity of liquid. The results, describes above, appear well coincide with the theory that the temperature rise is attributed mainly to the absorption heating. Since the absorption heating of the mortars varies with the mixing ratios of sand to cement, the strength of them would be estimated by means of irradiation of ultrasonic waves on the specimen.

  • PDF

유공압 밸브스풀용 Cr-Mo 강봉의 동종재 마찰용접과 AE평가 (Friction Welding of Cr-Mo Steel Bars for Hydraulic of Pneumatic Valve Spools and AE Evaluation)

  • 오세규;장지훈
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.103-112
    • /
    • 1995
  • This study was performed to optimize friction welding conditions of Cr-Mo steel bars used for hydraulic of pneumatic valve spools and to realize the real-time evaluation of weld quality by acoustic emission method. SNCM220, SCM435, SCAM645, and SCM415 steel bars were tested to find optimum conditions of friction welding. Auantitative equations which exhibit the relations of tensile strength, elongation, reduction of area and energy absorption with friction heating time were obtained by the experiment. Acoustic emission was also performed in the friction weldig process, and the real-time evaluation was enabled to find the optimum range of weld strength. Finally, the strength and toughness of welded joints were interpreted by the sem analysis of tensile fracture surfaces.

  • PDF

공동주택 거실의 냉방방식에 따른 열환경 특성에 관한 연구 (A Study on the Characteristic of the Thermal Environment in the Cooling System at the Apartment)

  • 이무진
    • 한국주거학회논문집
    • /
    • 제10권4호
    • /
    • pp.111-120
    • /
    • 1999
  • The purpose of this study is to evaluate the efficiency of the thermal environment created by the cooling system at the apartment that combines the forced convection cooling(the system reducing humidity from room) with the floor cooling radiation which uses the floor panel from floor heating system, a general residential heating system in Korea. In this study, the combined cooling system in which air supply, spurt temperature difference and interior draft are reduced, is compared with the existing forced convection cooling system. To identify the effect of the comparison concretely, a comparative experiment is carried out on tour conditions, ie, convection cooling, floor radiation convection cooling and floor radiation cooling. Through it the characteristical thermal environment formed within the model room is analyzed, and the conveying system of compressed floor chill and condensation problem are reviewed.

  • PDF

Pilot규모에서 계면활성제용액의 장기 마찰저항감소에 관한 연구 (Long term drag reduction experiments of surfactant solutions in a pilot-scaled system)

  • 박성룡;이상남;문승현;윤형기
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.401-409
    • /
    • 1997
  • The long term drag reduction characteristics of Habon-G solution were investigated in the KIER pilot-scaled district heating simulation system. Test runs were implemented for 30 days without interruption. Pressure drop, flow rate and power consumption of surfactant (Habon-G) solution were regularly observed and compared with those of plain water. The experimental results suggest that the surfactant can be effectively applied to the DH transmission system for considerably long period wthout significant loss of its drag reduction capability even though the concentration of the additive may gradually decrease in the first stage of the experiment because of absorption.

  • PDF

SM45C의 연속파형 Nd:YAG 레이저 용접시 발생하는 기공과 결함의 감소 (Decrease of Porosity and Cracking in the cw Nd:YAG Laser Welding of SM45C)

  • 유영태;오용석;노경보;신호준;임기건
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.65-73
    • /
    • 2003
  • The effect of pre-heating on the mechanical properties of laser welding joints has been investigated for the case of SM45C carbon steel welded by a cw Nd:Y AG laser. The occurrence of porosity and cracking was inspected in various welding conditions to find the optimal welding parameters. The results of laser welding experiment with pre-heating technique showed that porosity and cracking can be reduced significantly in most of welding conditions and the welded joints have improved mechanical properties, such as higher tensile strength and better durability.

Aeration Control of Thermophilic Aerobic Digestion Using Fluorescence Monitoring

  • Kim, Young-Kee;Oh, Byung-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권1호
    • /
    • pp.93-98
    • /
    • 2009
  • The thermophilic aerobic digestion (TAD) process is recognized as an effective method for rapid waste activated sludge (WAS) degradation and the deactivation of pathogenic microorganisms. Yet, high energy costs due to heating and aeration have limited the commercialization of economical TAD processes. Previous research on autothermal thermophilic aerobic digestion (ATAD) has already reduced the heating cost. However, only a few studies have focused on reducing the aeration cost. Therefore, this study applied a two-step aeration control strategy to a fill-and-draw mode semicontinuous TAD process. The NADH-dependent fluorescence was monitored throughout the TAD experiment, and the aeration rate shifted according to the fluorescence intensity. As a result, the simple two-step aeration control operation achieved a 20.3% reduction in the total aeration, while maintaining an effective and stable operation. It is also expected that more savings can be achieved with a further reduction of the lower aeration rate or multisegmentation of the aeration rate.

이중 취출구에 의한 온풍난방시의 열환경 개선 (Improvement of Thermal Enviromental by Two Air Out in Hot Air Heating)

  • 장인성;김종수
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.209-217
    • /
    • 1997
  • The objective of this paper is to improve a discomfort caused by the unequal airflow and vertical temperature difference by buoyancy of the supplied hot air in the conventional hot air heating system. In order to the model experiment we manufactured the hot air heater with two air outlet and a model room. We observed the temperature, velocity and airflow distribution and calculated values of PMV and PPD using mean value of central verticality section's air temperature and velocity. We could improve distribution of vertical temperature and velocity at the central section of the model room owing to correlation of hot air of two air outlet.

  • PDF

Ar의 녹는점에 관한 분자동역학적 고찰 (Study on the Melting Point of Ar by Molecular Dynamic Simulation)

  • 정재동
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.883-888
    • /
    • 2007
  • As a starting point of investigating what molecular dynamic simulations can reveal about the nature of atomic level of heating and cooling process, argon described by the LJ potential is considered. Stepwise heating and cooling of constant rates are simulated in the NPT (constant number, pressure and temperature) ensemble. Hysteresis is found due to the superheating and supercooling. Drastic change of volume and energy is involved with phase change, but the melting point can not be obtained by simply observing the changes of these quantities. Since liquid and solid phases can co-exist at the same temperature, Gibbs free energy should be calculated to find the temperature where the Gibbs free energy of liquid is equal to that of the solid since the equilibrium state is the state of minimum Gibbs free energy. The obtained melting temperature, $T^*=0.685$, is close to that of the experiment with only 2% error.

Tapered Lens를 사용한 Light Source와 Optical Fiber의 고효율 Coupling (A Highly Efficient Method of Light Coupling into Optical Fiber with a Tapered Microlens)

  • 이상호;강민호
    • 대한전자공학회논문지
    • /
    • 제16권4호
    • /
    • pp.22-26
    • /
    • 1979
  • LED나 laser diode와 optical fiber의 coupling efficiency를 높이기 위해서는 lens의 곡율반경을 작게 하는 것이 효과적이다. 본 연구에서는 heating and pulling 반경에 의한 tapered lens를 고안함으로써 최적 size의 lens 제작을 용이하게 하였으며, taper의 특성을 이용하여 고효율 coupling을 가능하게 하였다. 이론적 계산에 의하여 90%까지의 light coupling이 가능함을 보였으며, 실험결과 flat end에 대한 improvement factor는 LED에서 3dB, laser diode에서 6dB까지 증가시킬 수 있었다. epoxy를 사용하여 LED에 pigital을 부착한 결과 온도특성 및 기계적 안정성에서 실용화에 충분할 정도로 우수하였다.