• Title/Summary/Keyword: heating experiment

Search Result 868, Processing Time 0.025 seconds

Study on Natural Convection in a Rectangular Enclosure With a Heating Source

  • Bae, Kang-Youl;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.294-301
    • /
    • 2004
  • The natural convective heat transfer in a rectangular enclosure with a heating source has been studied by experiment and numerical analysis. The governing equations were solved by a finite volume method, a SIMPLE algorithm was adopted to solve a pressure term. The parameters for the numerical study are positions and surface temperatures of a heating source i.e., Y /H =0.25, 0.5, 0.75 and 11$^{\circ}C$ $\leq$ΔT$\leq$59$^{\circ}C$. The results of isotherms and velocity vectors have been represented, and the numerical results showed a good agreement with experimental values. Based on the numerical results, the mean Nusselt number of the rectangular enclosure wall could be expressed as a function of Grashof number.

The Experimental Consideration for Extermination of a Rice Weevil in Grain by Dielectric Heating Apparatus (유전가열장치에 의한 곡물 바구미 구제의 실험적 고찰)

  • Han, K.H.;Kim, T.J.;Joe, K.Y.;Lee, H.W.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.257-259
    • /
    • 2002
  • With development of Circuit technology, accuracy of dielectric or induction heating apparatus was developed. This study aims at realization of food insecticidal apparatus using dielectric heating. Equipment to measure grain's permittivity or vermin's permittivity and expectation for heating temperature by computer simulation is necessary for construction of the system. And the effect of extermination of vermin for food was confirmed by experiment using the system.

  • PDF

Numerical & Experimental Study For Burner of Low NOx Formation of Multi-Stage In a Combustor (연소기에서의 다단 저 NOx 버너의 수치 및 실험적 연구)

  • Choi, Yun-Ki;Kang, Kyung-Tae;Kim, Young-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.65-74
    • /
    • 2003
  • Air pollution included Nitric Oxide(NOx) from heating boilers is increased by pursuing better life. Development of low NOx emission boiler is strongly needed. However commercial burner for heating boiler is also asked to be thermal efficient and low-cost manufactuable in addition to low NOx emission. Small space for combustor including burner is usually allowed. In this study, parametric study of compact low NOx burner for heating boiler was done using numerical analysis and experiments. Commerical computational fluid dynamic(CFD) program named CFX 5-6 was used for numerical analysis of low NOx burner using turbulent diffusion flame. Comparison of outlet NO and outlet temperature under various equivalence ratio and fuel flow rate was performed between experiment and numerical analysis.

  • PDF

Application Study on the Outdoor Air Temperature Prediction Control for Continuous Floor Heating System (연속바닥난방시스템에 대한 외기예측제어적용 연구)

  • 태춘섭;조성환;이충구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.836-844
    • /
    • 2001
  • For the radiant floor heating system, the possibility of suboptimal prediction control was investigated by computer simulation and experiment. For this study, TRANSYS program was used and an experimental facility consisting of two rooms (3$\times$4.4$\times$2.8m) was built. The facility enabled simultaneous comparison of two different control strategies which implemented in a separate room. Results showed that outdoor air temperature prediction control was superior to the conventional outdoor air temperature compensation control for radiant floor heating system. However, more research for fine prediction of outside air temperature was required in the future.

  • PDF

Thermal Performance Assessment of Wet Ondol and Electric Ondol System (습식온돌시스템과 전기온돌시스템의 열성능 평가)

  • Han, Byung-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

An Experimental Study on the Control Methods of Radiant Floor Heating Systems (바닥복사 난방시스템의 제어방식에 관한 실험적 연구)

  • 김오봉;이진영;여명석;석호태;김광우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1297-1305
    • /
    • 2001
  • In this study, existing control methods that are suggested or applied until now are classified by control parameters, and stability of in the room and floor surface temperatures of each control method is compared through experiments. Then, the control performance of these control methods are analyzed to evaluate the applicability to Korean apartment housing. From the result of the applicability analysis, the outdoor reset with on/off PWM control is found to be desirable for district heating systems and flux modulation is found to be applicable for decentralized heating systems. In the case of independent control systems for each room, on/off PWM control is desirable.

  • PDF

A Study on the Suggestion of Thermal Comfort Range in Radiant Floor Ondol Heating System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.108-112
    • /
    • 2004
  • The purpose of this study is to investigate the characteristics of thermal comfort index and to present the thermal comfort range through regression analyses and experiment in a radiant floor heating system laboratory. The results were compared to the comfort zone of ISO-7730, and the applicability of the thermal comfort index to a radiant floor heating system was studied. On comparing the sedentary posture on the floor to sitting on the chair, the comfort zone and the neutral point of comfort index showed different values. It is considered that the influence of conduction from floor to the human is sufficient. Moreover, we could find a correlation between the thermal sensation votes of subjects, and the comfort indexes were lower than those by calculation.

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Won, Jong-Seo;Lee, Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

Resonant Network Design and Verification of Induction Cooker for Heating Nonmagnetic Vessel (비자성체 용기 가열을 위한 Induction Cooker 공진 네트워크 설계 및 검증)

  • Jang, Eun-Su;Park, Sang-Min;Joo, Dong-Myoung;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.504-509
    • /
    • 2017
  • This paper proposes a procedure for designing a resonant network for induction cookers that enables the induction heating of magnetic and non-magnetic vessels. In order to design such network, the range of operating frequency must be determined according to the material of the vessels by measuring several parameters, such as equivalent resistance and inductance, which are reflected in the working coil of the vessels. Through this process, the capacitance of the resonant capacitor is determined. The PSIM simulation and experiment results verify the feasibility of the proposed design and the heating performance of the designed resonant network.

A Study on the Individual Room Control of Radiant Floor Heating System in Apartment Buildings (공동주택에서 바닥복사 난방시스템의 실별 제어에 관한 연구)

  • 김오봉;이미경;김광우;여명석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.421-429
    • /
    • 2004
  • In Korea, the radiant heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. According to the recent improvement of living standard of residential buildings, the requirement of the thermal comfort and energy saving in heating system has been raised. Until now, the radiant floor heating system has been controlled by room thermostat installed in the living room, but for better thermal comfort, an individual room control method is adopted as an alternative. Therefore, it is necessary to evaluate the control performance between the current control method and the individual room control method. In this study, the control performance between the two systems is evaluated through the field experiment. And the control performances of room air temperature and energy performances are analyzed through the simulation using TRNSYS. Firstly, the simulations are performed in the various outdoor conditions and the flow rates and the simulation results are analyzed for the control performances. Also, to evaluate the energy performance, the simulations are performed under the operating conditions in which the set-point of the room air temperature is fixed or changed according to the schedule of occupancy, and the simulation results are analyzed between the two methods.