보온터널 난방을 위한 온수난방용 코일튜브 열교환기의 열전달 특성 (Heat Transfer Characteristics of Coil Tube Heat Exchanger for Hot Water Heating of Greenhouse Thermal Tunnel)

  • 유영선;강금춘;김영중;백이;강연구;이형모
    • Journal of Biosystems Engineering
    • /
    • 제31권5호
    • /
    • pp.430-435
    • /
    • 2006
  • Greenhouse horticulture in South Korea covered about 52,000 ha in 2005. Greenhouse area of about 12,000 ha has been heated during winter season with heating cost of $20{\sim}40%$ of total Production cost. Farmers engaged in greenhouse horticulture were changed into aged people. Therefore the laborsaving of working process and the saving of greenhouse heating cost should be accomplished simultaneously to increase income of greenhouse horticulture. The best method for saving of greenhouse heating cost is to install thermal tunnels into greenhouse. Then hot air heaters using fossil fuel should be changed into hot water heaters. In other words air heating using forced convection should be changed into natural convection system. In this research coil tube made of flexible PE pipe was designed as hot water heat exchanger and its heat exchanging characteristics were analyzed. This new heat exchanger has been adopted as a natural convection system for hot water heating of greenhouse horticulture.

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교 (A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode)

  • 김용기;이태원;강성주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF

복사난방용 유량조절 밸브의 작동특성 연구 (Operating Characteristics of the Flow Control Valve for the Radiant Heating System)

  • 표진수;장춘수;최광석;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.552-557
    • /
    • 2007
  • Due to the recent improvement of living standard of residential buildings, the requirements of the thermal comfort and energy saving in heating system have been raised. The radiant floor heating system has been widely used as a residential heating method, which has been modernized to use hot water running into the tubes embedded in the floor structure. The uniform flow distribution is very important factor for a radiant floor heating system such as a blood vessel system in human body. Therefore, it is necessary to investigate the operating characteristics to develop an optimal radiant floor heating system. In this study, numerical analyses were carried out, using a commercial CFD code, FLUENT, to obtain the velocity distribution under steady, three-dimensional, standard k-$\varepsilon$ model and no-slip condition. Results are graphically depicted with various parameters.

  • PDF

PWM 방식과 인버터 방식을 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(난방저온 특성) (Experimental Study on Performance Evaluation of System A/C using PWM or Inverter Method (Heating Characteristics at Low Temperature Conditions))

  • 김대훈;전용호;권영철;이윤수;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.551-556
    • /
    • 2003
  • The present study concerns an experiment on the heating characteristics of a system air-conditioner (A/C) using PWM method or inverter method at low temperature con-ditions. The compressors used are digital scroll type and BLDC inverter type. Under the low outside temperature condition, -5$^{\circ}C$, -1$0^{\circ}C$, -15$^{\circ}C$, heating capacities and COPs are mea-sured by the psychometric calorimeter using air enthalpy method. Also, outlet air temperatures at heating operation mode are measured at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$. Experimental results show that COPs of the system A/C using a PWM method are more effective than those of the inverter method at heating operation mode. Although the heater is on, COPs of PWM method are similar to those of BLDC inverter method. Moreover, the heating capacities of PWM method at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$ are larger about 10~20% and outlet air tempe-rature at -15$^{\circ}C$ is larger about 10%, compared to the inverter method.

Research on flow characteristics in supercritical water natural circulation: Influence of heating power distribution

  • Ma, Dongliang;Zhou, Tao;Feng, Xiang;Huang, Yanping
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1079-1087
    • /
    • 2018
  • There are many parameters that affect the natural circulation flow, such as height difference, heating power size, pipe diameter, system pressure and inlet temperature and so on. In general analysis the heating power is often regarded as a uniform distribution. The ANSYS-CFX numerical analysis software was used to analyze the flow heat transfer of supercritical water under different heating power distribution conditions. The distribution types of uniform, power increasing, power decreasing and sine function are investigated. Through the analysis, it can be concluded that different power distribution has a great influence on the flow of natural circulation if the total power of heating is constant. It was found that the peak flow of supercritical water natural circulation is maximal when the distribution of heating power is monotonically decreasing, minimal when it is monotonically increasing, and moderate at uniform or the sine type of heating. The simulation results further reveal the supercritical water under different heat transfer conditions on its flow characteristics. It can provide certain theory reference and system design for passive residual heat removal system about supercritical water.

Prediction of Transient Slab Heating Characteristics in a Walking Beam Type of Reheating Furnace

  • Han Sang-Heon;Baek Seung-Wook
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.405-407
    • /
    • 2006
  • A full-scale simulation of steel mill reheating furnace was performed by using parallel computing technology. Turbulent flow as well as chemical reaction is considered and solved in a coupled manner while radiation is also calculated. The movement of slab is taken into account so that a more precise observation of its heating characteristics becomes possible through this numerical analysis.

  • PDF

간접가열 유화설비에 의한 폐멀칭비닐의 연료유 특성 (Fuel Oil Characteristics of Mulching Waste Vinyl by Indirect Heating Emulsion System)

  • 김해지;김남경
    • 한국기계가공학회지
    • /
    • 제8권1호
    • /
    • pp.37-42
    • /
    • 2009
  • This paper describes the fuel oil characteristics of mulching waste vinyl by indirect heating emulsion system. For the emulsion experiment of waste vinyl, the system is composed of melting furnace, the 1th pyrolysis furnace, and the 2nd pyrolysis furnace. The mulching waste vinyl is used for the fuel oil characteristics analysis of mulching waste vinyl. The refined oil, gasoline, and diesel oil are extracted and quantified to analysis the fuel oil characteristics. From the results of experiments, it has been shown that the production of fuel oil from mulching waste vinyl is possible using the emulsion system.

  • PDF

공동주택의 관리비 추정모델 연구 (A Study on the Maintenance Cost Estimation Model of the Apartment Housing)

  • 이강희;양재혁;채창우
    • 한국주거학회논문집
    • /
    • 제21권2호
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.

PCB-BOARD의 방열기 발열특성 해석 (Heat Characteristics Analysis of Radiator for PCB-Board)

  • 장성철;권민수;한수민
    • 동력기계공학회지
    • /
    • 제20권6호
    • /
    • pp.20-26
    • /
    • 2016
  • For power electronic devices, the thermal energy density per unit volume has seen a rapid increase in recent years, owing to the miniaturization and dense integration of electronic components, as well as the continuous development in performance and function. This research examined the validity and reliability of a thermal safety model for managing the heating conditions of TRIAC electronic components. Among the electronic components of a PCB, these can be considered as a heat source. Using the model, the heating conditions of TRIAC components were maintained at their design target levels in the process of developing an LMT motor drive board. In addition, the heating characteristics of the entire PCB were analyzed to verify its thermal safety. Finally, the reliability and validity of the thermal safety model for maintaining the heating conditions of the TRIAC electronic elements at adequate levels was verified using a numerical analysis method.