• 제목/요약/키워드: heating and cooling air condition

검색결과 100건 처리시간 0.026초

고층빌딩 연돌 현상의 영향인자 분석 (Analysis of impact factors affecting on the stack effect in high-rise building)

  • 오진환;송두삼;윤성민;남유진
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: Recently, high-rise buildings are popular in korea due to high rate of land usage and cost performance in urban area. However, high-rise building causes several problems such as safety issues, cooling/heating load, stack effect, disaster prevention etc. The stack effect is one of the representative problems. Even though there are many researches on stack effect, there are few studies on design guideline considering local condition. Method: This study focuses on the change of pressure distribution according to the design factors which affects the airflow in high-rise residential buildings by simulation analysis. In this study, city, building floor, stairwell door leakage area, elevator door leakage area and changes of layout were considered ad the design factor. Result: The simulation results indicate that building height and ambient air temperature are significant design factor for stack effect.

지하수 이용을 위한 열교환기 개발. II - 지하수이용 냉·난방기 설계제작 - (Development of heat exchanger for underground water heat. II - Design and manufacture for heat exchanger of underground water -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.128-137
    • /
    • 2002
  • 개발된 알루히트를 이용하여 지하수 이용 열교환기를 개발하였다. 시작기는 600mm, 700mm 알루히트 19개의 끝을 U자 용접을 하여 지하수가 직렬흐름이 되도록 2가지로 제작하였다. 성능시험은 개방된 공간에서 지하수 유량과 공기양의 변화를 주면서 상온에서 실시하였다. 1. 시작기의 열전달 계수는 33~156(W/m2℃) 범위로 나타나 설계가정 값에 잘 일치하는 것으로 판단되었다. 2. 열전달 면적이 증가할수록, 지하수 입·출구의 온도 차이가 클수록, 공기의 입·출구 온도 차이가 클수록, 또 송풍량이 증가할수록 에너지 전달량이 증가하였다. 3. 지하수 입·출구 온도 차이가 6℃ 이고 송풍량이 6,000m3/h일 때 전달 열용량은 6,825W였으며, 공기의 입·출구 온도 차이는 25.8℃에서 23.2℃로 -2.6℃의 강화 효과가 있었고, 대류열전달계수는 88.5W/m2℃ 였다. 4. 지하수 입·출구 온도 차이가 2℃ 이고 송풍량이 4,000m3/h일 때 전달 열용량은 2,625W으로 작았지만, 공기의 입·출구 온도 차이는 27℃에서 22.5℃로 -4.5℃의 강화 효과가 있었고, 대류열전달계수는 33.6W/m2℃였다. 5. 시작기 I, II, III의 전달 열용량 데이터 각각의 상관계수 R2은 0.9141, 0.8935, 0.9393이었으며, 공기유량이 6,000m3/h, 5,000m3/h, 4,000m3/h일 때 각각의 데이터 상관계수 R2은 0.9513, 0.9414, 0.9003으로 신뢰할 수 있었다.

기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구 (An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N)

  • 오세규
    • 수산해양기술연구
    • /
    • 제14권2호
    • /
    • pp.79-87
    • /
    • 1978
  • 기관밸브용접 SCr4-21-4N 및 SUH3-21-4N을 연구선정된 최적마찰압접조건 하에서 마찰압접을 하고 이때 생기는 압접부의 잔류응력 및 경도의 peak 등 압접결함의 제거 및 압접성능개선을 위한 열처리에 관하여 실험연구한 결과 다음과 같은 결론을 얻었다. (1) 배기 valve용강 SCr4-21-4N 및 SUH3-21-4N의 마찰압접을 위한 최적조건으로서 회전수 3,000rpm, 마찰가열압 p 하(1)=8 kg/mm 상(2), upset 압 p 하(2)=20 kg/mm 상(2), 압접가열시간 t 하(1)=3초, upset 시간 2.5초를 선정한 것이 매우 타당함이 실험적으로 입증되었다. (2) 이종재질 SUH3-SUH31, SCr4-SUH31, SCr4-SUH3, SUH3-CRK22, SCr4-21-4N 및 SUH3-21-4N의 마찰압접에 관한 저자의 종래 연구와 본연구 결과는 압접부의 압접 특성이 서로 매우 일치하였다. (3) SCr4-21-4N 및 SUH3-21-4N의 마찰압접부의 잔류응력 및 전도의 peak를 제거하기 위한 최적열처리조건은 $600^{\circ}C$$\times$30min.$\times$room air cooling의 normalizing임이 확인되었다. (4) 이때 열처리 후에는, 열처리전의 인장강도의 약 20%가 감소했으나, 파단 위치는 열영향부로부터 모재 SCr4 및 SUH3 측으로 이동하였다. (5) 상기 최적조건 하에서 마찰압접되고 열처리된 압접부의 현미경 조직검사 결과, 압접부가 매우 좁고 압접결함이 없으며, 치밀하고 조밀한 조직의 우수한 압접이었음이 확인되었다. (6) 상기 최적조건은, 기관 valve 생산을 위한 타이종재질의 마찰압접조건으로도 응용될 수 있을 것이다.

  • PDF

수직관내(垂直管內)를 흘러내리는 액막식(液膜式) 흡수기(吸收器)의 흡수(吸收) 및 열전달특성(熱傳達特性)(제(第)2보(報) 열전달특성(熱傳達特性)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (2nd. Report, Characteristics of Heat Transfer))

  • 엄기찬;이동호;최국광;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.257-264
    • /
    • 1993
  • This is the second report of a three part study on the absorption and heat transfer characteristics of absorber, the correlation of refrigerating capacity and heating capacity. The 2nd report deals with the heat transfer characteristics of a vertical falling film type absorber of inner copper tube. The solute is LiBr-Water solution(60wt%) and the solvent is water vapor. The film Reynoles numbers are varied in the range of 35~130. The states of LiBr solution at the top of absorber are supercooled liquid and superheated liquid. The results are summarized as follows ; Heat transfer results reveal that for the absorption of falling film, the state of LiBr solution appears to be influential in determining the heat transfer. Thus, for the state of supercooled liquid, heat transfer coefficient decreases with increasing the film Reynolds number, but in the condition of superheated liquid, it increases conversely. The mass transfer coefficients that were presented in the 1st.report and heat transfer coefficients of this paper are presented as the dimensionless correlation. The optimum water flowrate which brings about maximum value of heat flux in the film exists, and that increases with increasing the cooling water temperature.

  • PDF

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

도시철도 승강장 스크린 도어의 풍압 안정성 해석 (The Wind Pressure Stability Analysis of the Platform Screen Door in Urban Railway)

  • 송문석;이승일
    • 한국철도학회논문집
    • /
    • 제15권1호
    • /
    • pp.17-22
    • /
    • 2012
  • 스크린 도어는 승강장에 설치하여 차량운행에 의한 승객의 안전을 확보하고, 승강장 내 공기질을 확보를 통한 쾌적함을 유지하며, 냉난방 에너지를 줄임으로써 다양한 효용성을 확보하고 있다. 이러한 스크린 도어의 안정성을 확보하기 위해서는 내풍압 평가를 고려한 설계가 필요하다. 본 연구에서는 승강장 스크린 도어의 내풍압을 예측하기 위하여 소사역사, 반밀폐형 스크린 도어, 전동차를 모델링하고 해석을 수행하였다. 또한 소사역은 지상역으로 외부에 노출되어 있기 때문에 기후조건에 영향을 받게 된다. 따라서 최악의 기후조건인 태풍의 영향을 고려하여 해석을 수행하였다. 해석결과, 최대 내풍압은 287 Pa이고, 외풍압을 고려한 최대압력은 865 Pa로 설계조건은 2756.25 Pa보다 약 3.1배 차이로 안정성이 확보됨을 알 수 있다.

R410A를 이용한 브레이징 타입 판형열교환기에서 물 측 유동방향에 따른 응축/증발 성능 평가 (An Experimental Study on Evaporation/Condensation Heat Transfer with Flow Direction in Brazed Plate Heat Exchanger using Refrigerant 410A)

  • 이성우;정영만;이재근;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1096-1101
    • /
    • 2009
  • The plate heat exchanger(PHE) in heat pump has two flow streams of the refrigerant and water. The flow direction of the refrigerant, unlike that of water, can be changed by a 4-way valve depending on operating condition. Therefore the flow arrangement is a parallel flow for heating and a counter flow for cooling, respectively. In this study, the effects of the flow direction of the water on the heat transfer rate are investigated experimentally. The experiments are carried out for brazed plate heat exchangers under a parallel and counter flow conditions in evaporation and condensation. The experimental parameters in this study include the mass flux of the refrigerant 410A from 3 to $14\;kg/m^2s$ and the flow patterns for the pressure of PHE fixed at 0.97 and 2.46 MPa. The results show that both the heat transfer rate and frictional pressure drop across the PHE increase with the mass flux. The heat transfer rate of the refrigerant 410A for evaporation show great sensitivity to flow direction of the water. The heat transfer rate for evaporation with a counter flow are 5-30% higher than that with a parallel flow.

  • PDF

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

잣나무열처리재의 흡방습성능에 미치는 영향인자 분석 (Analysis of Factors Affecting the Hygroscopic Performance of Thermally Treated Pinus koraiensis Wood)

  • 장윤성;한연중;엄창득;박주생;박문재;최인규;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권1호
    • /
    • pp.10-18
    • /
    • 2012
  • 최근 만들어지고 있는 거주공간은 단열성능 향상을 통한 냉난방 에너지 절약을 위하여 더욱 기밀해지고 있다. 이로 인해 일상생활 중에 발생하는 수분의 인위적인 배출과 외부공기의 인위적인 유입이 줄어듦에 따라 건축내장재의 자연조습기능에 대한 관심이 증대하고 있다. 본 연구에서는 열처리된 잣나무의 흡 방습성능을 평가하고 이에 영향을 미치는 인자들을 분석하였다. 상대습도 변화에 따른 평형함수율과 흡 방습률을 측정하였고, 조도(거칠기)와 미시적 표면형상, 그리고 FT-IR spectrum과 흡방습성과의 관계를 고찰하였다. 본 연구결과는 거주공간의 조습성능 정량화 평가시스템 구축을 위한 기초자료로 활용될 수 있을 것이라 기대된다.

통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향 (The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor)

  • 이춘석;류남형
    • 한국조경학회지
    • /
    • 제40권5호
    • /
    • pp.100-108
    • /
    • 2012
  • 통풍과 차양이 하절기 옥외공간에서 인간이 느끼는 온열쾌적성에 어떤 영향을 미치는지를 객관적으로 검증하기 위하여 통풍과 차양을 달리한 실험구를 조성하고 흑구온도와 기온 및 풍속을 측정하여 평균복사온도를 환산하여 비교 분석하였다. 미기후 측정을 위하여 개방된 잔디밭에 철제 각관을 이용하여 가로${\times}$세로${\times}$높이가 각각 $3m{\times}3m{\times}1.5m$인 프레임을 구성하고, 투명 폴리에틸렌 필름과 농업용 차광막을 이용하여 통풍과 차양의 조건을 달리한 네 가지의 실험구를 조성하였다. 각 실험구 내 중심부 지면으로부터 1.2m 높이에서 베인형 풍속계와 흑구, 측온저항체(PT-100)를 이용하여 2011년 5월 1일부터 동년 9월 30일까지 풍속과 기온, 흑구온도를 매 분 단위로 계측하였다. 기상조건과 계측자료의 유효성 등을 고려하여 총 44일 동안의 13,262건의 자료를 바탕으로 실험구별 일중 시계열적 변화를 분석하였으며, 낮 시간에 해당되는 오전 7시부터 오후 8시까지의 7,172건의 자료를 바탕으로 실험구에 따른 통계적 차이를 해석하였다. 아울러 햇볕이 가장 강렬한 시간대인 오전 11시부터 오후 4시까지의 자료를 바탕으로 평균복사온도와 풍속 및 일사량과의 관계를 분석하였다. 평균복사온도를 기준으로 해석했을 때, 통풍이 차단된 노지에서의 측정기간 중 최고값이 $58.84^{\circ}C$까지 상승한 반면, 차양이 적용되고 통풍이 원할한 실험구의 최고값은 $42.94^{\circ}C$였다. 시험결과를 종합하면, 하절기 옥외공간에서 낮 동안의 평균복사온도에 있어서 차양에 의해서는 최대 $13^{\circ}C$, 평균 $9^{\circ}C$의 냉각효과가 발생한 반면, 방풍에 의해서는 반대로 평균 약 $3^{\circ}C$의 가열효과가 있는 것으로 정리되어, 통풍이 되지 않는 태양직사광 지역은 바람이 원활하게 통하는 그림자 지역 보다 최대 $16^{\circ}C$까지 높은 것으로 나타났다. 결론적으로 본 연구를 통해서 하절기 옥외공간의 열쾌적성을 개선하는데 차양이 가장 중요하며, 그 다음이 통풍이라는 사실을 파악할 수 있었다. 따라서 옥외공간에 더 많은 녹음수와 숲을 조성하여 그림자 지역을 증가시킴으로써 인간의 하절기 옥외활동에 많은 제약을 주고 있는 불필요한 열에너지를 현격하게 저감시켜 쾌적한 미기후를 효과적으로 조성할 수 있으며, 나아가 정교하게 조성된 바람길이나 통풍 시스템을 적용한다면 도시 전체의 열환경도 효과적으로 개선할 수 있을 것이다.