• Title/Summary/Keyword: heater design

Search Result 340, Processing Time 0.028 seconds

A Theoretical and Experimental Study for the Design of Solar Air Heaters Using Porous Material (다공성 물질을 이용한 공기용 태양열 집열기의 설계를 위한 이론 및 실험적 연구)

  • Hwang, Yong-Ha;Park, Seung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.336-345
    • /
    • 1996
  • A theoretical and experimental study was conducted in order to design highly efficient solar air heaters using porous material. Radiative characteristics of glass windows and porous absorbing media were correlated through spectral transmittances measured by the UV-Visible and the FT-IR spectrometers. Using those characteristics the efficiencies of collectors were numerically calculated with the use of the two-flux radiation model. Based on the theoretical results, an experimental solar collector was designed and constructed. Experimental results under various conditions show that the daily efficiencies are over 60% in general and agree well with the theoretically calculated ones.

Design and Performance Evaluation of Extension-Type Actuators with a Displacement Amplification Mechanism Based on Chevron Beam

  • Jo, Yehrin;Lee, Euntaek;Kim, Yongdae
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a new design of an extension-type actuator (ExACT) is proposed based on a chevron structure with displacement amplification mechanisms by local heating. ExACT comprises diamond-shaped displacement amplification structures (DASs) containing axially oriented V-shaped chevron beams, a support bar that restricts lateral heat deformation, and a loading slot for thin-film heaters. On heating the thin film heater, the diamond-shaped DASs undergo thermal expansion. However, lateral expansion is restricted by the support bar, leading to displacement amplification in the axial direction. The performance parameters of ExACT such as temperature distribution and extended displacement is calculated using thermo-mechanical analysis methods with the finite element method (FEM) tool. Subsequently, the ExACTs are fabricated using a polymer-based 3D printer capable of reproducing complex structures, and the performance of ExACTs is evaluated under various temperature conditions. Finally, the performance evaluation results were compared with those of the FEM analysis.

Optimal design of a micro evaporator to maximize heat transfer coefficient (열전달 계수 최대화를 위한 마이크로 증발기의 최적 설계)

  • Sung, Tai-Jong;Oh, Dae-Sik;Seo, Tae-Won;Kim, Jong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2097-2101
    • /
    • 2007
  • This paper presents an optimal design of a micro evaporator which maximizes the heat transfer coefficient. Number of gaps, spanwise distance and streamwise distance are selected as the geometric design parameters. Mass flow rate of the refrigerant is selected as the non-geometric design parameter. Temperature at the surface of the heater is measured to valuate the heat transfer coefficient. Nine experiments are conducted using $L_9(3^4)$ orthogonal array. Maximum heat transfer coefficient is 640 W/$m^2K$ at the parameters of 2 gaps, 0.2 mm spanwise distance, 1.0 mm streamwise distance and 0.72 g/s mass flow rate. Among the 3 geometric parameters, the spanwise distance is the most sensitive parameter influencing the heat transfer coefficient. We conduct a second stage of experiment to increase the heat transfer coefficient by reselecting the mass flow rate. We concluded that 0.87 g/s is the optimized flow rate for an active micro cooler resulting in a heat transfer coefficient of 651 W/$m^2K$.

  • PDF

A Study on the User Required Unit Space in Elderly Housing -Special Reference to Yoodang Village (거주자 요구에 의한 유료 양로 시설의 단위 공간 계획 방향에 관한 연구-유당마을을 중심으로-)

  • 오혜경
    • Korean Institute of Interior Design Journal
    • /
    • no.3
    • /
    • pp.85-90
    • /
    • 1994
  • The purpose of this study was to present design direction of a unit plan in elderly housing. In order to perform the above purpose, this study was organized into two sections. First, literature review to understand the relationship between late adulthood development and housing environment, unit plan of elderly housing and design needs. Second, questionnaire and field survey research to seek a design direction of unit plan. Statistics were frequency, percentage, mean and crosstabulated analysis. The major findings were summerized as follows ; 1) The size of ideal single room was 20.4$m^2$-28.5$m^2$, and the minimum size for the couple was 28.5$m^2$. 2) The entrance of each room must not be faced each other, in case of the corridor type building like YooDang village. 3) Spare heater which can be turned on anytime was requested in bathroom especially for wintertime or whenever elderly need more heat. 4) The minimum size of closet was 1.5m per single room and the ideal size of it is over 1.8m. 5) The platform ondol type bed was ideal type bed was ideal for Korean elderly.

  • PDF

Optimal Design of High Temperature Vacuum Furnace Using Thermal Analysis Database (전산 열해석 DB를 이용한 초고온 진공로 최적설계)

  • Li Zhen-Zhe;Park Mee-Young;Byun Yung-Hwan;Lee Chang-Jin;Lee Jae-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.594-601
    • /
    • 2006
  • Optimization study has been carried out to design an energy efficient, high temperature vacuum furnace which satisfies users' design requirements. First of all, the transient temperature distribution and the uniform temperature zone results have been compared with the steady state results to validate the feasibility of using steady state solution when constructing the thermal analysis DB. In order to check the accuracy, the interpolated results using thermal analysis DB have been compared with the computational and the experimental results. In this study, total heat flux is selected as the objective function, and the geometry parameters of vacuum furnace including the thickness of insulator, the heat zone sizes and the interval between heater and insulator are the design variables. The Uniform temperature zone sizes and the wall temperature are imposed as the design constraints. With negligible computational cost a high temperature vacuum furnace which has $40\sim60%$ reduction in total heat flux is designed using thermal analysis DB.

An Experimental Study of Shell and Tube Heat Exchanger Performance with Baffle Spacing (배플수에 따른 원통다관형 열교환기 성능에 관한 실험 적 연구)

  • Lee, Yuk-Hyeong;Kim, Sun-Yeong;Park, Myeong-Gwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1748-1755
    • /
    • 2001
  • The shell and tube heat exchangers were introduced to apply to a big capacity condenser and a high pressure feed water heater for power plant in the beginning of 1990s. Design and manufacturing technology fur shell and tube heat exchangers have been developed until now. But it is very difficult to calculate the expected performance characteristics of the shell and tube heat exchanger, because there are many design parameters to be considered according to internal structure and the shell side heat transfer mechanism complicately related to the design parameters. Design parameters to be considered in the design stage of shell and tube heat exchanger are shell and tube side fluids, flow rate, inlet and outlet temperature, physical properties, type of heat exchanger, outer diameter, thickness, length of tube, tube arrangement, tube pitch, permissive pressure loss on both sides, type of baffle plate, baffle cutting ratio. The propose of study is an analysis TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with changing a number of baffles(3, 5, 7, 9, 11) and tubes(16, 20) and determined optimal baffle spacing.

Sensitivity Analysis of Contact Resistance for Thermal Analysis of Spacecraft (위성 열해석을 위한 접촉열저항의 민감도 해석)

  • Han, Cho-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.117-125
    • /
    • 2004
  • Performing the sensitivity analysis of contact conduction on the basis of the thermal model already established, the study of thermal design is accomplished for the preparation of the future changes of mechanical interface design. A relatively simple thermal model is taken into consideration for the convenience of the analysis. A variety of the spacecraft bus voltages and the contact resistances are tried. As a consequence, when the mechanical interface condition is changed at the same module, the successful thermal design could be achieved if we design the heater to have sufficiently large power with reference to the heritage of contact resistance.

Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber (반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선)

  • Lee, Kwang-Ju;Jeong, Kyung-Seok;Park, Sung-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3626-3632
    • /
    • 2010
  • Some design changes were made to enhance the uniformity of temperature distribution inside the chamber of semiconductor test equipment. The design changes include the installation of adjustable airflow controller inside the chamber, the alignment of the centers of heater and match plate, the change in the size and the shape of holes in match plate base, and the addition of new holes of 2 mm diameter in order to allow airflow directly to the temperature sensors. In order to verify their effects, the temperature distributions inside the chambers were measured using 32 RTD sensors before and after the design changes. The temperature distributions were in the ranges of 87.1 to $91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$) and 89.5 to $90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$) before and after the design changes, respectively. The above temperature distribution after design changes was maintained for longer than 15 minutes, which satisfied the target temperature range of $90{\pm}1^{\circ}C$ for longer than 10 minutes.

Thermo-mechanical Design for On-orbit Verification of MEMS based Solid Propellant Thruster Array through STEP Cube Lab Mission

  • Oh, Hyun-Ung;Ha, Heon-Woo;Kim, Taegyu;Lee, Jong-Kwang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.526-534
    • /
    • 2016
  • A MEMS solid propellant thruster array shall be operated within an allowable range of operating temperatures to avoid ignition failure by incomplete combustion due to a time delay in ignition. The structural safety of the MEMS thruster array under severe on-orbit thermal conditions can also be guaranteed by a suitable thermal control. In this study, we propose a thermal control strategy to perform on-orbit verification of a MEMS thruster module, which is expected to be the primary payload of the STEP Cube Lab mission. The strategy involves, the use of micro-igniters as heaters and temperature sensors for active thermal control because an additional heater cannot be implemented in the current design. In addition, we made efforts to reduce the launch loads transmitted to the MEMS thruster module at the system level structural design. The effectiveness of the proposed thermo-mechanical design strategy has been demonstrated by numerical analysis.

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • v.10 no.4
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.