• Title/Summary/Keyword: heater

Search Result 1,744, Processing Time 0.022 seconds

Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine (가스엔진용 유기랭킨사이클의 설계 및 제작)

  • Lee, Minseog;Baek, Seungdong;Sung, Taehong;Kim, Hyun Dong;Chae, Jung Min;Cho, Young Ah;Kim, Hyoungtae;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.65-72
    • /
    • 2016
  • ORC system was designed and constructed for utilizing the heat of the exhaust gas and coolant released from the gas engine which was modified to use natural gas as a fuel. In this paper the components of the ORC system were designed and manufactured based on measured data of the gas engine. The components are composed of two plate heat exchanger, the 5kW-class expander and multi stage centrifugal pump. The thermodynamic performance of the ORC system was analyzed by using the electric heater. Also, the developed ORC system was implemented to modified natural gas engine. Two gas engines were used to supply heat to the ORC system. As a result of test bench, when the heat source temperature is $110^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 5.22kW, 7.41, 9.09%. As a result of field test, when the heat source temperature is $86^{\circ}C$ expander shaft power, the pressure ratio and cycle efficiency is 2kW, 3.75, 6.45%.

Analysis of Temperature Distributions in Spray Coating Room (스프레이 코팅 룸의 온도분포 해석)

  • Kim, Nam Woong;Kim, Sung-Yong;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7667-7671
    • /
    • 2015
  • Recently, Zinc coating is often used with environment friendly features and high performance. Generally The coating temperature is one of main factors for determining coating thickness and coating ability, so the optimal coating temperature is strongly required. In this paper, the thermo-flow simulation considering the air flow inside the coating rooms for analyzing the temperature distributions of Zinc spray coating room was performed. Two spray coating rooms, preheating room and drying room were all modeled by SolidWorks program and the temperature distributions were analyzed by Flow simulation program. The analysis results were verified with the measured data by thermal image camera. The characteristics of temperature distributions of the first spray room and the second spray room were understood and the results showed that the temperatures of two spray coating room were low compared with the target temperature $25^{\circ}C$. To the exclusion of heater addition, the simulation with all the same conditions exclusive the exhaust fan was performed, which showed that the temperatures of the first and the second spray rooms increased by $6.2^{\circ}C$ and $5.8^{\circ}C$. This analysis can be applicable for designing a new spray coating room for improving performance.

Development of simulation method for heating line optimization of E-Mold by using commercial CAE softwares (전산모사 프로그램을 이용한 E-MOLD의 Heating Line 배치의 최적화 설계에 관한 연구)

  • Chung, Jae-Youp;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1754-1759
    • /
    • 2008
  • To produce plastic parts that have fine pattern through conventional injection molding, a lot of difficulties follow. Therefore, rapid heating and cooling methods are good candidates for manufacturing injection-molded parts with micro/nano patterns. In this study, we adopted the E-Mold patent technology. The mold for E-Mold technology has a separate heated core with micro heaters. It is very important to optimize the lay-out of the heaters in heated core because it influences both control and distribution of mold temperature. We developed a optimization method of heating line lay-out by using commercial softwares and compared the output with the experimental results. We used Pro-Engineer Wildfire 2.0 for the mold design, ICEMCFD for mesh generation, and FLUENT for heat transfer simulation. The simulation results showed the temperature profile from $60^{\circ}C$ to $120^{\circ}C$ or $180^{\circ}C$ during heating and cooling process which were compared with the injection molding experiments. We concluded that the simulation could well explain the experimental results. It was shown that the E-Mold optimization design for heater lay-out could be available through the simulation.

Mechanism improvement of the heat exchanger and the ventilator for the thermal efficiency increment of hot-air heater (온풍난방기의 열이용효율 증대를 위한 열교환부 및 송풍기 구조개선)

  • 이기명;박규식;최성우
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.558-563
    • /
    • 2002
  • 시설원예에서 난방장치를 사용하는 겨울철 재배 농산물의 생산비 중 난방 연료비가 30%~37% 정도를 차지하여 비중이 가장 높다. 따라서 시설원예 농가에서는 난방비를 절감하는 것이 농가소득과 직결되므로, 난방장치의 선정이 대단히 중요하다. 본 연구에서는 겨울철 재배 농산물의 생산비 중 30%-37% 정도를 차지하는 연료비를 절감하기 위해 기존의 온풍난방기와 다른 새로운 방식의 열교환기와 원심식 송풍블로워를 사용하는 블로워 송풍방식의 온풍난방기를 개발하고 개발된 온풍난방기의 가동으로 인한 난방 연료비 절감효과와 온실내의 균일한 온도분포를 획득하기 위해 8연동 비닐온실에서의 시험을 실시하였으며 얻어진 결과를 요약하면 다음과 같다. 가. 저 정압용의 전동기 축직결식 송풍팬을 대신하여 고 정압용의 블로워 송풍팬을 장착하고 열교환 면적을 크게 한 지그재그식 환류의 열교환실을 채용한 온풍난방기를 개발하였다. 나. 공시한 온실에서 기존 온풍난방기의 2일 가동시 DH당 연료 사용량이 평균 1.082$\ell$/$^{\circ}C$.hr 이며, 블로워 송풍방식 온풍난방기의 3일 가동시 DH당 연료 사용량은 평균 0.854$\ell$/$^{\circ}C$.hr로써 21%의 난방 연료비 절감효과가 나타났다. 다. 블로워 송풍방식 온풍난방기는 동일시간대 3$^{\circ}C$의 경시적 온도변화가 발생하였고, 기존의 은풍난방기의 동일시간대 온도변화는 최대 6.1$^{\circ}C$로 나타나 개발된 블로워 송풍방식 온풍난방기가 동일시간대 온실내의 온도변화를 크게 줄일 수 있었고 온도분포를 비교적 균일하게 하는 효과가 있음을 확인하였다.도 33$^{\circ}C$를 기준으로 한 열 회수 시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$ 일 각각 120분 및 140분으로 나타났다. (3) 제 3종 자갈: 축열조로 공급되는 공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때, 축열조 출구의 공기온도가 33$^{\circ}C$에 도달될 때까지 가열되는데 소요된 시간은 가열공기의 온도가 52$^{\circ}C$와 64$^{\circ}C$ 일 때 각각 180분과 150분이었고, 방열에 소요된 시간은 각각 240분 및 270분으로 나타났다. 방열과정 동안 축열조 출구의 최고 공기온도는 가열 공급공기의 온도가 52$^{\circ}C$$65^{\circ}C$일 때 각각 35.5$^{\circ}C$ 및 39.5$^{\circ}C$였다. 출구 공기온도 33$^{\circ}C$이상을 기준으로 한 에너지 회수시간은 유입공기 온도가 52$^{\circ}C$ 및 64$^{\circ}C$일 때 각각 140분 및 160분으로 나타났다. 이와 같이 자갈이 작을수록 축열조 출구의 공기온도가 기준온도 33$^{\circ}C$에 도달되는 시간이 길었으며, 이것은 축열조내의 공극이 작고 비중량이 커 자갈층을 가열시키는 축열시간이 길어지기 때문인 것으로 사료된다. 또한 작은 자갈일수록 방열시간도 다소 길어져 회수 가능 열에너지가 큰 것으로 나타났다

  • PDF

A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection (강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Hwang, In-Phil;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.189-199
    • /
    • 2010
  • In a high-level waste (HLW) repository, heat is generated by the radioactive decay of the waste. This can affect the safety of the repository because the surrounding environment can be changed by the heat transfer through the rock. Thus, it is important to determine the heat transfer coefficient of the atmosphere in the underground repository. In this study, the heat transfer coefficient was estimated by measuring the indoor environmental factors in the Korea Atomic Energy Research Institute Underground Research Tunnel (KURT) under forced convection. For the experiment, a heater of 5 kw capacity, 2 meters long, was inserted through the tunnel wall in the heating section of KURT in order to heat up the inside of the rock to $90^{\circ}C$, and fresh air was provided by an air supply fan connected to the outside of the tunnel. The results showed that the average air velocity in the heating section after the provision of the air from outside of the tunnel was 0.81 m/s with the Reynolds number of 310,000~340,000. The seasonal heat transfer coefficient in the heating section under forced convection was $7.68\;W/m^2{\cdot}K$ in the summer and $7.24\;W/m^2{\cdot}K$ in the winter.

Development of Induction Brazing System for Sealing Instrumentation Feedthrough Part of Nuclear Fuel Test Rig (핵연료조사리그 계장선 통과부위의 밀봉을 위한 유도 브레이징 시스템 개발)

  • Hong, Jintae;Kim, Ka-Hye;Heo, Sung-Ho;Ahn, Sung-Ho;Joung, Chang-Young;Son, Kwang-Jae;Jung, Yang-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1573-1579
    • /
    • 2013
  • To test the performance of nuclear fuels, coolant needs to be circulated through the test rig installed in the test loop. Because the pressure and temperature of the coolant is 15.5 MPa and $300^{\circ}C$ respectively, coolant sealing is one of the most important processes in fabricating a nuclear fuel test rig. In particular, 15 instrumentation cables installed in a test rig pass through the pressure boundary, and brazing is generally applied as a sealing method. In this study, an induction brazing system has been developed using a high frequency induction heater including a vacuum chamber. For application in the nuclear field, BNi2 should be used as a paste, and optimal process variables for Ni brazing have been found by several case studies. The performance and soundness of the brazed components has been verified by a tensile test, cross section test, and sealing performance test.

Magnetic Susceptibility depending on the Thermal Degradation of HK-40 Steel (HK-40강의 열화도에 따른 자화율의 변화)

  • Kim, Jeong-Min;Son, De-Rac;Park, Jong-Seo;Nahm, Seung-Hoon;Kim, Dong-Gyun;Han, Sang-In;Choi, Song-Chun;Ryu, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2004
  • Since the used materials of furnace heater tube with different kinds of thermal degradation were not commonly available, the HK-40 steel specimens were heat-treated isothermally at elevated temperature to simulate the microstructure at the service temperature. HK-40 steel specimens with five different aging time were prepared by isothermal heat treatment at $1050^{\circ}C$. The characteristics of the magnetic susceptibility have been investigated for the degradation evaluation of HK-40 steel. The magnetic susceptibility at room temperature increases as the extent of degradation of the materials increases. The variation of magnetic susceptibility was compared with the variation of tensile properties and Vickers hardness. To investigate the effect of the microsturctural change on the characteristics of tensile properties, hardness and magnetic susceptibility, the microstructures were examined by a scanning electron microscope(SEM) and the chemical compositions were analyzed by a energy spectrometer of SEM. As a result, the magnetic susceptibility method can be suggested as one of the nondestructive evaluation methods for the degradation of the HK-40 steel.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Research and development on image luminance meter of road tunnel internal and external (도로터널 내/외부의 영상휘도 측정기 연구개발)

  • Jang, Soon-Chul;Park, Sung-Lim;Ko, Seok-Yong;Lee, Mi-Ae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • This paper introduces the development of imaging luminance meter which measures the luminances of external/internal road tunnel. The developed imaging luminance meter complies with both L20 method and Veiling luminance method of the international standards, CIE88. In this paper the L20 method is mainly presented because most of tunnels currently adapt L20 method. The developed system has an embedded computer to operate at stand-alone. The system has a ethernet port, a heater, a fan, a defroster, a wiper and sun shielder. Compensation algorithm is applied for correcting non-linear responses to the luminance and integration time. The accuracy of measurement is less than 1% when it calibrated at the public certification institute. The developed system was also tested at the real field, road tunnel. The test results were very similar with the reference luminance meter and showed that the developed system operates well at the real field. Partial sensor saturations were happened to show the less luminance, because there were the high reflecting objects in the real field. Further study should be followed for high luminance measurement.

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.