• 제목/요약/키워드: heater

검색결과 1,744건 처리시간 0.026초

분리형 전기순간가열기에 의한 온수 비데 설계 (Design of Hot-water wit an Electric Instantaneous Water Heating Unit)

  • 고석조;김창동
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2004
  • There are an electronic and a manual type in Bidet. The electronic bidet has some advantages. it supplies multiple functions and is up easily. However, it has frequent defects and a high price. The manual bidet is not need to supply electric and is cheaper than the electronic type. However, it is needed to supply hot water and is hard to set up. In order to solve these defects, this study designed a bidet heating unit using an electric instantaneous water heating method. To get a proper heating elements, experiments were performed about a Ni-Cr heater and a film heater.

  • PDF

실리콘 튜브의 변경으로 인한 절전형 비데용 순간 히터 온도 절감 효과 (A Effect Saving Temperature of Instantaneous Heater Using An Economical Bidet Due to Change Silicon-Tube)

  • 정인룡;김원종;남상육;이춘성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2057-2058
    • /
    • 2011
  • We have studied that a effect saving temperature of instantaneous heater using an economical bidet due to change Silicon-Tube. The results, we have found that the existing instantaneous heater is reduced 15 [%], 20 [%] better than a new product instantaneous heater as a discharge water [${\ell}$/min] with temperature and ${\nabla}$ value, respectively. Therefore, we have showed that the innovative effect of a working process and the cost reduction because an economical bidet due to change Silicon-Tube.

  • PDF

조수기용 증기분사 열교환기에 대한 모델링 (Modeling of Steam Injection Heater for Fresh Water Generator)

  • 홍철현;이억수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.877-885
    • /
    • 2008
  • Steam injection heater is the most widely used method for fresh water generator throughout industry. This method is often chosen because of its simplicity. The steam bubbles condense and give up their heat to the surrounding liquid. Experimental study on steam injection heater has been performed in order to find the effect of major parameter. And conservation equation and Bernoulli obstruction theory are used for numerical simulation model of vapor flow-rate. Qualitative comparisons between simulations and measurements show a good agreement and the simulation models are thereby verified.

강재의 유도가열 방법의 수치적 승온 해석 (A Numerical Study on Temperature Profiles of Steel Plates Heated by Induction Heater)

  • 김형진;정원철;조병수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1412-1416
    • /
    • 2003
  • Induction Heaters are commonly used in heating steel strip product, because it can rapidly and efficiently heat steel strip/bar. In this study, a inductive heating model is developed and the predictions are compared with measured temperatures. The temperatures are measured from POSCO thin-slab rolling facility (so called Minimill). Induction heater is installed between reduction unit and holding furnace This induction heater raise the temperature of steel bars from $930^{\circ}C$ to about $1100^{\circ}C$ which gives the required temperature for finishing mill process after holding period at holding furnace. Unlike other simple equation models, this model allows us to predict temperature profiles of sections of steel bars.

  • PDF

냉각수 보급이 가정용 흡수식 냉난방기의 성능에 미치는 영향 (Effect on Household Absorption Chiller by the Supply of the Cooling Water)

  • 이호생;김동휘;최병권;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.267-272
    • /
    • 2002
  • The electric heat pump requiring HCFCs as a refrigerant has been for most residential air-conditioners in Korea. They cause a surge up electric power demand during summer. Moreover, the use of HCFCs and HFCs causes a serious problem to the global environment such as global warming and ozone layer destruction. An absorption chiller and heater could solve such problems. It was built and tested for analyzing the performance of the absorption chiller/heater. Experiment was done with a 1.5RT household absorption chiller and heater. It was experimented that the cooling capacity, gas capacity, COP were researched by the temperature of cooling water. The change of the cooling water temperature have effect the temperature(or pressure) of the parts on absorption chiller The result of the change of the cooling water temperature have the effects of the absorption chillers. This data will help to operate the household absorption chiller and heater.

  • PDF

고압형 급수가열기 동체 감육 완화를 위한 추기노즐 주변의 유동특성 연구 (A Study on the Flow Characteristic of surroundings of the Extracting Nozzle for Shell Wall Thinning of a Feedwater Heater)

  • 서혁기;김윤신;김경훈;황경모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.841-846
    • /
    • 2009
  • Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied several impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

  • PDF

이종의 인두기 히터를 제어하는 솔더링 스테이션 (A soldering station controller for two types heater)

  • 오갑석
    • 동력기계공학회지
    • /
    • 제19권3호
    • /
    • pp.48-54
    • /
    • 2015
  • This paper introduced a design method of soldering station that can control two types of soldering iron heater. At design time, to distinguish two types of soldering iron heater the voltage divider rule has been applied, and the distinguished resistor is inserted to handler of soldering iron to prevent misuse by users. And an algorithm to design a PID controllers is proposed. The proposed controllers parameter which can be easily realized, and are designed by using the input output data from systems, and have outstanding ability making the output response of nonlinear systems similar to the desired one. Temperature control experiments were performed to verify the ability of the suggested controller. As a result, suggested PID controller followed the desired ones, and one soldering station can control the various type of soldering irons in real time.

Sn-3.5Ag 솔더를 이용한 페리퍼럴 어레이 플립칩의 열 성능 분석

  • 이택영
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2003년도 기술심포지움 논문집
    • /
    • pp.270-277
    • /
    • 2003
  • Thermal performance of flip chip bonding with Sn-3.5Ag solder ball was studied. The temperature distribution was measured with IR(InfraRed) camera of 25 urn resolution. The measurement shows that most of the samples had much higher maximum temperature than average temperature. With central heater and 2.5 (W), the difference between maximum and average temperature is over $80^{\circ}C$. The distribution was influenced by the location of heater, the distance from heater to flip chip bonding, and the passivation opening of solder bumps. To reduce the maximum temperature, the bigger passivation opening, the smaller chip size, and the closer location of heater to flip chip bumps are preferrable.

  • PDF

Fatigue Test of MEMS Device: a Monolithic Inkjet Print

  • Park, Jun-Hyub;Oh, Yong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.798-807
    • /
    • 2004
  • A testing system was developed to improve the reliability of printhead and several printheads were tested. We developed a thermally driven monolithic inkjet printhead comprising dome-shaped ink chambers, thin film nozzle guides, and omega-shaped heaters integrated on the top surface of each chamber. To perform a fatigue test of an inkjet printhead, the testing system automatically detects a heating failure using a Wheatstone bridge circuit. Various models were designed and tested to develop a more reliable printhead. Two design parameters of the width of reinforcing layer and heater were investigated in the test. Specially., the reinforcing layer was introduced to improve the fatigue life of printhead. The life-span of heater with a reinforcing layer was longer than that without a reinforcing layer. The wider the heater was, the longer the life of printhead was.

마이크로 가스센서의 열적 성능에 관한 연구 (A Study of Thermal Performances for Micro Gas Sensor)

  • 주영철;김창교
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.531-537
    • /
    • 2006
  • A lever type $NO_2$ micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro heater was built on the gas sensor. The sensing material laid on the heater and electrodes and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor to a target temperature was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power of micro heater to heat up the sensing material to the target temperature showed a good agreement with the measured data. The design of micro gas sensor could be modified to show more uniform temperature distribution and to consume less electric power by optimizing the layout of micro heater and electrodes.