• Title/Summary/Keyword: heat-damage

Search Result 981, Processing Time 0.026 seconds

Analysis of Illegally Mixed Used Lube Oil in Bunker C (폐윤활유 불법혼입 C중유 물성 분석)

  • Lim, Young-Kwan;Lee, Jae-Min;Kim, Wan-Sik;Lee, Jeong-Min
    • Tribology and Lubricants
    • /
    • v.34 no.5
    • /
    • pp.191-196
    • /
    • 2018
  • Bunker C is used in heavy-lift ships, furnaces, and boilers for generating heat, and power. Bunker C has only four regulations for quality standards and is rarely inspected in Korea. For these reasons, other oils such as used lubricant oil are commonly blended with Bunker C. This illegal mixture of fuel can damage the boilers, engines and affect the environment adversely. In this study, we investigate the fuel properties and perform atomic analysis of illegal Bunker C blended with used lube oil. The test results show that higher quantities of used lube oil in Bunker C have higher flash points, total acid numbers, copper corruption, solid contamination, and metal components. Further, increasing quantities of used lube oil in Bunker C cause lower viscosity, sulfur, and V content. However, adequate sample (approximately 1 L) is needed to evaluate presence of adulterants in Bunker C, we attempted the SIMDIST analysis. In the SIMDIST chromatogram, the used engine oils are detected for longer retention times than Bunker C owing to the high boiling point. We also quantitatively analyzed the lube oil content using SIMDIST.

Local dynamic buckling of FPSO steel catenary riser by coupled time-domain simulations

  • Eom, T.S.;Kim, M.H.;Bae, Y.H.;Cifuentes, C.
    • Ocean Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.215-241
    • /
    • 2014
  • Steel catenary riser (SCR) is a popular/economical solution for the oil/gas production in deep and ultra-deep water. The behavioral characteristics of SCR have a high correlation with the motion of floating production facility at its survival and operational environments. When large motions of surface floaters occur, such as FPSO in 100-yr storm case, they can cause unacceptable negative tension on SCR near TDZ (touch down zone) and the corresponding elastic deflection can be large due to local dynamic buckling. The generation, propagation, and decay of the elastic wave are also affected by SCR and seabed soil interaction effects. The temporary local dynamic buckling vanishes with the recovery of tension on SCR with the upheaval motion of surface floater. Unlike larger-scale, an-order-of-magnitude longer period global buckling driven by heat and pressure variations in subsea pipelines, the sub-critical local dynamic buckling of SCR is motion-driven and short cycled, which, however, can lead to permanent structural damage when the resulting stress is greatly amplified beyond the elastic limit. The phenomenon is extensively investigated in this paper by using the vessel-mooring-riser coupled dynamic analysis program. It is found that the moment of large downward heave motion at the farthest-horizontal-offset position is the most dangerous for the local dynamic buckling.

Evaluation of High Cycle Thermal Fatigue on Mixing Tee in Nuclear Power Plant (원전 Mixing Tee에서의 고주기 열피로 평가)

  • Lee, Sun Ki
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.22-29
    • /
    • 2020
  • In nuclear power plants, there is a risk of thermal fatigue in equipment and piping affecting system soundness because the temperature change of the system accompanies in every operation and shutdown. Therefore, in order to prevent the excess of the fatigue limit during the lifetime of plants, the fatigue limit of each piping material is determined in the designing stage. However, there are many cases where equipment or piping is locally subjected to thermal fatigue that is not considered in the design, resulting in damage to the equipment and piping, and failure during operation. Currently, local thermal fatigue generation mechanisms that are not taken into account in the design stage are gradually being identified. In this paper, the effects of the fluid temperature fluctuations on the piping soundness due to the mixing of hot and cold water, one of the local thermal fatigue generating mechanisms, were evaluated.

A Study on the Fire Risk Assessment of Combustible Exhaust Duct-fume (가연성 배기덕트-흄 화재위험성 평가에 관한 연구)

  • Yoon, Yeo-Song;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.32-37
    • /
    • 2010
  • When back-out & firing Process applies heat, hume is piled up in exhaust duct by organic compound and it have high dangerousness. There by, the process is happening a lot of damage that is exhaust duct fire. However we do not have certain fire dangerousness estimation and digestion countermeasure. So we need preventive measure. Back-out & firing is a process which has fine structure, electrical and mechanical characteristics, such as firing kiln and back-out kiln which has pipe line and box type. The box oven is made of heating coil, fan motor and control panel. Back-out & firing process has air circulation institution of quick ventilation type. When we operate this process for long time, fire can break out easily. Duct is made by zinc shredder. If fire breaks out in duct inside, fire by deposit fume can be dispersed easily. Accordinglym, This project estimate danger for back-out & firing process exhaust duct through real fire test. And there is purpose of study to establish preventive measure.

Characteristics of Photosynthetic Electron Transport Activity in Isolated Chloroplast of Korean Ginseng and Radish (인삼과 무 엽록체의 광합성 전자전달 활성)

  • 김갑식
    • Journal of Plant Biology
    • /
    • v.33 no.2
    • /
    • pp.111-118
    • /
    • 1990
  • In order to characterize the chloroplasts of Korean ginseng as a semi-shade plant and radish as a sun plant, effects of growth light intensity on photosynthetic electron transport (PS) activity in chloroplasts and superoxide (O2.-) production in thylakoid membrane by irradiation were investigated. High-light chloroplasts of both plants showed higher PS activities than those grown under ow growth light intensity. High PS II and low PS I activities in ginseng chloroplasts (ratio of PS II/PS I : 1.1) were observed, but radish chloroplasts showed low PS II and high PS I activities (ratio of PS II/PS I : 0.3). PS II activity of both plants was little affected by temperature in range of 15-35$^{\circ}C$. Activities of whole -chain (PS II+I) in ginseng and PS I in radish were increased at high temperature (4$0^{\circ}C$). Preincubation of chloroplasts at 4$0^{\circ}C$ during 30 min, as a mild heat stress, caused rapid decrease in PS II and PS II+I activities of both plants. However PS I activity was not decreased in ginseng and rather increased in radish. O2.- production (NBT reduction) in Mehler reaction in the thylakoid membrane was inhibited by DCMU in both plants. DMBIB inhibited O2.- production in ginseng, but radish was insensitive to DMBIB. Electron flow system in ginseng thylakoid membrane was more susceptible to damage of photooxidation than that of radish.

  • PDF

The Optimum Design According to Type Analysis of the Safety Circuit Design (LED 조명의 안전회로설계 Type분석에 따른 최적설계)

  • Jang, In-Hyeok;Kim, Jeong-Ho;Lim, Hong-Woo;Oh, Geun-Tae;Choi, Youn-Ok
    • Journal of Applied Reliability
    • /
    • v.16 no.4
    • /
    • pp.331-337
    • /
    • 2016
  • Purpose: The purpose of this study is the analysis of the failure mechanisms effect of circuit design characteristics of the ballast for LED Lamp Methods: Recently, electronic circuit of ballasts for LED lamp are being occurred on various failure mechanisms (whiskers, ion migration, heat dissipation problem, switching element damage) because electronic ballast circuit design characteristics are becoming more and more diverse. Results: we analysis failure mechanisms that occurs in accordance with the circuit design characteristics The ballast for LED lamp were divided into three different types (Type A, Type B, Type C) considering circuit design characteristics (thermal design, PCB patten spacing, element material) and it was experimented in the acceleration test conditions ($85^{\circ}C$, 85% R.H). Conclusion: We confirmed that failure mechanism of the ballast for LED Lamp had occurred differently in accordance with the circuit design characteristics.

Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber (미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석)

  • Sumon, S.M.;Lee, S.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

A study on the formability in warm hydroforming of Al 6061 seamless tube (온간액압성형공정에서 Al 6061 튜브의 소성변형특성에 관한 연구)

  • Yi, H.K.;Lee, Y.K.;Lee, J.H.;Sohn, S.M.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.318-321
    • /
    • 2006
  • In this strudy, the free-bulge test and FE analysis have been used to define the fracture criteria based on the cockroft and Latham's criterion in warm hydroforming of Al 6061 tube. Full annealing and T6 treatment for heat treatment of Al 6061 tube ware used in this study. As-extruded, full annealed and T6-treated Al 6061 seamless tubes were prepared. To evaluate the hydroformability, uni-axial tensile test and bulge test were performed between room temperature and $200^{\circ}C$. And measured flow stress was used to simulate the warm hydroforming. A commercial FEM code, DEFORM-$2D^{TM}$, was used to calculate the damage value. A forming limit based ductile fracture criteria has been proposed by the results of experimental and FE analysis. The calculated values for fracture criteria will be efficient to predict the forming limit in hydroforming for real complex shaped part.

  • PDF

A Study on the Fire-Safety Design for the Historic Buildings (역사적 건조물의 화재안전을 위한 기초연구)

  • Lee Ji-Hee
    • Journal of the Korean housing association
    • /
    • v.15 no.6
    • /
    • pp.107-113
    • /
    • 2004
  • Fire was and remains a great threat to historic buildings of wood. This threat is omnipresent and often results to irreparable property losses especially cultural heritages. Fire of historic buildings continues to increase every year. The purpose of this study is to preserve a life safety, historical heritage and architectural & cultural values by pursuing for fire safety in the historical buildings. This study shall employ two research methods: a literature review and field survey methods. The literature review shall focus on the observations of characteristics noted in fire codes. The field survey shall cover a heat analysis and fire protection equipment. A method is proposed to investigate fire codes related historical building, reported fire history Fire Codes and Regulations for modern buildings are not always applicable on the historic buildings. Old buildings, and some new buildings with architectural, historical or cultural importance may have values which cannot be measured on a monetary scale. Their protection against the damage caused by fire is considered to be one of the basic moral duties of society. It is strongly recommended, therefore, legislation for fire safety in historical buildings must be extended to a complementary relationship with 'active' fire protection measures, to provide safety in real historical building in real fire situations. The development and application of performance based Codes and the Fire Safety Engineering approach seems to be a rather reasonable and effective way to deal with this historical buildings.

Creep Damage Evaluation of High Temperature Material Using Small Punch Test Method (소형펀치실험법을 이용한 고온재료의 크리프 손상 평가)

  • Yu, Hyo-Sun;Lee, Song-In;Baek, Seung-Se;Na, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.265-268
    • /
    • 2000
  • In this study, a small punch creep (SP-Creep) test using miniaturized specimen has been described for the development of the new creep test method for high temperature structural components such as headers and tubes of boiler, turbine casing and rotor, and reactor vessel. The SP-Creep testing technique has been applied to 1Cr-0.5Mo steel used widely as boiler header material and the creep test temperature are varied at $550^{\circ}C{\sim}600^{\circ}C$. From the experimental results, e.g. SP-Creep curve behaviors, the creep rate in steady state and creep rupture life with test temperature and load, the load exponential value(n, m), the activation energy($Q_{spc}$), the Monkman-Grant relation and the creep life assessment equation etc., it can be summarized that the SP-Creep test may be a useful test method to evaluate the creep properties of the heat resisting material such as boiler header.

  • PDF