• Title/Summary/Keyword: heat-cold test

Search Result 292, Processing Time 0.027 seconds

Effect of the Coating Structure on the Corrosion Resistance of Al-Mg Coated Steel (Al-Mg 코팅층의 구조가 강판 내식성에 미치는 영향)

  • Jung, Jae-Hun;Yang, Ji-Hoon;Kim, Sung-Hwan;Byeon, In-Seop;Jeong, Jae-In;Lee, Myeong-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.5
    • /
    • pp.454-460
    • /
    • 2016
  • Double-layered Al-Mg films have been deposited by using an e-beam deposition method on a cold-rolled steel sheet(CR), which the structure of the film was Al/Mg/CR. The micro-structure, alloy phase, and corrosion resistance of the Al-Mg coated CR were investigated before and after heat treatment at $400^{\circ}C$ for 2, 3, and 10 min in a nitrogen atmosphere. Total thickness of Al-Mg films was fixed at $3{\mu}m$ and the thickness ratio of Al and Mg layers(Al:Mg) has been changed from 5:1 to 1:5. The cross-sectional morphology of the films, which had the thickness ratio of 2:1(Al:Mg), 1:1, and 1:2, was changed after heat treatment from columnar to featureless structure. The x-ray diffraction data for as-deposited films showed only pure Al and Mg peaks. Al-Mg alloy peaks such as $Al_3Mg_2$ and $Al_{12}Mg_{17}$ phase appeared after the heat treatment. The Al-Mg coating with the thickness ratio of 1:1(Al:Mg) showed the best corrosion resistance of up to 500 hours by salt spray test.

Flame characteristics of direct fired burner in fuel-air mixing conditions (열처리로 직화버너에서 연료-공기 혼합에 따른 화염 영향)

  • Lee, Cheolwoo;Kim, Youngho;Kim, Insu;Hong, Junggoo
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.285-288
    • /
    • 2014
  • Experiments have been performed for the burners used in the non-oxidizing direct fired furnaces for the cold rolled plate to investigate the effect of fuel/air mixing patterns of the burner nozzle on flame shape, temperature and combustion gas concentration. CFD simulation has also been performed to investigate the mixing state of air-fuel for a nozzle mixing burner and a partially pre-mixing burner. A partially pre-mixing burner showed that flame temperature increased up to $26^{\circ}C$ on average compared than that of the nozzle mixing. It also showed that the mixing distance is important at the partially pre-mixing burner. Test results for a partially pre-mixing burner showed that the residual oxygen concentration and the volume ratio of $CO/CO_2$ of the flame were applicable to be used in field furnaces.

  • PDF

Evaluation of Transient Natural Circulation Behavior during Accident in Low Power /Shutdown Condition of YGN Units 3/4

  • Bang, Young-Seok;Kim, Kap;Seul, Kwang-Won;Kim, Hho-Jung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.458-463
    • /
    • 1997
  • A transient natural circulation behavior during a LOCA at hot-standby operation is evaluated for YGN Units 3/4. The plant initial condition is determined within the EOP limitation as suitable to hot-standby mode and the transient scenario is prepared as relevant to evaluation of transient natural circulation. A 0.4% cold leg break with loss of off-site power is calculated with RELAP5/MOD3.2, whose predictability has been verified for SBLOCA natural circulation test, S-NC-8B. Through one hour transient analysis, it is found that the plant has its own decay heat removal capability by natural circulation following a LOCA, at hot-standby mode. Additional calculation is performed to investigate an effect of HPSI flow on natural circulation.

  • PDF

Numerical Analysis for Unsteady Thermal Stratified Turbulent Flow in a Horizontal Circular Cylinder

  • Ahn, Jang-Sun;Ko, Yong-Sang;Park, Byeong-Ho;Youm, Hag-Ki;Park, Man-Heung
    • Nuclear Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.405-414
    • /
    • 1996
  • In this paper, the unsteady 2-dimensional turbulent flow model for thermal stratification in a pressurizer surge line of PWR plant is proposed to numerically investigate the heat transfer and flow characteristics. The turbulence model is adapted to the low Reynolds number K-$\varepsilon$ model (Davidson model). The dimensionless governing equations are solved by using the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The results are compared with simulated experimental results of TEMR Test. The time-dependent temperature profiles in the fluid and pipe nil are shown with the thermal stratification occurring in the horizontal section of the pipe. The corresponding thermal stresses are also presented. The numerical result for thermal stratification by the outsurge during heatup operation of PWR shows that the maximum dimensionless temperature difference is about 0.83 between hot and cold sections of pipe well and the maximum thermal stress is calculated about 322MPa at the dimensionless time 28.5 under given conditions.

  • PDF

Ignition Characteristics According to Mixture ratio of Catalyst Ignitor using Green Propellant (친환경 추진제 점화기 설계 및 혼합비에 따른 점화 특성)

  • Chae, Byoung-Chan;Lee, Yang-Suk;Ko, Young-Sung;Kim, Yoo;Kim, Sun-Jin;Jeon, Young-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.111-114
    • /
    • 2009
  • A catalyst ignitor of small thrust engine using hydrogen peroxide and kerosene was designed and fabricated, which confirmed mass flow rate for design pressure through the water cold-flow test in this study. In order to investigate ignition performance, it was changed that mixture ratio for kerosene mass flow rate in a position which heat of hydrogen peroxide decomposition comes to a steady state. And we confirmed stable ignition property in a wide range of mixture ratio.

  • PDF

Design of cryostat for superconducting quadrupole magnets in In-Flight fragmentation separator

  • Choi, Y.S.;Chang, H.M.;Baudouy, B.;Kim, D.G.;Kim, J.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.62-66
    • /
    • 2015
  • The cryostat is designed for the superconducting quadrupole magnets to be used in a heavy-ion accelerator facility. The main accelerator is superconducting linac, which can accelerate a $^{238}U$ beam to 200 MeV/u (Mega electron voltage per nucleon). The cryostat for the magnet employs an innovative design primarily driven by the requirement of the compactness, user-friendliness and reliability. Also, several ancillary requirements such as background field, space restriction due to the beam line and cryostat structure need technical attentions. The development of the cryostat for three quadrupole magnets in the in-flight fragmentation separator is presented in the paper. The concept of cryogenic design is reported and the amount of cryogenic load is estimated by a relevant analysis. The structure of the cryostat to endure the heavy iron yoke including three quadrupole magnets is presented. In addition, the design as well as the performance test of the support link for the cold mass is described.

Characteristics of electric power for thermoelectric cooling & generating module (열전냉각소자와 열전발전소자의 발전특성)

  • 우병철;이희웅;이동윤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.448-451
    • /
    • 2000
  • The purpose of this study is to manufacture and test a thermoelectric generator which converts unused energy from close-at-hand sources, such as garbage incineration heat and industrial exhaust, to electricity. A manufacturing process and the properties of a thermoelectric generator are discussed before simulating the thermal stress and thermal properties of a thermoelectric module located between an aluminum tube and alumina plate. We can design the thermoelectric modules having the good properties of thermoelectric generation. Resistivity of thermoelectric module for thermoelectric generation consisting of 62 cells was 0.15-0.4$\Omega$ Developed thermoelectric modules can be expected th have better properties than thermoelectric cooling modules above $70^{\circ}C$ in temperature difference between hot and cold ends.

  • PDF

Improving the Corrosion Resistance of Cold-Rolled Carbon Steel by Treatment with a Hybrid Organic/Inorganic Coating Solution (유/무기 하이브리드 코팅액에 의한 냉간압연강판의 내식특성)

  • Kim, Jung-Ryang;Choi, Chang-Min;Nam, Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.405-412
    • /
    • 2012
  • In the past, a very popular way to reduce the corrosion rate of zinc was the use of chemical conversion layers based on $Cr^{+6}$. However, the use of chromium salts is now restricted because of environmental protection legislation. Previous research investigated the optimum corrosion resistance of galvanized steel treated with an organic/inorganic solution containing Si. The result showed that the optimum corrosion resistance occurred by heat treatment of $190^{\circ}C$ in 5 min. In this study, one organic and three hybrid organic/inorganic coating solutions were applied to cold-rolled (CR) carbon steel. The coatings were then evaluated for corrosion resistance under a salt spray test. The coating solutions examined in this study consisted of urethane-only, urethane-Si, urethane-Si-Ti, and urethane-Si-Ti-epoxy. The results of the 7 h salt spray test showed that the urethane-Si-Ti and urethane-Si-Ti-epoxy coating solutions had superior corrosion resistance on CR steel.

The Efficiency Characteristics of Electric Vehicle (EV) According to the Diverse Driving Modes and Test Conditions (다양한 주행모드 및 시험 조건에 따른 전기자동차 효율 특성)

  • LEE, MIN-HO;KIM, SUNG-WOO;KIM, KI-HO
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.1
    • /
    • pp.56-62
    • /
    • 2017
  • Although most electricity production contributes to air pollution, the vehicle organizations and environmental agency categorizes all EVs as zero-emission vehicles because they produce no direct exhaust or emissions. Currently available EVs have a shorter range per charge than most conventional vehicles have per tank of gas. EVs manufacturers typically target a range of 160 km over on a fully charged battery. The energy efficiency and driving range of EVs varies substantially based on driving conditions and driving habits. Extreme outside temperatures tend to reduce range, because more energy must be used to heat or cool the cabin. High driving speeds reduce range because of the energy required to overcome increased drag. Compared with gradual acceleration, rapid acceleration reduces range. Additional devices significant inclines also reduces range. Based on these driving modes and climate conditions, this paper discusses the performance characteristics of EVs on energy efficiency and driving range. Test vehicles were divided by low / high-speed EVs. The difference of test vehicles are on the vehicle speed and size. Low-speed EVs is a denomination for battery EVs that are legally limited to roads with posted speed limits as high as 72 km/h depending on the particular laws, usually are built to have a top speed of 60 km/h, and have a maximum loaded weight of 1,400 kg. Each vehicle test was performed according to the driving modes and test temperature ($-25^{\circ}C{\sim}35^{\circ}C$). It has a great influence on fuel efficiency amd driving distance according to test temperature conditions.

Coating Effect of Low Temperature Melting Bi-Sn Metalized Wood Composites on 10 Different Korean Wood Species (주요 국산재 10가지 수종에 대한 Bi-Sn 저온용융 합금주입 목재복합체의 도장 효과)

  • Park, Kye-Shin;Seo, In Soo;Lee, Hwa Hyoung;Kang, Seog Goo
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.223-232
    • /
    • 2014
  • To make metalized wood composites of 10 different korean wood species, it was tested by Low temperature melting Bi-Sn alloy injection method at high temperature and high pressure condition. Metalized wood composite of each wood species had light ash color, but still maintained its own natural wood grain and wood figures. It was evaluated on coating properties. Furthermore, it also was check on effect of coating as like a changes of main color, wood grain and wood figures. The results of test were following as; a coating properties as like a cold resistance, heat resistance, acid resistance, alkali resistance, durability of abrasion, and cross-cut test was proper on the conditions of the KS standard. And, In aspect of color changes, the metalized wood composites of 10 different korean wood species had a light ash color, but still maintained its own natural wood grain and wood figures. Also, the more weight per gain of alloy is, the more grey background of metalized wood composite is.

  • PDF