• Title/Summary/Keyword: heat-cold test

Search Result 292, Processing Time 0.034 seconds

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.

Development of Gear-Type Vane Dampers to Replace Link-Type Vane Dampers in Marine FD Fans (선박용 강제통풍 팬의 기어식 베인댐퍼 성능평가)

  • Hur, Nam-Soo;Jang, Sung-Cheol;Lee, Kyung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.4
    • /
    • pp.216-222
    • /
    • 2016
  • Thus, this study aimed to develop a gear-type vane damper in order to replace the link-type vane damper. To achieve this goal, the torque generated in a gear-type vane damper was analyzed, and a structural analysis was conducted. In addition, the fluid flow was analyzed according to the changes in the vane's angle, and experimental tests such as a dry-heat test and cold test were conducted considering the operating conditions of the vessels. Moreover, an appropriate actuator was selected for the developed gear-type vane damper, and studies on the reduction in the backlash due to the facing-pressure adjustment length and flow rate and leakage test due to the vane's angle were conducted.

Establishment of the design stress intensity value for the plate-type fuel assembly using a tensile test

  • Kim, Hyun-Jung;Tahk, Young-Wook;Jun, Hyunwoo;Kong, Eui-Hyun;Oh, Jae-Yong;Yim, Jeong-Sik
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.911-919
    • /
    • 2021
  • In this paper, the design stress intensity values for the plate-type fuel assembly for research reactor are presented. Through a tensile test, the material properties of the cladding (aluminum alloy 6061) and structural material (aluminum alloy 6061-T6), in this case the yield and ultimate tensile strengths, Young's modulus and the elongation, are measured with the temperatures. The empirical equations of the material properties with respect to the temperature are presented. The cladding undergoes several heat treatments and hardening processes during the fabrication process. Cladding strengths are reduced compared to those of the raw material during annealing. Up to a temperature of 150 ℃, the strengths of the cladding do not significantly decrease due to the dislocations generated from the cold work. However, over 150 ℃, the mechanical strengths begin to decrease, mainly due to recrystallization, dislocation recovery and precipitate growth. Taking into account the uncertainty of the 95% probability and 95% confidence level, the design stress intensities of the cladding and structural materials are established. The presented design stress intensity values become the basis of the stress design criteria for a safety analysis of plate-type fuels.

The Effect of Welding Residual Stress on Whole Structure with T-Joint RHS

  • Rajesh S. R.;Bang H. S.;Kim H.
    • International Journal of Korean Welding Society
    • /
    • v.5 no.1
    • /
    • pp.60-65
    • /
    • 2005
  • In the field of welding the mechanical behavior of a welded structure under consideration may be predicted via heat transfer and welding residual stress analysis. Usually such numerical analyses are limited to small regular mesh models or test specimens. Nevertheless, there is very few strength assessment of the whole structure that includes the effect of welded residual stress. The present work is based on the specialized finite element codes for the calculation of nonlinear heat transfer details and residual stress including the external load on the welded RHS (Rectangular Hollow Section) T-joint connections of the whole structure. First the thermal history of the combined fillet and butt-welded T-joint equal width cold-formed RHS are calculated using nonlinear finite element analysis (FEA) considering the quarter model of the joint. Then using this thermal history the residual stress around the joints has been evaluated. To validity the FEA result, the calculated residual stresses were compared with the available experimental results. The residual stress obtained from the quarter model is mapped to the full model and then to the whole structure model using FEM codes. The results from the FEM codes were exported to the commercial package for visualization and further analysis applying loads and boundary conditions on the whole structure. The residual stress redistribution along with the external applied load is examined computationally.

  • PDF

Numerical Simulation of Temperature and Stress Distribution in Mass Concrete with pipe cooling and Comparision with Experimental Measurements (매스콘크리트 시험체의 수화열 해석 및 실험)

  • 주영춘;김은겸;신치범;조규영;박용남
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.269-274
    • /
    • 1999
  • Various method have been developed for mass concrete structures to reduce the temperature increase of concrete mass due to exothermic hydration reactions of concrete compounds and thereby to avoid thermal cracks. One of the methods widely acceptable for practical use is pipe cooling, in which cooling is achieved by circulating cold water through thin-wall steel pipes embedded in the concrete. A numerical simulation was performed to investigate the effectiveness of pipe cooling. A three-dimensional finite element method was proposed to analyse the transient three-dimensional heat transfer between the hardening concrete and the cooling water in pipe and to predict the stress development during the curing process. The effects of the cement type and content and the environment were taken into consideration by the heat generation rate and the boundary conditions, respectively. In order to test the validity of the numerical simulation, a model RC structure with pipe cooling was constructed and the time-dependent temperature and stress distributions within the structure as well as the variation of the temperature of cooling water along the pipe were measured. The results of the simulation agreed well the experimental measurements. The results of this study have important implications for the optimal design of the cooling pipe layout and for the estimation of thermal stress in order to eliminate thermal cracks.

  • PDF

Effect of γ on the Uniform Corrosion of 202 Stainless Steel with Two Phases of γ and α (γ와 α' 2상 조직을 갖는 202 스테인리스강의 균일부식에 미치는 γ의 영향)

  • Kim, Y.H.;Heo, S.H.;Kim, S.H.;Lee, S.H.;Kang, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.28 no.4
    • /
    • pp.200-205
    • /
    • 2015
  • Effects of austenite on the uniform corrosion in the solution of $1\;N\;H_2SO_4$ were investigated through the electrochemical polarization test. Two phases structures of martensite and austenite were obtained by annealing treatment at the range of $500^{\circ}C{\sim}700^{\circ}C$ for 10min. in 70% cold-rolled 202 stainless steel. Volume fraction of reversed austenite increased rapidly with an increase of annealing temperature. Uniform Corrosion was occur mainly on martensite phase in 202 austenitic stainless steel with two phase of austenite and martensite. Corrosion current density increased with an increase of volume fraction of austenite, therefore uniform corrosion was affected by volume fraction of austenite

A Study on the Level of Recognition & Performance of Traditional Postpartal Care for postpartal Women in Postpartum Care Center (산후조리원 이용 산모의 산후조리 인지도와 수행도)

  • Park, Shim-Hoon;Kim, Hyun-Ok
    • Women's Health Nursing
    • /
    • v.8 no.4
    • /
    • pp.506-520
    • /
    • 2002
  • The purpose of this study is to research the degree of recognition & performance of traditional postpartal care for postpartal women and to provide the basic data for improvement of service in a postpartum care center. The respondents of this study were 100 women of 6 postpartum care centers within a C province from Oct. 20 to Dec. 10, 2000. The instruments of measure were used for collecting data on the degree of recognition & performance of traditional postpartal care developed by the researcher. Data analysis consisted of frequency, percentage, mean, standard deviation, paired t-test, t-test, ANOVA which are calculated by Scheffe test and Cronbach's alpha which is used as a reliance level by using a SPSS-PC+. The results of the study were as follows:1. The average score for the degree of recognition of traditional postpartal care(Sanhujori) for postpartal women was $3.09{\pm}.31$, and they recognized that it was important. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the argumentation of heat and avoidance of cold, handling with whole heart, and keeping clean, resting without working, eating well. 2. The average score for the degree of performance of traditional postpartal care (Sanhujori) for postpartal women was $2.81{\pm}.31$, and they performed that it was important, too. The methods which were ranked were as follows; Protecting the body from a harmful state, invigorating the body by the augumentation of heat and avoidance of cold, eating well, handling with whole heart, and keeping clean, resting without working. 3. There were significant differences statistically (paired-t=-8.39, p=.000) of the degree of recognition & performance of traditional postpartal care(Sanhujori) for the postpartal women. The degree of recognition was higher than the degree of performance. So, the recognition of traditional postpartal care (Sanhujori) was higher than the performance of it. 4. There were no statistical differences of the degree of recognition & performance of traditional postpartal care(Sanhujori) among the postpartal women's age, religion, job, educational background, delivery frequency, delivery method or the sex of baby. So, the Characteristics of the respondents were not influenced as far as the degree of recognition & performance of traditional postpartal care(Sanhujori). 5. There were significant differences statistically of the degree of performance of traditional postpartal care(Sanhujori) among the 5 postpartum care centers except 1 postpartum care center(p<.01). So, the recognition of traditional postpartal care(Sanhujori) was higher than the performance of traditional postpartal care(Sanhujori) in the 5 postpartum care centers. But there was performed as good as recognition in only 1 postpartum care center.

  • PDF

A Study on the Thermal Properties of Binary Eutectic Mixed PCM Using Polyethylene Glycol and 1,4-Butanediol (Polyethylene glycol과 1,4-Butanediol을 활용한 이원 공융혼합 PCM의 열적 특성에 관한 연구)

  • Jooyoung Park;Kitae Park;Jongchul Seo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.30 no.2
    • /
    • pp.101-106
    • /
    • 2024
  • Current cold chain logistics relying on organic or eutectic materials within the 2~8℃ range as secondary fluids often face limitations in heat storage capacity, necessitating high energy consumption and large volume capacity. An effective approach to address this challenge is by incorporating polymers to enhance the heat storage capacity of eutectic materials. In this study, we investigated the impact of polyethylene glycols (PEGs) on phase change materials using Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimeter (DSC), analyses of endothermic and exothermic phase change processes, and an accelerated thermal cycling test. Our findings indicate that the introduction of PEGs into the phase change materials can lead to improvements in latent heat, thermal conductivity, and 2~8℃ retention time. This enhancement is attributed to the high latent heat and thermal conductivity of the polymer, along with its ability to inhibit crystal formation in the eutectic mixture.

Orofacial Thermal Quantitative Sensory Testing (QST): A Study of Healthy Korean Women and Sex Difference

  • Ahn, Sung-Woo;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.40 no.3
    • /
    • pp.96-101
    • /
    • 2015
  • Purpose: Thermal sensory test as an essential part of quantitative sensory testing (QST) has been recognized as a useful tool in the evaluation of the trigeminal nerve function. Normative data in the orofacial region have been reported but the data on differences in the test site, sex and ethnicity are still insufficient. Thus, this study aimed to investigate the normal range of orofacial thermal QST data in the healthy Korean women, and assess sex difference of thermal perception in the orofacial regions. Methods: Thermal QST was conducted on 20 healthy women participants (mean age, 26.4 years; range, 21 to 34 years). The thermal thresholds (cold detection threshold, CDT; warm detection threshold, WDT; cold pain threshold, CPT; and heat pain threshold, HPT) were measured bilaterally at the 5 trigeminal sites (the forehead, cheek, mentum, lower lip and tongue tip). The normative thermal thresholds of women in the orofacial region were evaluated using one-way ANOVA and compared with the previously reported data from age- and site-matched 30 healthy men (mean age, 26.1 years; range, 23 to 32 years) using two-way ANOVA. One experienced operator performed the tests of both sexes and all tests were done in the same condition except the time variability. Results: Women showed significant site differences for the CDT (p<0.001), WDT (p<0.001), and HPT (p=0.047) in the orofacial region. The CDT (p<0.001) and the CPT (p=0.007) presented significant sex difference unlike the WDT and the HPT. Conclusions: The thermal sensory evaluation in the orofacial region should be considered in the context of site and sex and the normative data in this study could be useful for assessment of the sensory abnormalities in the clinical setting.

Radioactive Wastes Vitrification Using Induction Cold Crucible Melter: Characteristics of Vitrified Form (유도 가열식 저온용융로를 이용한 방사성페기물 유리화: 유리 고화체 특성)

  • 김천우;박은정;최종락;지평국;최관식;맹성준;박종길;신상운;송명재
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.576-581
    • /
    • 2002
  • In order to simultaneously vitrify the ton Exchange Resin(IER) and Dry Active Waste(DAW) generated from the Nuclear Power Plants, a vitrification pilot test was conducted using an induction cold crucible melter. The PCT result evaluating the chemical durability of the vitrified from showed that the final glass was more durable than the benchmark glass. Liquidus temperature for the final vitrified form was 1048 K(775$\^{C}$) fur heat treatment experiments. The value of the compressive strength for the vitrified form was ninety times higher than the regulation limit, 34 kg/㎠. The glasses on bottom, middle and top of the CCM were homogeneous with no secondary phase. The precipitation of the magnetic metal phase was able to be avoided by simultaneously fEeding of DAW with IER containing strongly reducing organics. Volume reduction factor of 74 was achieved through the vitrification Pilot test for mixed waste.