• 제목/요약/키워드: heat-cold test

검색결과 292건 처리시간 0.038초

Bonding of nano-modified concrete with steel under freezing temperatures using different protection methods

  • Yasien, A.M.;Bassuoni, M.T.
    • Computers and Concrete
    • /
    • 제26권3호
    • /
    • pp.257-273
    • /
    • 2020
  • Concrete bond strength with steel re-bars depends on multiple factors including concrete-steel interface and mechanical properties of concrete. However, the hydration development of cementitious paste, and in turn the mechanical properties of concrete, are negatively affected by cold weather. This study aimed at exploring the concrete-steel bonding behavior in concrete cast and cured under freezing temperatures. Three concrete mixtures were cast and cured at -10 and -20℃. The mixtures were protected using conventional insulation blankets and a hybrid system consisting of insulation blankets and phase change materials. The mixtures comprised General Use cement, fly ash (20%), nano-silica (6%) and calcium nitrate-nitrite as a cold weather admixture system. The mixtures were tested in terms of internal temperature, compressive, tensile strengths, and modulus of elasticity. In addition, the bond strength between concrete and steel re-bars were evaluated by a pull-out test, while the quality of the interface between concrete and steel was assessed by thermal and microscopy studies. In addition, the internal heat evolution and force-slip relationship were modeled based on energy conservation and stress-strain relationships, respectively using three-dimensional (3D) finite-element software. The results showed the reliability of the proposed models to accurately predict concrete heat evolution as well as bond strength relative to experimental data. The hybrid protection system and nano-modified concrete mixtures produced good quality concrete-steel interface with adequate bond strength, without need for heating operations before casting and during curing under freezing temperatures down to -20℃.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

대용량 청정 공기 가열 장치 설계 (Design of Large Capacity Clean Air Heater)

  • 김정우;정광수;전민준;이규준
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.115-118
    • /
    • 2010
  • 공기 가열 장치는 크게 연소식과 열교환식 2가지가 있으며, 본 논문은 공기를 오염시키지 않은 열교환 방식인 청정 공기 가열 장치의 설계 방법을 기술하였다. 가열 장치는 크게 연소기 (Burner), 가열로 (Furnace), 열교환기 (Heat Exchanger), 배기구로 구성되어 되며, 가열되는 공기 유량과 입/출구 온도값으로부터 가열원인 연소기의 열용량과 연소기 연료인 LNG의 소요량을 구한다. 열교환기 내부에서 연소기의 뜨거운 연소가스와 가열되는 차가운 공기간의 열매체를 통한 간접 열교환이 이루어지므로, 가열되는 공기의 입/출구 온도에서 열교환기의 용량, 크기, 작동 최대 온도를 얻을 수 있게 된다.

  • PDF

알레르기 비염 환자의 변증별 자율신경계 특성 분석 연구 (Autonomic Conditions in Allergic Rhinitis Depending on Various Pattern Identifications)

  • 최은지;장수빈;이규진;윤영희;최인화;고성규
    • 한방안이비인후피부과학회지
    • /
    • 제27권4호
    • /
    • pp.110-120
    • /
    • 2014
  • Objectives : We performed a clinical study to investigate autonomic conditions in persistent allergic rhinitis depending on various pattern identifications and the availability of heart rate variability (HRV) as a pattern identification diagnostic tool. Methods : 32 patients with persistent allergic rhinitis were asked to interview with doctor of Korean Medicine and perform the four pattern questionnaires (Cold-Heat Pattern, Phlegm Pattern, Yin Deficiency pattern, bloodstasis pattern). Then, they were examined their autonomic conditions with heart rate variability test. Results : Patients were classified as three pattern groups (Lung-stomach heat, Lung qi deficiency cold, Lung-spleen qi deficiency) by doctor. In the Lung qi deficiency cold group, Total power of the HRV (TP) and the power of the low frequency component (LF) significantly higher than in the Lung-stomach heat or Lung-spleen qi deficiency group (P < 0.05). Also, Patients were classified as 8 pattern groups (Cold/Heat, Phlegm/Non-phlegm, Yin deficiency/Non-yin deficiency, Bloodstasis/Non-bloodstasis) by four pattern questionnaires. Only in the Yin deficiency group, the power of the low frequency component (LF) significantly lower than in the Non-yin deficiency group (P < 0.05). There were not any significant differences in the rest groups. Conclusions : The result may provide that HRV doesn't reflect well the differences in the various pattern groups, and the HRV's availability is low. Continuous studies are needed to develop the objective and standardized pattern identification diagnostic tool for allergic rhinitis.

R410A 대체냉매 R32와 R454B의 미세핀 관내 응축 열전달 (Condensation Heat Transfer of R32 and R454B Inside a Microfin Tube as an Alternative Refrigerant to R410A)

  • 안드리아스 카라지오기스;죠지 히노플로스;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.413-418
    • /
    • 2022
  • This paper presents two-phase condensation heat transfer and pressure drop characteristics of R32 and R454B as an alternative refrigerant to R410A in a 9.52 mm OD microfin tube. The test facility has a straight, horizontal test section with an active length of 2.0 m and is cooled by cold water circulated in a surrounding annular space. The heat transfer coefficients of the annular space were obtained using the modified Wilson plot method. Average condensation heat transfer coefficient and pressure drop data are presented at the condensation temperature of 35℃ for the range of mass flux 100-400 kg/m2s. The average condensation heat transfer coefficients of R32 refrigerant are 35-47% higher than R410A at the mass flux considered in the study, while R454B data are similar to R410A. The average pressure drop of R32 and R454B are much higher than R410A and they are 134-224% and 151-215% of R410A, respectively. R32 and R454B have relatively low GWP and high heat transfer characteristics, so they are suitable as alternatives for R410A.

복부에 슬릿이 있는 박판냉간성형형강 스터드의 압축강도 (The Compressive Strength of Thin-Walled Cold-Formed Steel Studs with Slits in the Web)

  • 권영봉;서응규;임덕만;김갑득;권인규
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.189-197
    • /
    • 2012
  • 벽식 스틸하우스 벽체의 구조재로 적용되어 오고 있는 박판냉간성형형강 스터드의 경우 열교현상에 의한 단열상의 문제를 가지고 있기 때문에 추가적인 단열재의 사용이 요구된다. 이러한 단열 문제를 해결하기 위하여 웨브에 슬릿이 배치된 냉간성형강 단열스터드가 개발되었다. 그러나 슬릿의 배치로 인하여 단면강도 산정은 대단히 어려운 문제점이 되고 있다. 본 논문에는 단열스터드의 압축강도 및 구조적인 거동에 대한 실험 및 해석적인 연구결과를 기술하였다. 슬릿의 길이, 간격 및 배열형태를 달리하는 세 종류의 단열스터드에 대한 압축실험을 단면의 파괴 시까지 수행하였으며, 실험 및 해석결과에 근거하여 복부에 슬릿이 있는 냉간성형강 스터드에 적용하기 위한 단순한 형태의 강도 산정방법을 제안하였다. 제안된 강도산정법에서는 단열스터드를 등가두께의 슬릿이 없는 일반스터드로 대치하고, 이 등가단면에 직접강도법을 적용하여 단열스터드의 공칭압축강도를 산출한다. 제안된 강도산정방법은 단열스터드 실험결과와 비교하여 검증하였다.

고강도.초유동 콘크리트의 동절기 경화이력에 관한 실험적 연구 (Experimental Study on Hardening Process of High-Strength and High-Flowable Concrete in Cold Weather)

  • 윤영수;이승훈;노윤호;안창남;성상래;백승준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.95-100
    • /
    • 1996
  • This paper presents the experimental study on hardening process of high-strength and high-flowable concrete. The experiments were performed to investigate any unfavorable construction situations since the actual concrete placement has been scheduled in cold weather period, so that the high quality concrete construction is convinced to be successfully carried out. The tests were conducted using 600nm and 1000nm height of steel tube to simulate the practical concrete filled steel tube columns according to the following variables as: the categories of chemical admixtures, curing temperatures and curing schemes. The test results were analyzed in terms of hardening speed, internal heat of hydration and history of strength gain. This paper emphasizes the importance of curing schemes on durability and the use of hardening accelerators on strength gain.

  • PDF

이중관 배기메니폴드의 HC저감효과 및 열특성에 관한 연구 (A Study on the Reduction of HC and Heat Characteristics of the Dual Pipe Exhaust Manifold)

  • 박경석;허형석
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.103-111
    • /
    • 2001
  • During cold-start period, the reduction of exhaust emissions is a challenging task. To decrease harmful gaseous substances such as HC, it is necessary to realize a fast catalyst warm-up. In this study, the performance of dual pipe exhaust system have been carried out through different test mode. From measurement of gas temperature and HC concentration, the following conclusions were derived ; 1) Compared with single pipe, dual pipe exhaust system remarkably increase temperature of exhaust gas going through M.C.C(Main Catalytic Converter). 2) W.C.C.(Warm-up Catalytic Converter) also decreases HC emission. To reduce HC emission, it is helpful to use W.C.C. as well as dual pipe exhaust system. 3) Using finite element method, it is shown that inner parts have much higher distribution of temperature than outer parts.

  • PDF

메탄엔진 연소시험설비 구축 및 예비 시험들 (Methane Engine Combustion Test Facility Construction and Preliminary Tests)

  • 강철웅;황동현;안종현;이준서;이다인;안규복
    • 한국추진공학회지
    • /
    • 제25권3호
    • /
    • pp.89-100
    • /
    • 2021
  • 본 논문에서는 메탄엔진 연소시험을 위한 연소시험설비 구축과 예비 시험들을 다루었다. 먼저 액체산소/기체메탄을 추진제로 사용하는 1 kN급 연소기 연소시험설비를 설계 및 구축하였다. 연소시험 전 각 추진제 라인의 수류시험 및 토치 점화기/애프터버너의 점화시험을 통해 연소시험설비의 추진제 공급 안정성, 제어 및 계측시스템 작동, 성공적인 점화를 검증하였다. 마지막으로 예비 연소시험을 수행하여 연소기 시제품의 연소 효율, 열유속, 연소 안정성을 측정하였다. 구축된 연소시험설비는 메탄엔진 연소기 기초연구 및 개발에 유용하게 활용될 예정이다.

한랭지용 열펌프의 저온난방 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Heat Pump for the Cold Climate)

  • 주정동;배경수;황영규;이윤용;정규하;오상경
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.39-46
    • /
    • 2005
  • The present study concerns an experimental study of a R-22 heat pump system consisted of liquid and liquid heat exchangers. The test was performed for various systems of a single-, tandem-, and two stage-cycle at the same environmental conditions of temperature. Various experiments of the heat pump system were peformed to compare the heating capacity and COP, when the outdoor temperature is near $-15^{\circ}C$ and the indoor temperature is $20^{\circ}C.$ As the results of the present study, the system of Tandem(parallel) cycle showed the best heating performance, while the discharge temperature of refrigerant was too high. In case of the system of two stage cycle, the performance characteristics were significantly improved by employing the inter cooler.