• Title/Summary/Keyword: heat transfer correlations

Search Result 365, Processing Time 0.029 seconds

Effects of Tube Diameter and Surface Sub-Cooling Temperature on R1234ze(E) and R1233zd(E) Film Condensation Heat Transfer Characteristics in Smooth Horizontal Laboratory Tubes (수평 평활관에서 관직경 및 표면 과냉도가 R1234ze(E) 및 R1233zd(E) 막응축 열전달에 미치는 영향)

  • Jeon, Dong-Soon;Ko, Ji-Woon;Kim, Seon-Chang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.5
    • /
    • pp.231-238
    • /
    • 2017
  • HFO refrigerants have recently come to be regarded as promising alternatives to R134a for use in turbo chillers. This study provides results from experiments evaluating the film condensation heat transfer characteristics of HFO refrigerants R1234ze(E) and R1233zd(E) on smooth horizontal laboratory tubes. The experiments were conducted at a saturation vapor temperature of $38.0^{\circ}C$ with surface sub-cooling temperatures in the range of $3{\sim}15^{\circ}C$. We observe that the film condensation heat transfer coefficient decreases as surface sub-cooling temperatures increase. In the case of laboratory tubes with a diameter of 19.05 mm, the film condensation heat transfer coefficients of R1234ze(E) and R1233zd(E) were approximately 11% and 20% lower than those of R134a, respectively. Furthermore, our investigation of the effect of tube diameter on film condensation heat transfer coefficients, demonstrates an inverse relationship where the film condensation heat transfer coefficient increases as laboratory tube diameter decreases. We propose experimental correlations of Nusselt number for R1234ze(E) and R1233zd(E), which yield a ${\pm}20%$ error band.

Design of a Pin-Fin Structure in a Channel Considering the Heat Transfer and Pressure Drop Characteristics (열전달 및 압력강하 특성을 고려한 채널 내 핀-휜 구조물의 설계)

  • Shin, Jee-Young;Son, Young-Seok;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.459-467
    • /
    • 2006
  • Rapid development of electronic technology requires small size, high density packaging and high power in the electronic devices, which results in more heat generation. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the current state-of-the-art electronic equipment. The aim of the present study is to find out the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices through the analysis and experiment. Various configuration of the pin-fin array is selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. Experimental results are compared with the analyses and correlations of several researchers. Finally, the design guide are provided for the required pressure drop and/or the heat transfer characteristics of the heat exchanger.

Modifications and Assessment of RELAP5/MOD3.2 for HANARO Thermal-Hydraulic Safety Analyses

  • Gee Yang Han;Kwi Seok Ha
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.455-467
    • /
    • 2002
  • RELAP5/MOD3.2 was modified to perform the thermal-hydraulic safety analysis for HANARO transients. Several aspects of RELAP5/MOD3.2 were modified or replaced by new features to properly simulate the unique HANARO characteristics such as the finned fuel element, the cooling mechanisms by both plate type heat exchanger and the natural circulation. Especially, the heat transfer packages were modified to be more appropriate for the safety analysis and the heat transfer models were developed for the plate type heat exchanger as well as natural circulation through the pool water. This modified version of RELAP5/MOD3.2 is renamed as RELAP5/HANARO. The thermal-hydraulic simulations of the single fuel pin test and plate type heat exchanger were peformed to assess the realistic predicting capabilities of RELAP5/HANARO and compared with experimental results and manufacturer's data in this paper. In addition, the natural circulation experiment using the scaled bundle was simulated to validate the capability of RELAP5/HANARO. The simulation results show almost similar trend with experimental data. Therefore, it is proved that RELAP5/HANARO has a confidence to use for the safety analyses of HANARO.

EFFECTS OF CHANNEL ASPECT RATIO ON FLOW AND HEAT TRANSFER CHARACTERISTICS OF PRIMARY SURFACE HEAT EXCHANGER FOR ORC (유기랭킨사이클(ORC)을 위한 주전열면 열교환기의 채널 종횡비에 따른 유동 및 열전달 특성)

  • Sung, M.J.;Ahn, J.
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.35-40
    • /
    • 2013
  • A series of numerical simulation has been carried out to study thermo-hydraulic characteristics of a primary surface type heat exchanger, which is designed for the evaporator and condenser of a geothermal ORC. Working fluid is geothermal water at hot side and R-245fa, which is a refrigerant designed for ORC, at cold side. Aspect ratio of the channel and Reynolds number are considered as design parameters. Nusselt number is presented for the Reynolds number ranging from 50 to 150 and compared to existing correlations. The result shows that higher aspect ratio channel gives better heat transfer performance within the range of investigation.

Analysis on the Cooling Characteristics of a Channel with Pin-Fin Structure (핀-휜 구조물을 이용한 채널의 냉각특성 해석)

  • 신지영;손영석;이대영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.667-673
    • /
    • 2003
  • Recent trends in the electronic equipment indicate that the power consumption and heat generation in a chip increase as the components are miniaturized and the computing speed becomes faster. Suitable heat dissipation is required to ensure the guaranteed performance and reliable operation of the electronic devices. The aim of the present study is to investigate the forced-convective thermal-hydraulic characteristics of a pin-fin heat exchanger as a candidate for cooling system of the electronic devices. The influence of the structure of the pin-fin assembly on heat transfer is investigated by porous medium model. The results are compared with the experimental data or correlations of several researchers for the heat transfer coefficients for the channel flow with pin-fin arrays. Finally, the effects of design parameters such as the pin-fin diameter and the spacing are examined.

An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator (맥동관 냉동기 열교환기에 관한 실험적 연구)

  • 남관우;정상권;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Air-side Performance of Aluminum Heat Exchangers at Different Inclination Angles (경사지게 설치된 평행류형 알루미늄 열교환기의 공기측 전열 성능)

  • Kim, Do-Young;Cho, Jin-Pyo;Kim, Nae-Hyun;Park, Nae-Hyun;Hwang, Jun-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • The effect of inclination angle on the heat transfer and pressure drop characteristics of the brazed aluminum heat exchangers is experimentally investigated. Three samples having different fin pitches(1.25, 1.5 and 2.0 mm) were tested. Results show that heat transfer coefficient is not affected by the inclination angle. However, the friction factor increases as the inclination angle increases with negligible difference between the forward and backward inclination. Both the heat transfer coefficient and the friction factor are the smallest at $F_p=1.5mm$, followed by $F_p=2.0mm$ and 1.25mm. Possible explanation is provided considering the louver layout. Comparison with existing correlations is also made.

Study on longitudinal variation of subcooling with high elevated liquid line in a modular heat pump system (모듈형 동시냉난방 열펌프의 장배관/고낙차에 따른 액선 과냉도 변화에 대한 연구)

  • Shin, Kwang-Ho;Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang;Park, Sung-Ryung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1255-1260
    • /
    • 2008
  • This study is simulation of high elevated liquid line of a modular heat pump system to observe longitudinal subcooling variation. In a high elevated tube, subcooled refrigerant(R410A) through a condenser changes its states by heat transfer with surrounding air and by pressure drop from elevation. In this study, the liquid line was simulated through correlations of heat transfer and pressure drop for the variation from single-phase into two-phase flow. Pressure drop, heat transfer rate and vapor quality were calculated as key parameters. Two-phase turning heights and variations of the key parameters were confirmed from the simulation. As a result, high elevation of liquid line has great influence on upward flow, which requires additional equipment to compensate the variation.

  • PDF

Heat Transfer in the Passive Containment Cooling System (수동형 격납용기 냉각계통에서의 열전달)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.281-291
    • /
    • 1995
  • The objective of this work is to obtain the experimental data for the heat transfer processes occurring both on the inside and outside surfaces of containment steel wall with dry and wet outer surface conditions in the passive containment cooling system. The test model represented a 60$^{\circ}$ section of a containment vessel based on the AP 600 geometry. Major linear dimensions of the test model ore reduced tv a factor of ten. To simulate the decay heat a steam generator heated by electricity was placed in the test model. The maximum heat flux was 8.91 kW/$m^2$. Two types of tests were performed. The one was the tort on the natural convection of air without water film flow. The other was the evaporative heat transfer test with the falling water film flow and natural air draft. no test result shooed that the heat transfer capability by the natural convection from the containment to the air without oater film flow was limited at about 1.48 kW/$m^2$ heat flux. It was found that the heat removal capability was remarkably enhanced in the tests with the waster film flow and air draft. The obtained heat transfer data ore compared with the existing correlations.

  • PDF