• Title/Summary/Keyword: heat split

Search Result 84, Processing Time 0.031 seconds

Fundamental Study on The Heat Input Model of Hybrid Welding for The Finite Element Analysis (유한요소해석을 위한 하이브리드용접 입열모델 선정에 관한 기초적 연구)

  • 방한서;김영표
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.36-38
    • /
    • 2003
  • In order to understand the basic knowledge on the model of heat source in hybrid welding, authors have conducted finite element analysis to calculate heat distribution using three heat source models of non-split type and split type(Volume, Volume-Volume, Volume-Surface). From the research result, we can confirm that Volume-Volume heat source of split type is suitable for the analysis of heat distribution.

  • PDF

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Melting of Ice on the Heating Plate with Split Fins

  • Hong, Hi-Ki;Kim, Moo-Geun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.1-7
    • /
    • 2001
  • One of the important applications of a contact melting process is a latent thermal energy storage system owing to its high heat flux and small temperature variation. In some previous works, the split fins have been employed in order to enhance the melting rate. In the present work, the direct contact melting was experimentally investigated using an ice as specimen for both split and non-split fins. It was shown that the contact melting by split fins increases the melting rate compared to that of non-split ones.

  • PDF

Melting of ice on the heating plate with split fins (분할된 핀붙이 전열면상에서의 얼음의 용융)

  • 홍희기;김무근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.67-74
    • /
    • 2000
  • One of the important application of a contact melting process is a latent thermal energy storage owing to its high heat flux. In some previous works, the split fins have been employed in order to enhance the melting speed. In the present work, the close contact melting was experimentally investigated using an ice as specimen for both split and non-split fins. It was shown that the contact melting by split fins increases the melting rate compared to that of non-split ones.

  • PDF

A Study of the Effects of Split Injection on PM and NOx emission in a Common-Rail DI Diesel Engine (Common-Rail DI Diesel Engine에서 Split Injection이 PM및 NOx 배출에 미치는 영향에 관한 기초 연구)

  • Choi, Jin-Ho;Chung, Jae-Wook;Chang, Dong-Hoon;Lee, Jae-Wook;Chun, Kwang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.225-230
    • /
    • 2003
  • The major purpose of this study is to find the optimized split injection quantities and dwell angles for PM reduction without increasing NOx. The tests were performed on a Common-Rail DI Diesel Engine to obtain optimum injection timing and duration. In this study, total injection quantities were divided into the ratio of 25-75%, 50-50% and 75-25%. NOx and PM were measured on the condition of the same bsfc by increasing dwell angles. It was found that the split injection reduced NOx with dwell angle increase. For 50_50, 75_25% split injection cases, PM was reduced with 10 to 12(CAD) dwell angles. For 25_75% split injection 33% PM reduction was achieved with 8 to 12(CAD) dwell angles.

  • PDF

Performance of A Three-Stage Condensation Heat Pump

  • Lee, Yoon-Hak;Jung, Dong-Soo;Kim, Chong-Bo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.55-68
    • /
    • 1999
  • In this study, computer simulation programs were developed for single-stage, two-stage, and three-stage condensation heat pumps and their performance with CFC11, HCFC123, HCFC141b was examined under the same external conditions. The results showed that the coefficient of performance(COP) of an optimized 'non-split type' three-stage condensation heat pump is 25-42% higher than that of a conventional single-stage heat pump. The increase in COP, however, differed among the fluids tested. The improvement in COP is largely due to the decrease in average LMTDs in condensers, which results in the decrease in thermodynamic irreversibility in heat exchange process. For the three-stage heat pump, the highest COP is achieved when the total condenser area is evenly distributed among the three condensers. For the two-stage heat pump, however, the optimum distribution of the total condenser area varies with an individual working fluid. For the three-stage system, 'splitting the condenser cooling water'for the use of intermediate and high pressure subcoolers helps increase the COP further. When the individual cooling water entering the intermediate and high pressure subcoolers is roughly 10% of the total condenser cooling water, the maximum COP is achieved showing roughly an 11% increase in COP as compared to that of the 'non-split type' heat pump.

  • PDF

The behaviour of structures under fire - numerical model with experimental verification

  • Toric, Neno;Harapin, Alen;Boko, Ivica
    • Steel and Composite Structures
    • /
    • v.15 no.3
    • /
    • pp.247-266
    • /
    • 2013
  • This paper presents a comparison of results obtained by a newly developed numerical model for predicting the behaviour of structures under fire with experimental study carried out on heated and simply supported steel beam elements. A newly developed numerical model consists of three submodels: 3D beam model designed for calculating the inner forces in the structure, 2D model designed for calculation of stress and strain distribution over the cross section, including the section stiffness, and 3D transient nonlinear heat transfer model that is capable of calculating the temperature distribution along the structure, and the distribution over the cross section as well. Predictions of the calculated temperatures and vertical deflections obtained by the numerical model are compared with the results of the inhouse experiment in which steel beam element under load was heated for 90 minutes.

Temperature and Heat Split Evaluation of Annular Fuel (이중냉각핵연료 온도 및 열유속 분리 평가)

  • Yang, Yong-Sik;Chun, Tae-Hyun;Shin, Chang-Hwan;Song, Kun-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2236-2241
    • /
    • 2008
  • The surface heat flux of nuclear fuel rod is the most important factor which can affect safety of reactor and fuel. If fuel rod surface heat flux exceeds the CHF(${\underline{C}}ritical$ ${\underline{H}}eat$ ${\underline{F}}lux$), fuel can be damaged. In case of double cooled annular fuel, which is under developing, contains two coolant channels. Therefore, a generated heat in the fuel pellet can move to inner or outer channel and heat flow direction is decided by both sides heat resistance which varied by dimension and material property change which caused by temperature and irradiation. The new program(called DUO) was developed. For the calculation of surface heat flux, a both sides convection by inner/outer coolant, s gap temperature jump and conduction in the fuel are modeled. Especially, temperature and time dependent fuel dimension and material property change are considered during the iteration. A sample calculation result shows that the DUO program has sufficient performance for annular fuel thermal hydraulics design.

  • PDF

An Experimental Study on Improved Fuel Economy and Lower Exhaust Emissions of New Automotive Engine adopting Split Cooling System

  • Oh, C.S.;Lee, J.H.;Shin, S.Y.;Kim, W.T.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.407-408
    • /
    • 2002
  • This paper presents a split cooling system for a new inline 4-cylinder automotive engine. The split cooling system circulates coolant to the cylinder head and cylinder block separately. The coolant flow in the cylinder block is controlled by a $2^{nd}$ Thermostat installed at the outlet of cylinder block. The $2^{nd}$ thermostat closes when the coolant temperature is low. And this makes the coolant flow in cylinder block nearly stagnant, thereby reducing the coolant-side heat transfer coefficient and raising cylinder bore temperature. The $2^{nd}$ thermostat starts to open when the coolant temperature reaches a specified temperature. The test results on engine dynamometer show improved fuel economy and lower exhaust emission which result from the decrease in friction works and cooling loss. Also, several vehicle tests, with application of the new engine have been performed. Fuel economy improvement of 0.5{\sim}2.0%$ yields from different test modes and details are discussed in this paper.

  • PDF

Enthalpy Rise for Pressure Loss of Spacer Grids of Dual Coolant Fuel (이중냉각연료에서 지지격자의 압력손실에 대한 엔탈피 증가)

  • Chun, Kun-Ho;Chun, Tae-Hyun;Shin, Chang-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3473-3478
    • /
    • 2007
  • A dual side cooling annular fuel having internal and external coolant channels has many advantages basically due to low fuel temperature and high DNBR margin, which can make a significant increase of core power density possible. So recently a 12x12 square annular fuel array was proposed for the fuel assembly to be reloaded without structural interference with operating reactors of OPR-1000s. Even through the inherent potential of the annular fuel on the high power density, it may be seriously eroded in the case of a severe unbalanced mass flux split to the internal and external channels in standpoint of DNB. Mass flux split is determined pressure drop characteristics between inner and outer channels. The spacer grids binding fuel array influence greatly the pressure drop in outer channels and the mass flux split. As an important factor of DNB behavior, the enthalpy differences at both channel exits were evaluated using the mass flux splits.

  • PDF