• Title/Summary/Keyword: heat source/sink

검색결과 124건 처리시간 0.026초

시설원예 냉난방을 위한 온도차에너지 열원용 충적대수층 강변여과수 개발 (Riverbank Filtration Well Development for a Heat Source/Sink of Ground Water Heat Pumps)

  • 조용;이남영;이송이;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.171.1-171.1
    • /
    • 2010
  • Riverbank filtration wells have been developed to supply a heat source/sink of water in the alluvium aquifer to ground water heat pumps for cooling and heating of a green house. In order to look for an appropriate site to carry out the research, two sites of Jinju and Gumi areas were investigated. In the results of the electrical resistivity surveys, Jinju and Gumi areas have the alluvium aquifer in the depth of 6~17 m and 10~20 m under the ground respectively. Two boreholes have been drilled in each site of both areas. The averaged water level at Jinju site is about 3 m under the ground, and 3.5 m and 6.5 m of sandy gravel aquifer layers are existed in each site. While Gumi site has 10 m water level and 2.5 m and 4.6 m of sandy gravel aquifer. Therefore, it is expected that $1,000m^3$/day of water could be withdrawn at Jinju site rather than Gumi site.

  • PDF

수치 해석을 이용한 단일 마이크로채널의 단면 가열 조건의 열전달 특성에 관한 연구 (Investigation of Heat Transfer in Microchannel with One-Side Heating Condition Using Numerical Analysis)

  • 최치웅;허철;김동억;김무환
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.986-993
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method far high density electronic devices. The cross-sectional shape of MEMS based microchannel heat sink is limited to triangular, trapezoidal, and rectangular due to their fabrication method. And heat is added to one side surface of heat source. Therefore, those specific conditions make some complexity of heat transfer in microchannel heat sink. Though many previous research of conjugate heat transfer in microchannel was conducted, most of them did not consider heat loss. In this study, numerical investigation of conjugate heat transfer in rectangular microchannel was conducted. The method of heat loss evaluation was verified numerically. Heat distribution was different for each wall of rectangular microchannel due to thermal conductivity and distance from heat source. However, the ratio of heat from each channel wall was correlated. Therefore, the effective area correction factor could be proposed to evaluate accurate heat flux in one side heating condition.

열원의 대칭 배열에 따른 압출형 히트싱크의 방열성능 연구 (Effects of Symmetrically Arranged Heat Sources on the Heat Release Performance of Extruded-Type Heat Sinks)

  • 구민예;신헌충;이교우
    • 대한기계학회논문집B
    • /
    • 제40권2호
    • /
    • pp.119-126
    • /
    • 2016
  • 본 연구는 실험적인 방법과 열유동 해석 방법을 사용하여 대용량 압출형 히트싱크의 방열성능에 미치는 열원 대칭배열의 영향을 고찰하고, 이를 바탕으로 제조원가가 낮은 고효율의 히트싱크를 제안하고자 한다. 실험결과를 통해서 유사한 유효 유동단면적을 가지는 경우에 히트싱크의 전열면적이 방열성능에 큰 영향을 줌을 확인할 수 있었으며, 히트싱크의 양면 모두를 이용하는 방열이 훨씬 효과적인 방열이 가능함을 알 수 있었다. 또한, 대칭으로 열원을 배치한 경우가 비대칭 배치보다 효율적으로 방열됨을 알 수 있었다. 해석연구의 결과를 통해서는 실험결과와 정성적으로는 유사한 경향을 확인할 수 있었으며, 실험연구에서 확인하지 못한 질량유량별 및 투입열량별 추이, 단면과 양면 사용의 정량적 비교 등이 가능하였다.

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

분무 증발을 이용한 칩 냉각 향상에 대한 수치적 연구 (NUMERICAL STUDY OF CHIP COOLING ENHANCEMENT WITH EVAPORATING MIST FLOW)

  • 노상은;김동철;손기헌
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.9-16
    • /
    • 2013
  • The heat transfer enhancement of heat sink with mist flow is studied numerically by solving the conservation equations for mass, momentum and energy in the continuous and dispersed phases. A Lagrangian method is used for tracing dispersed water droplets in the heat sink and an Eulerian species transport model for air and steam mixture. The continuous and dispersed phases are interacted with the drag and evaporation source terms. The computed results show that addition of evaporating mist droplets enhances the cooling performance of heat sink significantly.

INFLUENCE OF CONSTANT HEAT SOURCE/SINK ON NON-DARCIAN-BENARD DOUBLE DIFFUSIVE MARANGONI CONVECTION IN A COMPOSITE LAYER SYSTEM

  • MANJUNATHA, N.;SUMITHRA, R.;VANISHREE, R.K.
    • Journal of applied mathematics & informatics
    • /
    • 제40권1_2호
    • /
    • pp.99-115
    • /
    • 2022
  • The problem of Benard double diffusive Marangoni convection is investigated in a horizontally infinite composite layer system consisting of a two component fluid layer above a porous layer saturated with the same fluid, using Darcy-Brinkman model with constant heat sources/sink in both the layers. The lower boundary of the porous region is rigid and upper boundary of the fluid region is free with Marangoni effects. The system of ordinary differential equations obtained after normal mode analysis is solved in closed form for the eigenvalue, thermal Marangoni number for two types of thermal boundary combinations, Type (I) Adiabatic-Adiabatic and Type (II) Adiabatic -Isothermal. The corresponding two thermal Marangoni numbers are obtained and the essence of the different parameters on non-Darcy-Benard double diffusive Marangoni convection are investigated in detail.

냉열원 온도 변화에 따른 다단재열랭킨사이클의 성능해석 (The Performance Analysis of Multi Stage Reheater Organic Rankine Cycle According to Heat Sink Temperature Change)

  • 이호생;임승택;김현주
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.11-17
    • /
    • 2016
  • In this study, the simulation for performance comparison between basic single stage organic rankine cycle, multi stage reheater cycle and multi stage reheater & recuperator cycle was carried out. The multi stage reheater cycle and multi stage reheater & recuperator cycle was designed to improve the efficiency for organic rankine cycle using heat source from industrial waste heat and heat sink from deep ocean water. R245fa was selected as a refrigerant for the cycle and system efficiencies were simulated by the variation of the heat sink temperature and the cycle classification. Performance characteristics were simulated by using the Aspen HYSYS. It was confirmed that the system efficiency was decreased by the increase of heat sink temperature. These results can be considered to be applied as geo-ocean thermal energy conversion in where plenty of geothermal or ocean thermal resource exist.

빌딩 구조체 활용 지열원 열펌프 시스템의 냉난방성능 특성 (Heating and Cooling Performance Characteristics of Ground Source Heat Pump System Utilizing Building Structures as Heat Source and Sink)

  • 김남태;최종민;손병후;백성권;이동철;양희정
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.143.2-143.2
    • /
    • 2011
  • Energy foundations and other thermo-active ground structure, energy wells, energy slab, and pavement heating and cooling represent an innovative technology that contributes to environmental protection and provides substantial long-term cost savings and minimized maintenance. This paper focuses on earth-contact concrete elements that are already required for structural reasons, but which simultaneously work as heat exchangers. Pipes, energy slabs, filled with a heat carrier fluid are installed under conventional structural elements, forming the primary circuit of a geothermal energy system. The natural ground temperature is used as a heat source in winter and heat sink in summer season. The system represented very high heating and cooling performance due to the stability of EWT from energy slab. Maximum heat pump unit COP and system COP were 4.9 and 4.3.

  • PDF

LNG 냉열을 열싱크로 이용하는 유기랭킨사이클(ORC)의 작동유체에 따른 성능 특성 (Effects of Working Fluids on the Performance Characteristics of Organic Rankine Cycle (ORC) Using LNG Cold Energy as Heat Sink)

  • 김경훈;하종만;김경천
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.200-208
    • /
    • 2014
  • This paper presents thermodynamic performance analysis of organic Rankine cycle (ORC) using low temperature heat source in the form of sensible energy and using liquefied natural gas (LNG) as heat sink to recover the cryogenic energy of LNG. LNG is able to condense the working fluid at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the mathematical model, a parametric analysis is conducted to examine the effects of eight different working fluids, the turbine inlet pressure and the condensation temperature on the system performance. The results indicate that the thermodynamic performance of ORC such as net work production or thermal efficiency can be significantly improved by the LNG cold energy.

겉보기 열원 및 습기 흡원의 세 재분석 자료 비교와 몬순 지역별 분석 (Three Reanalysis Data Comparison and Monsoon Regional Analysis of Apparent Heat Source and Moisture Sink)

  • 하경자;김서경;오효은;문수연
    • 대기
    • /
    • 제28권4호
    • /
    • pp.415-425
    • /
    • 2018
  • The roles of atmospheric heating formation and distribution on the global circulation are of utmost importance, and those are directly related to not only spatial but also temporal characteristics of monsoon system. In this study, before we clarify the characteristics of apparent heat source <$Q_1$> and moisture sink <$Q_2$>, comparisons of three reanalysis datasets (NCEP2, ERA-Interim, and JRA-55) in its global or regional patterns are performed to clearly evaluate differences among datasets. Considering inter-hemispheric difference of global monsoon regions, seasonal means of June-July-August and December-January-February, which is summer (winter) and winter (summer) in the Northern (Southern) Hemisphere are employed respectively. Here we show the characteristics of eight different regional monsoon regions and find contributions of <$Q_2$> to <$Q_1$> for the regional monsoon regions. Each term in apparent heat source and moisture sink is shown to come from the ERA-Interim dataset, since the ERA-Interim could be representative of three datasets. The NCEP2 data has a different characteristic in the ratio of <$Q_2$> and <$Q_1$> because it overestimates <$Q_1$> compared to the other two different datasets. The Australia monsoon has been performing better over time, while some regional monsoons (South America, North America, and North Africa) have been showing increasing data inconsistency. In addition, the three reanalysis datasets are getting different marching with time, in particular since the early 2000s over South America, North America, and North Africa monsoon regions. The recent inconsistency among the three datasets that may be associated with the global warming hiatus remains unexplored.