• Title/Summary/Keyword: heat of hydration in concrete

Search Result 538, Processing Time 0.022 seconds

Thermal heat reduction of concrete using LHT (수화열 저감제를 이용한 콘크리트 수화열 저감법 개발)

  • Lee, Sang-Ho;Kim, Yong-Ro;Jung, Yang-Hee;Kim, Do-Su
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.701-704
    • /
    • 2006
  • Recently, the attention is paid to the problem of thermal crack by hydration heat according to the increase of high strength and mass concrete structures. At this point, various research has been carried out for the control of hydration heat in high strength and mass concrete. As a part of the research, the application of Low Heat Technology (LHT) for the control of thermal crack by hydration heat was investigated in this study. To investigate the application, it was selected LHT which can reduce hydration heat of concrete with effect in series I and II. Also, it was investigated the characteristics of hydration heat generation of low heat concrete using LHT with binder types in seriesIII.

  • PDF

A Study on the Control of Hydration Heat of Mass Concrete Using Super Retarding Agent (초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구)

  • 유동수;심보길;윤치환;한민철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.515-520
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

A Study on the Control of Hydration Heat of Mass Control Using Super Retarding Agent (초지연제를 이용한 매스콘크리트의 수화열 조정에 관한 연구)

  • 유동수;심보길;윤치환;한민철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.469-474
    • /
    • 2001
  • Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

Investigation on the Applicability for Method of Setting Time Difference by Super Retarding Agent for Reducing Hydration Heat of Transfer Girder Mass Concrete (전이보 매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 적용가능성에 대한 검토)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.128-131
    • /
    • 2004
  • This paper is to investigate the mock up test results of mass concrete for transfer girder using setting time difference with super retarding agent(SRA) to reduce hydration heat. According to test results, the temperature history of plain concrete without placing lift had a steep rising curvature, and plain concrete had a big temperature difference between surface and middle section of mass concrete, which may result in occurrence of temperature crack. However, considering placing method B, because setting time of middle section concrete was retarded with an increase in SRA contents, higher hydration heat temperature was observed at surface section concrete compared with that at middle section concrete at early age, which can lower the possibility of hydration heat crack. In case of placing method C, although peak temperature of hydration heat was much lower, at early age, high crack occurrence possibility of the hydration heat attributable to the big temperature difference between middle section and bottom section of concrete was expected at bottom section concrete. Therefore, the structure above the ground like transfer girder is not applicable to consider the placing method C.

  • PDF

Experimental Study on the Generation of Hydration Heat of Binder using Latent Heat Material (잠열재를 사용한 결합재의 수화발열 특성에 관한 실험적 연구)

  • Kim, Yong-Ro;Kim, Do-Su;Khil, Bae-Su;Kim, Ook-Jong;Lee, Do-Bum
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.3
    • /
    • pp.103-107
    • /
    • 2009
  • It is necessary to develop a new technology for effectively controlling thermal crack caused hydration heat according to the increasing construction of large size massive concrete structures such as mat foundation of high-rise building. Therefore, to develop a new technology for reducing hydration heat of large size massive concrete in this study, it was investigated hydration heat generation properties of binder using latent heat materials. As a test result, it was confirmed that latent heat materials were advanced on the reduction of hydration heat and control of thermal crack. It is expected to be applied as the excellent technology on the management of hydration heat and thermal crack in large size massive concrete structures.

A Parameter Study on Heat of Hydration in Mass Concrete Affected by Foundation Depth and Various Thermal Properties (지반 깊이 및 열특성 영향에 따른 매스콘크리트의 수화열 해석)

  • 채숙희;양성철;박종원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.799-804
    • /
    • 2002
  • This paper is mainly Intended to show an effect of foundation depth on heat of hydration in mass concrete. From the analysis, it was found that the foundation depth which is not affected by the heat conduction is more than 5 m. But this study shows that, an optimum foundation depth for the FEM analysis for heat of hydration in mass concrete is approximately 1 m from this study. And in order to study tile significance of various parameters, a sensitivity analysis of heat transfer in mass concrete is performed and the amount of heat liberated at complete hydration of unit weight of cement and the reaction velocity of hydration are the most sensitive parameters factors of other various parameters.

  • PDF

An Experimental Study on the Hydration Heat Control of Mass Concrete Using Heat Pipe (히트파이프를 이용한 매스콘크리트의 수화열 제어에 관한 실험 연구)

  • BaeK, Dong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.6
    • /
    • pp.81-86
    • /
    • 2007
  • In order to eliminate the hydration heat of mass concrete, this paper reports the results of hydration heat control in mass concrete using the OCHP (Oscillating capillary tube heat pipe). In the summarized results of the mock up experiments, distributing the heat pipe at 300 mm intervals based on the center of the test specimen was the most effective. A 200 mm turn interval for the heat pipe was measured to be the most appropriate, taking into account the reinforcement placing at the actual site. Therefore, when the hydration heat control method using the heat pipe developed in this study is applied, not only canconstruction efficiency & a reduction in the necessary construction time be expected, but so can outstanding economical effects.

An Experimental Study on the Evaluation of Hydration Heat of Low Heat Concrete (in case of Belite rich Cement) (저발열 콘크리트 수화열 평가의 실험적 연구 (Belite rich 시멘트 중심))

  • 현석훈;박춘근;신영인;김용호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.352-357
    • /
    • 1996
  • In hardening massive concrete, the heat of hydation gives rise to considerable thermal gradientsand thermal stresses, which might cause early age cracking. This paper deals with the results of evaluation of hydration heat of low hear concrete, using Belite rich cement (low heat cement) and compared with OPC, slag added cement and fly ash addedcement. Result of evaluation of hydration are presented in this paper. The concrete made with Belite rich cement gets low temperature of center point and low thermal gradients between surface and center points.

  • PDF

Dispersion Effect of Hydration Heat in Mass Concrete Using Embedded Heat Pipe (매입형 히트파이프를 이용한 매스콘크리트 수화열 분산 효과)

  • Kim, Myung-Sik;Youm, Chi-Sun;Baek, Dong-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.85-90
    • /
    • 2009
  • Although most of existing hydration heat control methods show a certain degree of hydration heat control, generally, there are many problems as mentioned above. Therefore, our laboratory previously developed a hydration heat control method using an exposed heat pipe, which solves most of these problems and simultaneously displays excellent hydration heat control. Unfortunately, even this method had some problems such as the processing, transport, and assembly of heat pipes, and the surface treatment of a cut plane after pouring, and hardening concrete. Therefore, in this study, a hydration heat control method using an embedded pipe has been developed with the expectation that this method solves those problems in hydration heat control using an exposed heat pipe. As a result of the experiment, the peak temperature of ECHP and ICHP specimen about $4.5{\sim}6.5^{\circ}C$ than the OPC specimen and the probability of thermal cracked generated in ECHP and ICHP specimen decreased up to $13{\sim}20%$. Finally, it was confirmed in this study that the hydration heat control method using an embedded heat pipe is significantly more superior and cost effective than the existing method of an exposed one.

A Study on the characteristics of hydration heat evolution of several types of cement (각종 시멘트의 수화발열 특성에 관한 연구)

  • 정연식;노재호;한정호;송용순;강석화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.125-130
    • /
    • 1997
  • This study is to investigate properties of relationship between the heat of hydration of several type cements and the temperature of concrete in restraint condition. As the results, the heat of hydration is largely affected by the temperature of cementious materials. However, the heat of hydration of cement and temperature rise of concrete is differently resulted in the content of cement.

  • PDF