• 제목/요약/키워드: heat loss reduction

검색결과 183건 처리시간 0.03초

고출력 슁글드 태양광 모듈의 온도 저감에 따른 출력 특성 분석 (Analysis of Output Characteristics of High-Power Shingled Photovoltaic Module due to Temperature Reduction)

  • 배재성;유장원;지홍섭;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.439-444
    • /
    • 2020
  • An increase in the temperature of photovoltaic (PV) modules causes reduced power output and shorter lifetime. Because of these characteristics, demands for the heat dissipation of PV modules are increasing. In this study, we attached a heat dissipation sheet to the back sheet of a shingled PV module and observed the temperature changes. The PV shingled module was tested under Standard Test Conditions (STCs; irradiance: 1,000 W/㎡, temperature: 25℃, air mass: 1.5) using a solar radiation tester, wherein the temperature of the PV module was measured by irradiating light for a certain duration. As a result, the temperature of the PV module with the heat dissipation sheet decreased by 3℃ compared to that without a heat dissipation sheet. This indicated that the power loss was caused by a temperature increase of the PV module. In addition, it was confirmed that the primary parameter contributing to the reduced PV module output power was the open circuit voltage (Voc).

개별난방과 지역난방방식의 에너지절감 및 환경개선효과 분석 (Assessment for the effect of heating systems on the energy consumption and environment)

  • 임용훈;김혁주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.466-473
    • /
    • 2007
  • The comparison for the performance of heating systems, district heating and separate heating and power, is carried out in terms of energy consumption and environment on the basis of real operating data. The efficiency of boiler and the heat loss within the housing are assumed with reasonable manner due to the lack of reliable data regarding those quantities. The assessment for the established criteria of previous studies is performed and the new criteria for the analysis is proposed. It is shown that the district heating system is superior to the separate heating and power system from the point of view of reduction of energy use and environment improvement. The sensitivity study for those quantities with uncertainty such as the boiler efficiency and heat loss within the housing is carried out also and the reasons for the analysis results are discussed in detail.

  • PDF

지열을 이용한 공조외기부하저감(空調外氣負荷低減)시스템의 설계 및 도입 효과에 관한 연구 -실측결과 및 열성능 예측을 위한 수치모델의 제안- (Study on Designing and Installation Effect of Fresh Air Load Reduction by using Underground Double Floor Space-Experimental Result and Proposal of Numerical Model for Thermal Performance-)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제7권3호
    • /
    • pp.233-240
    • /
    • 2004
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space The system was introduced into a real building and was examined by the field measurement Judging from the measurements during three years(1999~2001), the state of the system operation was very stable through this period and it was clear that the system contributes to reduction of energy consumption for air-conditioning. Futhermore, a simulation model used the simple heat diffusion equation Was developed to simulate its thermal characteristics and performances The simulations resulted m air temperature in good agreement with the measurements. Also, from the result of numerical analysis, It is clear that the amount of heat supply by using this system is more than the amount of energy loss to the room above it. Therefore, it is concluded that this systems is very useful and the proposed numerical model can be used for the prediction of system thermal performance.

  • PDF

금속 DPF를 이용한 입자상물질의 저감효율에 관한 연구 (PM Reduction Efficiency using Metal Type DPF)

  • 나완용
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.176-180
    • /
    • 2013
  • After-treatment apparatus ceramic DPF (diesel particulate filter) have been applied to reduce harmful particulate matters(PM) among emissions from diesel engines so far, but they are easy to be fragile and weak in thermal shock. This research aims to investigate a metal type filter which is superior in mechanical strength and heat conduction rate and is beneficial economically in manufacturing. Basic performance of metal DPF such asloading test, temperature gradient test, thermal shock test, heat resistant test and back pressure was carried out. And then their experimental data provided key informations in designing and manufacturing such as detailed structures of metal mesh filter. Also diesel engine and vehicle of 2957cc displacement was tested under lug-down 3 mode and CVS-75 mode. PM reduction efficiency was 54.5% using metal DPF without loss of performance and fuel consumption.

가솔린 엔진에서의 냉각수로의 전열량에 대한 연구 (A Study on the Heat Rejection to Coolant in a Gasoline Engine)

  • 류택용;신승용;이은현;최재권
    • 한국자동차공학회논문집
    • /
    • 제5권6호
    • /
    • pp.77-88
    • /
    • 1997
  • The heat rejection to coolant is a dominant factor for building vehicle cooling system such as radiator and cooling fan. Since the vehicle cooling system also has effects on fuel consumption and noise, the study of heat rejection to coolant has been emphasized. However, the study on heat rejection to coolant has been mainly focused on the field that related to the characteristics of combustion and localized heat loss. It is no much of use in design for the entire cooling system because it is focused on such a specific point. In this work, the heat rejection rate to coolant for four different engines are obtained to derive a simple heat transfer empirical formula that can be applied to the engine cooling system design, and it is compared with the other studies. Also, to observe effects of engine operation factors and heat transfer factors on coolant, we measured the metal temperature and the heat rejection rate. The heat rejection to coolant does not depend significantly upon the coolant flowrate, but mainly upon the amount of air fuel mixture and the air fuel ratio as long as the composition of coolant does not change. The reduction of heat rejection to coolant did not effectively improve the fuel consumption, but was mostly converted to raise the exhaust gas temperature and the oil temperature.

  • PDF

Effects of a mild heat treatment on mouse testicular gene expression and sperm quality

  • Zhao, Jun;Zhang, Ying;Hao, Linlin;Wang, Jia;Zhang, Jiabao;Liu, Songcai;Ren, Bingzhong
    • Animal cells and systems
    • /
    • 제14권4호
    • /
    • pp.267-274
    • /
    • 2010
  • The decrease in sperm quality under heat stress causes a great loss in animal husbandry production. In order to reveal the mechanism underlying the sperm quality decrease caused by heat stress, we first established a mild heat-treated mouse model. Then, the sperm quality was identified. Further, the testicular proteome profile was mapped and compared with the control using 2D electrophoresis and mass spectrometry. Finally, the differential expressed proteins involved in the heat stress response were identified by real-time PCR and Western blotting. The results showed that heat stress caused a significant reduction in mouse sperm quality (P<0.05). Further, 52 protein spots on the 2D gel were found to differ between the heat-shocked tissues and the control. Of these spots, some repair proteins which might provide some explanation for the influence on sperm quality were found. We then focused on Bag-1, Hsp40, Hsp60 and Hsp70, which were found to be differently expressed after heat shock (P<0.05). Further analysis in this heat-shocked model suggests numerous potential mechanisms for heat shock-induced spermatogenic disorders.

Effect of Heat Treatment on the Dimensional Stability and the Bending Properties of Radiata Pine Sapwood

  • Yun, Ki-Eon;Kim, Gyu-Hyeok;Kim, Jae-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권4호
    • /
    • pp.30-37
    • /
    • 1999
  • The effects of heat treatment on the dimensional stability and bending properties of radiata pine sapwood were investigated. The dimensional stability was almost achieved by heat treatment though the loss of strength was accompanied as a negative effect. The improvement in dimensional stability of wood and the resultant reduction in bending properties were closely related to treatment temperature and duration. The optimum treatment conditions, which could be used to achieve a desired improvement in dimensional stability with resultant losses in modulus of rupture were proposed based on the results obtained in this study.

  • PDF

정사각 덕트 내에서 열/물질전달 촉진을 위한 경사진 단락 요철의 좁은 틈새 효과 (Heat/Mass Transfer Augmentation in a Square Duct . Roughened with Angled Discrete Ribs Having Narrow Gaps)

  • 우성제;이세영;최청;조형희
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.150-158
    • /
    • 2002
  • Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the ;augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90° and 60° are selected with e/D$\_$h/=0.08. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. Consequently, the angled discrete ribs with the small gaps provide a more uniform heat/mass transfer distribution sustaining high average heat/mass transfer.

Study on volume reduction of radioactive perlite thermal insulation waste by heat treatment with potassium carbonate

  • Chou, Yi-Sin;Singh, Bhupendra;Chen, Yong-Song;Yen, Shi-Chern
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.220-225
    • /
    • 2022
  • Perlite is one of the major constituents of the radioactive thermal insulation waste (RTIW) originating from nuclear power plants and, for proper waste management, a significant reduction in its volume is required prior to disposal. In this work, the volume reduction of perlite is studied by high-temperature treatment method with using K2CO3 as a flux. The perlite is ground with 0-30 wt% K2CO3, and differential thermal analysis/thermogravimetric analysis is used to monitor the glass transition temperature (Tg) and weight loss. The Tg varied between ~772.2 and 837.1 ℃ with the minima at ~643.5 ℃ with the addition of ~10 wt% K2CO3. It is observed that compared to the pure perlite the volume reduction ratio (VRR) increases with the addition of K2CO3. The VRR of 11.20 is observed with 5 wt% K2CO3 at 700 ℃, as compared to VRR of 5.56 without K2CO3 at 700 ℃. The X-ray photoelectron spectroscopy and scanning electron microscopy are used to characterize perlite samples heat-treated without/with 5 wt% K2CO3 at 700 ℃. Moreover, the atomic absorption spectroscopy indicates that the proposed heat-treatment procedure is able to completely retain the radionuclides present in the perlite RTIW.

난연처리된 목재의 연소속도에 관한 연구 (A Study on the Burning Rate of Fire Retardant Treated Wood)

  • 박형주
    • 한국안전학회지
    • /
    • 제22권6호
    • /
    • pp.46-54
    • /
    • 2007
  • The purpose of this study was to examines the burning rate of fire retardant treated wood in the cone heater with a one-dimensional integral model. The wood samples used in this study were four species. The species of woods are Redwood, White oak, Douglas fir and Maple. Each sample was nominally 50mm thick and 100mm square. Samples were exposed to a range of incident heat fluxes 10 to $35kW/m^2$ using the cone heater. A one-dimension integral model has been used to predict burning rate, heat of gasification, flame heat fluxes, charring rate and char depth of samples. As a result measurement of mass loss rate, softwoods(Redwood and Douglas fir) has relatively low value than those for hardwoods(White oak and Maple). Average charring rate of woods in case of fire retardant treatment showed reduction effect of 41.29%, 50.00%, 48.18% and 60.82% for Redwood, Douglas fir, White fir and Maple, respectively. Almost all the predictions from integral model showed faster charring than those measured. Average difference between predictions and experimental data was 16%, 9.5% and 11.8% for N, F1 and F2 respectively. Water-soluble fire retardant used in this study find out more effect in hardwood than softwood from the result of measurement of mass loss rate and average charring rate.