• Title/Summary/Keyword: heat leakage

Search Result 341, Processing Time 0.024 seconds

A Study on the Tube/tubesheet Interface in the Heat Exchangers Jointed by Explosive Bonding (폭발접합된 열교환기류 튜브와 튜브시트의 계면 특성에 관한 고찰)

  • 이병일;공창식;이상철
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.38-47
    • /
    • 2000
  • Characteristics of the interface between tube and tube sheet which were formed by explosive expansion and roll expansion, have been studied in the research. The results are as follows: Optimum amounts of explosives for the expansion of Alloy 600 (19.05mm and 15.88mm) were found to be RDX 3.5-8.5g/m. Because explosive expansion caused les strain hardening and increased bounding strength, characteristics of the explosively expanded were better than those of mechanically expanded. As the transition region of the explosive expansion is inactive, the resistance to the stress corrosion cracking increases by 30∼40% compared to the roll and hydraulic expansion.

  • PDF

Numerical Study of Film Cooling Characteristics in Turbine Blade Cavity (터빈 블레이드 캐버티 내 막냉각 특성에 관한 수치해석적 연구)

  • Kim, Kyung-Seok;Cho, Hyung-Hee;Kang, Shin-Hyoung
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.648-651
    • /
    • 2008
  • Numerical calculations are performed to simulate the film cooling effect of turbine blade tip with squealer rim. Because of high temperature of inside rim, squealer rim is damaged easily. Therefore many various cooling systems were used. The calculations are based on 100,000 Reynolds number in linear cascade model. A blade has 2% tip clearance and 8.4% rim height. The axial chord length and turning angle is 237mm, 126$^{\circ}$. Numerical calculations are performed without and with film cooling. In a film cooling in the cavity, hot spots of cavity were cooled effectively. However hot spots of suction side rim still remains. The CFD results show that the circulation flow in cavity of squealer tip affects the temperature rise of squealer rim. To maintain the blade integrity and avoid the excessive hot spot of blade, rearrangement of cooling hole is needed.

  • PDF

Cross Sectional Thermal and Electric Potential Imaging of an Operating MOSFET (작동중인 모스 전계 효과 트랜지스터 단면에서의 상대온도 및 전위 분포 측정)

  • Kwon, Oh-Myoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.7
    • /
    • pp.829-836
    • /
    • 2003
  • Understanding of heat generation in semiconductor devices is important in the thermal management of integrated circuits and in the analysis of the device physics. Scanning thermal microscope was used to measure the temperature and the electric potential distribution on the cross-section of an operating metal-oxide-semiconductor field-effect transistor (MOSFET). The temperature distributions were measured both in DC and AC modes in order to take account of the leakage current. The measurement results showed that as the drain bias was increased the hot spot moved to the drain. The density of the iso-potential lines near the drain increased with the increase in the drain bias.

Integrity Assessment of Weld Repair of Bolt-Screw Assembly (볼트-나사 결합체의 보수용접 건전성 평가)

  • Kim, Maan-Won;Shin, In-Hwan;Lee, Kyoung-Soo
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.79-86
    • /
    • 2015
  • The purpose of this study is to evaluate structural integrity of a weldment which is partially screwed and then welded. Two finite element models are constructed and solved: operating temperature and internal pressure are considered in the first simple model, and welding process and normal operating condition including heat-up process are simulated in the second model. Structural integrity assessment criteria are satisfied with both finite element models, therefore the repair weldment finely sustains structural integrity of this assembly and prevents leakage. Stresses are dramatically increased when weld residual stress is considered, but it should be considered as a secondary stress.

Failure Analysis of Austenitic Stainless Steel Pipe (오스테나이트계 스테인레스 강관에서의 손상해석에 관한 연구)

  • 이상율;이종오;이주석;조경식;조종춘;이보영
    • Journal of Welding and Joining
    • /
    • v.11 no.1
    • /
    • pp.21-32
    • /
    • 1993
  • A cracking failure of a austenitic stainless steel elbow in a naphtha cracking line in a petrochenmical plant occurred, resulting in leakage of organic compound flowing inside the elbow. Due to the failure, emergency shutdown of the plant was enforced to repair the troubled part of the line. The repair cost as well as production loss during the unscheduled plant shutdown has cost the company a great amount of financial loss. In this studies, a failure analysis of the cracked elbow was performed using NDT, chemical analysis, microstructural analysis including optical microscopy as well as scanning electron microscopy with EPMA, mechanical testings such as tensile testing, hardness testing and Charphy impact test fractography. The results indicated that several problems such as a welding defect and presence of a detrimental phase which was found to be relate to improper postforming heat treatment process was identified and the failure was concluded to be due to a low temperature embrittlement of the defect-containing elbows.

  • PDF

Manufacturing Technique of Suspension Insulator far Distribution Lines Using Composite materials (배전급 고분자 현수애자의 제조기술 개발)

  • 홍진영;김영성;지응서;김영찬;백주흠;김동욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.306-310
    • /
    • 1996
  • In this paper a series of developing process for an insulator which can be employed in overhead distribution lines, using polymeric composite materials, is introduced. In order to design an insulator for heavily polluted area, weathershed of alternating type was adopted, which could have longer leakage distance. Modified EVA was used as surface material which has good electrical and mechanical characteristics as well as superior chemical stability. FRP core was covered with above surface material through heat shrinking process. By standardization of each process, higher productivity and lower production cost could be ensured. The developed insulator has been put under various tests including long-term field test and artificial aging test and satisfactory results were obtained.

  • PDF

Assessment Technique and Aging Test for EHV Porcelain Insulators (송전용 자기재 애자의 열화시험 평가기술)

  • Han, S.W.;Cho, H.G.;Park, K.H.;Jung, G.C.;Lee, D.I.;Choi, I.H.;Shin, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.480-483
    • /
    • 2002
  • This paper through shift norm of insulator and research by accident prevention countermeasure special skill authoritativeness verification of insulator and Long Term aging factor for power transmission analysis and evaluate and prove quality of insulator wish to. Assessment technique by aging of own porcelain insulator observes ageing factor for reciprocity comparison through several examinations. Through cool and heat accelerated Aging test, can measure the leakage current change amount that ensue to each Cycle. Can confirm own blazing fire factor as distribution freshness that ensue in HRB Test's hardness value.

  • PDF

Electrical Properties of ${Ba_{0.5}}{Sr_{0.5}}{TiO_3}$Thin Film with Various Heat Treatment Conditions (다양한 열처리 조건에 따른 ${Ba_{0.5}}{Sr_{0.5}}{TiO_3}$박막의 전기적 특성)

  • 손영국
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.492-498
    • /
    • 2001
  • Ba$_{0.5}$Sr$_{0.5}$TiO$_3$타겟을 이용 Pt/Ti/SiO/Si 기판 위에 R.F magnetron sputtering 방법으로 BST 박막을 증착하여 다양한 열처리 조건에 따른 BST 박막의 전기적 성질(정전용량, 누설전류)에 대해 박막의 결정성과 미세구조의 연관성에 대하여 연구하였다. BST 박막의 유전상수는 grain size에 영향 받으며, 열처리 온도가 증가할수록 유전상수는 증가함을 보였고 온도에 따른 누설전류는 저전압 영역에서는 Hopping conduction, 고전압 영역에서는 Schottky conduction mechanism을 따르는 것으로 나타났다.

  • PDF

A Study on Initiating Events Identification of the IS Process

  • Cho, Nam-Chul;Jae, Moo-Sung;Eon, Yang-Joon
    • International Journal of Safety
    • /
    • v.5 no.1
    • /
    • pp.29-32
    • /
    • 2006
  • There has been an increasing need for substitute energy development due to the dry up of the fossil fuel and environmental problems. Among the substitute energy under consideration, producing hydrogen from water without the accompanying release of carbon has become a promising technology. Also, Iodine-Sulfur (IS) thermochemical water decomposition is one of the promising processes that can produce hydrogen efficiently using the high temperature gas-cooled reactor (HTGR) as an energy source capable of supplying heat at over 1000. In this study, to effect an initiating events identification of the IS process, Master Logic Diagram (MLD) was used and 9 initiating events that cause a leakage of the chemical material were identified.

10kVA High $T_c$ Superconducting Power Transformer with Double Pancake Winding (더블펜케익 권선형 10kVA 고온초전도 변압기)

  • Lee, H.J.;Cha, G.S.;Lee, J.K.;Choi, K.D.;Ryu, K.W.;Hahn, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.934-936
    • /
    • 2000
  • This paper presents the design of a double pancake winding type high $T_c$ superconducting power transformer In the design of the transformer. BSCCO-2223 tape was considered as the conductor. Double pan cake winding was adopted in order to easy the construction of the winding and to lessen the leakage reactance of the transformer. Numerical calculation was used to decide the arrangement of the double pan cake winding. Room temperature bore type cryostat has been constructed and its heat loss was estimation.

  • PDF