해가림의 이랑방향이 인삼의 생육에 미치는 영향을 구명하고자 방위각
These studies were carried out (1) to investigate the growth characteristics of Sedum album L. in the field, (2) to propose a suitable shallow peen roof system for this plant, and (3) to evaluate plant growth in the proposed system over the long term. The growth characteristics, such as morphological properties, growth habit, shade tolerance, and flowering, were surveyed. In experimental shallow green-roof systems, the effects of drainage type, substrate type, and soil depth on plant growth were investigated. Then drought tolerance was investigated. After planting Sedum album L. in the proposed system survival rate, cover, and resistance to insects, heal and cold were evaluated for about 2 years. The results of these studies are summarized below. 1. In the field, the aboveground part of Sedum album L. did not die back during the winter. Plant height was 4
토양수분함량이 묘삼의 생육특성 및 수량에 미치는 영향을 구명하기 위해 비가림 시설하우스에서 토양수분을
This study aims to develop protective pants to relieve impact from falls and to present basic data for the development. The survey results are as follows; First, 45% of the respondents were in their 60s and 55% of them were in their over 70s and older. Also, 64% of them have fallen once for the past year and 36% of them have fallen twice or more. The older they were, the more there were those who have fallen twice or more. This indicated the older people has experienced more fall accidents again after a initial fall accident. Second, as per accident situations, the survey showed that fall accidents happened the most in the winter and in the afternoon (12-18 pm). Also, it happened on a street mostly and they were wearing sneakers or hiking boots when they got a hurt slipped in a front or side by missing their step in a walk. The injury areas are mostly knee and ankle. They had the bruises or a sprain in their knee and ankle mostly. The rate of bone fracture was 19.5%. Therefore, the protection area to falls in lower body is the knee. But hip and hip joint should be protected with knee as well because those are usually be broken when it is damaged. Third, approximately 80% of those who were hospitalized for treatment had surgery. Patients who had surgery were rather in their over 70s than in their 60s. The older they were, the more serious their fracture was. The period of hospital or outpatient treatment is more than three weeks in many cases. They responded their health got worse after falls. Aftereffects of accidents were physical discomfort, anxiety and medical costs. Falls to the old makes physical damage, psychological damage, which cause reduced physical activity and the increased cost of health care with economic losses. So it results on a negative impact on the life of the old. Fourth, elderly females were rarely aware of impact protective clothing and they have never purchased such clothing. For impact protective pants, the major consideration was suitable design for their body types. They liked casual style with front or side pockets and simple designs without any patterns or decorations. As per pants materials, they responded that they need functionality, activity and elasticity. Among the functional points, insulation of cloths are considered importantly, so the heat reservance of material in the impact protective pants should be considered carefully.
through a literal study upon Arrhythmia between east and west medicine, the results were as follows 1. Arrhythmia is not only irregular cardiac beat but disorder of cardiac impulse making and conduction disturbance. it means almost irregularity of interval between two beat 2. In the east medicine, arrhythmia is represented various category as palpitation, continuous palpitation, dizziness, consumption which give the first consideration by the accompanied symptoms. A separate way in a diagnostics it become a base of diagnosis of diseases and decision of prognosis by the examination of pulse 3. In the west medicine, Arrhythmia is classified as disorder of heart rate, rhythm, conduction disturbance or tachycardia, bradycardia and it is concomitant with fatigue, palpitation, dyspnoea, syncope, chest discomfort 4. The diagnostic study of pulse condition which represent arrhythmia was started from
지구온난화에 따른 북한지역의 식량작물 생산을 주축으로 하는 이모작의 특성을 평가하기 위해서 온난화의 지역적 특성, 겨울작물의 월동온도, 여름작물의 냉해유발온도 및 이모작 작부양식별 소요적산온도 확보 등 온열지표의 변화를 농업기후지대별로 검토한 결과는 다음과 같다. 1. 온난화의 지역적 특성 북한의 온난화는 과거(1973-1994)보다 최근(2002-2006) 들어 연간 평균기온
Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.
동물성(動物性) 지방섭취량(脂肪攝取量)의 증가(增加), 운동부족(運動不足), 비만(肥滿), 스트레스의 가중(加重), 고령화(高齡化)의 증가(增加) 등(等)의 원인(原因)으로 순환기계질환(循環器系疾患)의 발병률(發病率)이 증가(增加)하고 있으며, 이러한 순환기계질환(循環器系疾患)의 위험인자(危險因子)로서 혈전증(血栓症)이 중요(重要)하게 대두되고 있다. 특히 최근 문제시되고 있는 협심증(狹心症)이나 심근경새(心筋梗塞)등의 허혈성(虛血性) 심질환(心疾患)은 혈소판응집(血小板凝集)에 의해 일어나는 혈전형성(血栓形成)에 기인(起因)하고 있다. 한의학(韓醫學)에서 혈전증(血栓症)은 어혈(瘀血)의 범주(範疇)에 속(屬)하며, 어혈(瘀血)은 각종 병리적(病理的) 원인(原因)에 의해 발생한 전신성(全身性) 또는 국소성(局所性)의 혈액순환(血液循環) 장애(障碍) 또는 혈류정체(血流停滯)와 그에 수반되는 일련의 증후(症候)를 나타내며, 경계정충, 고창(鼓脹), 적취(積聚), 미하, 전광(癲狂), 중풍등(中風等)의 발병원인(發病原因)이 된다. 또한 어혈(瘀血)에 의한 각종 증후(症候)에는 활혈거어제(活血祛瘀劑) 또는 구어혈제(驅瘀血劑)등이 사용되고 있다. 본(本) 연구(硏究)에서는 한의학(韓醫學)에서 어혈증(瘀血症)으로 야기(惹起)되는 여러 가지 증상(症狀)의 개선에 사용되는 구어혈제(驅瘀血劑)들의 혈소판응집(血小板凝集)에 미치는 영향을 검색하기 위하여 계지복령환(Geijibokryunghwan; GBH) 및 그 구성약물(構成藥物)을 사용(使用)하였다. 계지복령환은 "금궤요략" 에 있는 방(方)으로써 거사부상정(祛邪不傷正)하고 조기한열(調氣寒熱)하여 예로부터 구어혈제(驅瘀血劑)로 사용되어 왔다. 이에 계지복령환 및 그 구성약제(構成藥劑)의 ADP, AA 또는 collagen으로 유도되는 혈소판응집(血小板凝集)에 대하여 억제효과(抑制效果)를 탐색(探索)한 결과(結果), 계지복령환 및 개별(個別) 구성약물(構成藥物)의 혈소판응집억제작용(血小板凝集抑制作用)을 확인하였고, 혈소판응집(血小板凝集)으로 야기(惹起)되는 혈전증(血栓症)등에 계지복령환 및 개별(個別) 구성약물(構成藥物)은 매우 임상실험적(臨床實驗的) 응용가치(應用價値)가 있는 것으로 생각되었다.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70