• 제목/요약/키워드: heat flux

검색결과 2,360건 처리시간 0.03초

비정상열유속 기법을 이용한 표면 열유속 해석에 관한 연구 (A Study on the Analysis of Surface Heat Flux Using the Transient Heat Flux Method)

  • 이종주
    • 한국군사과학기술학회지
    • /
    • 제13권3호
    • /
    • pp.503-510
    • /
    • 2010
  • The quick variation of the canister wall temperature causes the modification of the shape of canister wall. This paper is the possibility of adoption and the error analysis about the transient heat flux method. The commercial code(Fluent Ver6.2.16) was employed for the calculation of surface temperature in the case of steady and unsteady heat flux condition. Based the surface temperature variation and surface material property, transient heat flux method can calculate the surface heat flux. In the case of steady heat flux condition, the error is about 2%, and in the case of unsteady heat flux condition, the error is about 3.6%. With the unsteady heat flux condition, the time which reach the maximum surface heat flux is almost same between the numerical analysis and transient heat flux method.

기상 조건에 따른 도시 캐노피 모형의 성능 비교 (Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions)

  • 유영희;백종진;이상현
    • 대기
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

An Experimental Study of Critical Heat Flux in Non-uniformly Heated Vertical Annulus under Low Flow Conditions

  • Chun, Se-Young;Moon, Sang-Ki;Baek, Won-Pil;Chung, Moon-Ki;Masanori Aritomi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권8호
    • /
    • pp.1171-1184
    • /
    • 2003
  • An experimental study on critical heat flux (CHF) has been performed in an internally heated vertical annulus with non-uniform heating. The CHF data for the chopped cosine heat flux have been compared with those for uniform heat flux obtained from the previous study of the authors, in order to investigate the effect of axial heat flux distribution on CHF. The local CHF with the parameters such as mass flux and critical quality shows an irregular behavior. However, the total critical power with mass flux and the average CHF with critical quality are represented by a unique curve without the irregularity. The effect of the heat flux distribution on CHF is large at low pressure conditions but becomes rapidly smaller as the pressure increases. The relationship between the critical quality and the boiling length is represented by a single curve, independent of the axial heat flux distribution. For non-uniform axial heat flux distribution, the prediction results from Doerffer et al.'s and Bowling's CHF correlations have considerably large errors, compared to the prediction for uniform heat flux distribution.

강재 급속냉각용 고온 열유속게이지 개발 (Development of High-Temperature Heat Flux Gauge for Steel Quenching)

  • 이정호
    • 열처리공학회지
    • /
    • 제23권6호
    • /
    • pp.323-330
    • /
    • 2010
  • The present study was motivated by increasing demands on quantitative measurements of the heat flux through the water cooling and quenching process of hot steel. The local heat flux measurements are employed by a novel experimental technique that has a function of high-temperature heat flux gauge in which test block assemblies are directly used to measure the heat flux variation during water cooling and quenching of hot steel. The heat flux can be directly achieved by Fourier's law and is also compared with numerical estimation which is solved by inverse heat conduction problem (IHCP). The high-temperature heat flux gauge developed in this study can be applicable to measure cooling rate and history during the actual cooling applications of steelmaking process. In addition, the measurement uncertainty of heat flux is calculated by a quantitative uncertainty analysis which is based on the ANSI/ASME PTC 19.1-2005 standard.

화염으로부터의 복사 열유속의 계측 I (A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter-)

  • 정종수;인종수;김승수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

ACCURATE ESTIMATION OF GLOBAL LATENT HEAT FLUX USING MULTI-SATELLITE DATA

  • Tomita Hiroyuki;Kubota Masahisa
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.14-17
    • /
    • 2005
  • Global latent heat flux data sets are crucial for many studies such as those related to air-sea interaction and climate variation. Currently, various global latent heat flux data sets are constructed using satellite data. Japanese Ocean Flux data sets with Use of Remote sensing Observations (J-OFURO) includes one of the satellite-derived global latent heat flux data (Kubota et aI., 2000). In this study, we review future development of J-OFURO global latent heat flux data set. In particular, we investigate usage of multi-satellite data for estimating accurate global latent heat flux. Accurate estimation of surface wind speeds over the global ocean is one of key factors for the improved estimation of global latent heat flux. First, we demonstrate improvement of daily wind speed estimation using multi-satellites data from microwave radiometers and scatterometers such as DMSP/SSMI, ERS/AMI, QuikSCAT/SeaWinds, AqualAMSR-E, ADEOS2/AMSR etc. Next, we demonstrate improvement of global latent heat flux estimation using the wind speed data derived from multi-satellite data.

  • PDF

화재실험시 열유속 센서 사용의 단점을 보완한 Heat Flux Mapping Procedure에 관한 연구 (A Study of a Heat Flux Mapping Procedure to Overcome the Limitation of Heat Flux Gauges in Fire Tests)

  • 최금란
    • 한국안전학회지
    • /
    • 제20권4호
    • /
    • pp.171-179
    • /
    • 2005
  • 건물의 마감재료가 화재에 노출될 때 그 마감재료의 역할을 이해하는 것은 필수적이다. 실물화재실험을 통해서 재료의 성능을 평가하는 것이 가능하다. 그러나 실물화재 실험 시 소요되는 시간과 높은 비용으로 인해 실물 화재 실험이 수행되는 경우는 드물고 대신 컴퓨터 화재 시뮬레이션이 개발되어 왔다. 컴퓨터 화재 시뮬레이션에서는 초기입력 데이터로서 점화 버너의 화염으로부터의 Heat Flux Map이 요구된다. 현재까지의 연구에서는 열전대 혹은 열유속 센서와 같은 실험장치의 제한으로 인해 $10kW/m^2$간격의 Heat Flux Map이 나와있을 뿐이고 공간적으로 더 상세한 Heat Flux Map은 없는 실정이다. 화재 시뮬레이션의 성능을 증가시키기 위해서는 점화 버너로부터의 정확하고 상세한 Heat Flux Map이 필요불가결하다. 본 연구의 목적은 적외선 카메라로부터 얻어진 표면온도를 이용하여 벽에서 점화 버너 화염에 대한 Heat Flux Happing Procedure를 개발하는 것이다. 높은 수준의 공간적 해상도는 적외선 카메라로부터 제공된다. 개발된 Heat Flux Mapping Procedure를 증명하기 위해서 ISO 9705 점화버너를 이용해서 실험이 행해졌다. 실험 결과를 통해 개발된 Heat Flux Mapping방법의 열유속 해상도와 공간적 해상도가 얻어졌다. 또한 그 실험 결과가 현재 쓰여지고 있는 Heat Flux Map과 비교되었다.

제주도 북부해역의 표면 열수지 해석 -1993년과 1994년 하계의 경우- (Surface Heat Budget of the Northern Sea of Cheju Island for June-August 1993 and 1994)

  • 김해동;양성기
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.197-206
    • /
    • 1995
  • Surface heat balance of the northern sea of Cheju Island for summer in 1993 and 1994 is analyzed using the observation data obtained by Marine Research Institute, Cheju National University. Each flux elements at the sea surface is derived from the marine meteorological reports with application of an aerodynamical bulk method for the turbulent heat fluxes, and empirical formulae for the long-wave radiation heat fluxes. The flux divergence of oceanic heat transport and the rate of heat storage in the ocean are estimated as residual. The features of the surface heat balance are mainly decided by the solar radiation flux and the latent heat flux for 199B. But the Bowen Ratios were large for 1993. This means that the sensible heat fluxes were nearly equal to the latent heat fluxes for 1993. In this period, mean flux divergence of oceanic heat transport is about 130 W/$m^2$.

  • PDF

Measurement of Heat Flux in Rocket Combustors Using Plug-Type Heat Flux Gauges

  • Kim, Min Seok;Yu, I Sang;Kim, Wan Chan;Shin, Dong Hae;Ko, Young Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권4호
    • /
    • pp.788-796
    • /
    • 2017
  • This paper proposes a new measurement method to improve the shortcomings of an existing integral method for measuring heat flux in plug-type heat flux gauges in the high-temperature and high-pressure environments of liquid-rocket combustors. Using the existing integral measurement method, the calculation of the surface area for the heat flux in the gauge exhibits error in relation to the actual surface area. To solve this problem, transient profiles obtained from ANSYS Fluent were used to calculate unsteady heat flux as it adjusted to the measured temperature. First, a heat flux gauge was designed and manufactured specifically for use in the high-temperature and high-pressure conditions that are similar to those of liquid rocket combustors. A calibration test was performed to prove the reliability of the manufactured gauge. Then, a combustion experiment was conducted, in which the gauge was used to measure unsteady heat flux in a liquid rocket combustor that used kerosene and liquid oxygen as propellants. Reasonable heat flux values were obtained using the gauge. Therefore, the proposed measurement method is considered to offer significant improvement over the existing integral method.

강재 열처리용 다점 열유속 측정 기술 개발 (Development of Multi-point Heat Flux Measurement for Steel Quenching)

  • 이정호;오동욱;도규형;김태훈
    • 열처리공학회지
    • /
    • 제25권4호
    • /
    • pp.181-189
    • /
    • 2012
  • The demand on quantitative measurement of the heat flux is motivated in making higher-quality steel product through a water quenching process of plate mill. To improve a spatial degree of heat flux measurement, the multi-point heat flux measurement was carried out by a unique experimental technique that has a combination of the existing single-point heat flux gauge. The corresponding heat flux can be easily determined by Fourier's law in a conventional way. The multi-point heat flux gauge developed in this study can be applicable to measure the surface heat flux, the surface heat transfer coefficient during a water quenching applications of steelmaking process. The results exhibit different heat transfer regimes; such as single-phase forced convection, nucleate boiling, and film boiling, that are occurred in close proximity on the multi-point heat flux gauge quenched by water impinging jet.