• 제목/요약/키워드: heat equation

검색결과 1,383건 처리시간 0.029초

터널층류방식 청정실에서의 난류운동과 열전달에 관한 수치해석(1) (Numerical Ananlysis on the Tubulent Flow and Heat Transfer in the Tunnel Laminar Flow Type Clean Room(1))

  • 정한식;정효민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.27-33
    • /
    • 1995
  • The turbulent flow and heat transfer in the tunnel laminar flow type clean room is investigated by a numerical simulation. The model clean room is assumed to be a rectngular $5m\times3m$, in which a worktable of 0.75m hight, and 1.5m or 3m long at the floor. Major parameters are the inlet flow velocity, inlet hole size and worktable surface distance. The mean Nusselt number is increased by increasing Reynolds number and can be expressed by the correlation equation.

  • PDF

굴곡의 표면을 가진 금속의 레이저 용융에 대한 열 및 유체유동 해석 (An Analysis of Heat and Fluid Flow in the Laser Surface Melting with a Deformed Surface.)

  • 김영득;심복철;김우승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.139-144
    • /
    • 2003
  • Laser melting problems with deformed substrates are investigated by axisymmetric numerical simulations. Source-based method is used to solve the energy equation, and the momentum equations are solved in the liquid domain with SIMPLER algorithm. Using a laser beam with a top-hat heat flux distribution, this study is performed to examine the effect of surface deformation, beam power density and surface tension force on the melt pool during laser melting. Surface temperature decreases with increasing surface deformation, while surface velocity increases. It is found that surface deformation, beam power density and surface tension force have a very significant effect on heat transfer and fluid flow during laser melting.

  • PDF

ACSR-OC 전선의 단시간 특성 평가 (Assessment of Short-Time Characteristic ACSR-OC Conductor)

  • 이중관;김동명;이수묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1446-1448
    • /
    • 2002
  • The short-time permissible temperature of an overhead distribution line conductor is determined by the softening characteristics of ACSR-OC, ACSR AW/OC 160, typical conductors employed in the overhead distribution line. Transient heat transfer equation and Newton's cooling law were applied to analyze the heating and cooling effects of the insulating conductors, respectively, and the error of co-relation was calibrated after simulating the softening test to assess the short-time characteristic of the insulating conductor. In order to verify the softening characteristic, the conductors were tested with heat cycle. The test was totally carried out 200 cycles, and 1 cycle was to heat and cool at 1.1 times permissible current of the conductor, 1.15 times for 120 minutes, respectively. After heating, the tensile strength and surface of the conductor were observed. In case of ACSR-OC, as the result of 100 hour heating test, the tensile strength of the insulator was 0.8 times the initial value. This is equivalent to the value of the conductors which are used for 10 years at sites.

  • PDF

유한요소법을 이용한 탄소강의 경화능해석(II) (Analysis of Hardenability for Carbon Steel using Finite Element Method(II))

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제3권3호
    • /
    • pp.76-82
    • /
    • 1999
  • This study presents a methodology to predict the hardenability of quenched carbon steels. The equation of transient heat conduction is analyzed to formulate a cooling curve by a finite element method which incorperates coupled effects of temperature on physical properties, the metallic structures and also the latent heat by phase transformation. The volume traction of martensite and pearlite are the structural analysis for hardenability analysis. In order to demonstrate the feasibility of adopting a full quench model respectively. This procedure could be used as the database for optimal condition of heat treatment processes.

  • PDF

Contour Integral Method for Crack Detection

  • Kim, Woo-Jae;Kim, No-Nyu;Yang, Seung-Yong
    • 비파괴검사학회지
    • /
    • 제31권6호
    • /
    • pp.665-670
    • /
    • 2011
  • In this paper, a new approach to detect surface cracks from a noisy thermal image in the infrared thermography is presented using an holomorphic characteristic of temperature field in a thin plate under steady-state thermal condition. The holomorphic function for 2-D heat flow field in the plate was derived from Cauchy Riemann conditions to define a contour integral that varies according to the existence and strength of a singularity in the domain of integration. The contour integral at each point of thermal image eliminated the temperature variation due to heat conduction and suppressed the noise, so that its image emphasized and highlighted the singularity such as crack. This feature of holomorphic function was also investigated numerically using a simple thermal field in the thin plate satisfying the Laplace equation. The simulation results showed that the integral image selected and detected the crack embedded artificially in the plate very well in a noisy environment.

플라즈마 화학 증착에서 증착압력에 따른 TiN 박막의 성장거동 (The Study on the Behavior of TiN Thin Film Growth According to Deposition Pressure in PECVD Process)

  • 이종훈;남옥현;이인우;김문일
    • 열처리공학회지
    • /
    • 제5권2호
    • /
    • pp.95-102
    • /
    • 1992
  • In this study, we tried to describe the quantitative model of TiN film structure which was deposited by PECVD process. The macro-grain growth behavior was studied at the various deposition pressures and times. As a result, It was confirmed that TiN films had the typical Zone 1 structure, and macro-columnar grains were, without reference to the deposition pressure, grown ballistic type by the growth-death competition following the equation, $Y=aX^2$, approximately obtained by regression analysis. Also, the thickness and the crystallization of TiN thin films were increased, the chlorine contents were decreased according to the decreasing of deposition pressure.

  • PDF

Induction Heating Jar의 온도분포 해석에 관한 연구 (A Study on the Temperature-Diffusion Analysis of Induction Heating Jar)

  • 이상호;오홍석;이봉섭;이영미
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 초전도 자성체
    • /
    • pp.79-82
    • /
    • 2002
  • Induction heating is widely used in today's industry, in operations such as metal hardening, preheating for forging operations, melting or cooking. In this paper, it was presented the magneto-thermal analysis of an induction heating jar(IH-JAR) with the material value of the stainless and the aluminum for efficient design. The magnetic field intensity inside the axisymmetric shaped cooker was analyzed using three-dimensional axisymmetric finite element method(FEM) and the effectual heat source was obtained by ohmic losses from eddy currents induced in the jar. The heat was calculated using the heat source and heating equation. Also, it was represented the temperature characteristics of the IH-JAR according to time and relative permeability in stainless parts and in aluminum parts.

  • PDF

저온열원 활용을 위한 유기랭킨사이클의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Organic Rankine Cycles for Use of Low-Temperature Heat Source)

  • 진재영;김경훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.191-194
    • /
    • 2011
  • Low-grade waste heat has generally been discarded in industry due to lack of efficient recovery methods. In recent years, organic Rankine cycle(ORC) has become a field of intense research and appears as a promising technology for conversion of heat into useful work of electricity. In this work thermodynamic performance of ORC with superheating of vapor is comparatively assessed for various working fluids. Special attention is paid to the effects of system parameters such as the evaporating temperature on the characteristics of the system such as maximum possible work extraction from the given source, volumetric flow rate per 1 kW of net work and quality of the working fluid at turbine exit as well as thermal efficiency.

  • PDF

철도터널 화재 시 구난역 내의 연기거동에 대한 수치해석 연구 (Numerical Investigation on Smoke Behavior in Rescue Station for Tunnel Fires)

  • 홍사훈;유홍선;이성혁
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1740-1746
    • /
    • 2008
  • The present study performed numerical investigation to analyze the smoke behavior in the rescue station by using the commercial CFD code (FLUENT Ver 6.3). The present study adopted a 10MW ultrafast mode for simulation, and it also used the MVHS(Modify Volumetric Heat Source) model modified from the original VHS(Volumetric Heat Source) model in order to treat the product generation and the oxygen consumption under the stoichiometric state. In addition, the present simulation includes the species conservation equation for the materialization of heat source and the estimation of smoke movement. From the results, the smoke flows are moving along the ceiling because of thermal buoyancy force and as time goes, the smoke gradually moves downward at the vicinity of the entrance. Moreover, without using ventilation, it is found that the smoke flows no longer spread across the cross-passages because the pressure in the non-accident tunnel is higher than that in the accident tunnel.

  • PDF

회전형(回轉型) 축열식(蓄熱式) 열교환기(熱交換器)에서의 온도효율(溫度效率)에 관한 연구(硏究) (A Study on the Temperature Effectiveness of the Rotary Type Regenerative Heat Exchanger)

  • 김광수
    • 설비공학논문집
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 1989
  • This paper treats the temperature effectiveness of the two-fluid counterflow regenerator in a rotary type. To avoid continual interpolation and to obtain the simple result in calculating that, it obtained the particular solution for the direct-transfer-type counterflow heat exchanger by the graphical procedures. Also, it introduced the empirical formula for the influence of the ratio of rotor matrix to minimum working fluid heat capacity rate with the particular solution induced. Particularly, substituting the published results of temperature effectiveness into the program, it obtained the simple and convenient equation which can applicate in the counterflow regenerator in a rotary type. To compare and discuss the results induced, selecting the regenerative air preheater and applying the their running datum and specifications to the related results, it shows that the above results are agree with the published results within absolute relative error, 3.0%.

  • PDF