• 제목/요약/키워드: heat Index

검색결과 860건 처리시간 0.029초

옥상녹화 조성에 따른 열환경 변화분석 (An Analysis of Thermal Environment Change according to Green Roof System)

  • 박지영;정응호;김대욱;차재규;시미즈 아키
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.100-103
    • /
    • 2009
  • The impermeable area on the surface of city has been increased as buildings and artificial landcover have continually been increased. Urban development has gradually decreased the green zone in downtown and alienated the city from the natural environment on outskirt area devastating the natural eco system. There arise the environmental problems peculiar to city including urban heat island phenomenon, urban flood, air pollution and urban desertification. As one of urban plans to solve such problems, green roof system is attracting attentions. The purpose of this study was to investigate the heat reduction effect according to the development of green roof system and to quantify the heat reduction effect by analyzing through simulation the heat environment before and after green roof system. For thermal environment analysis, Thermo-Render 3.0 was used that was developed by Tokyo Industrial College to simulate. The simulation showed that the heat island index before and after the development of tree-planting on rooftop changed maximum $0.86^{\circ}C$ and the surface temperature changed about $20^{\circ}C$. Only with lawn planting, heat reduction effect was great and it means that the green roof system in low-management-light-weight type is enough to see effect. The simulation identified that only lawn planting for green rooftop brought such difference and could lower the heat island index at a narrow area. It is judged that application of green roof system to wider areas might relieve urban heat island phenomenon positively.

  • PDF

가뭄감시를 위한 파머가뭄지수 개선 방안 연구: 잠재증발산량 산정 방법을 중심으로 (A study on PDSI improvement for drought monitoring: focused on the estimation method of potential evapotranspiration)

  • 문장원;강재원;조영현
    • 한국수자원학회논문집
    • /
    • 제50권12호
    • /
    • pp.863-875
    • /
    • 2017
  • 본 연구에서는 SC-PDSI를 이용하여 잠재증발산량 산정 방법이 가뭄지수 산정 결과에 미치는 영향을 평가하였다. 잠재증발산량 산정 방법으로 월열지수법, Penman-Monteith 방법, Hargreaves 공식 등 세 가지 방법을 이용하였으며, 기상청 56개 지점을 대상으로 세 가지 잠재증발산량 산정 방법에 따른 SC-PDSI를 산정하고 그 결과를 비교하였다. 분석 결과, Penman-Monteith 방법에 의한 결과와 Hargreaves 공식에 의한 결과는 월별로 큰 차이 없이 유사한 가뭄지수 산정 결과를 나타내고 있음을 확인하였으며, 월열지수법에 의한 결과는 상대적으로 큰 차이를 보이고 있음을 알 수 있었다. 월별로는 봄철과 겨울철 기간에 대해 산정된 가뭄지수와 가뭄상황 판단 결과가 차이를 보이고 있음을 확인하였다. 결론적으로 우리나라에서 PDSI를 산정하고자 할 경우에는 Penman-Monteith 방법이나 Hargreaves 공식을 이용하는 것이 바람직할 것으로 판단된다.

셀룰로오스계 파일직물의 탄화가공 (A Study on the Burn-out Printing of Cellulose-blend Velvet)

  • 김호정
    • 한국의류학회지
    • /
    • 제23권5호
    • /
    • pp.757-763
    • /
    • 1999
  • The burn-out technique is used to result in the velvet cloth being patterned in open and solid areas by carbonize the cellulose fiber. It is examined how to burn out the cellulose part of the velvet without damage of the other part. The print paste indalca solution is mixed with sodium hydrogensulfate and lycerine and then screen-printed on the back side of the velvet. The effects of process conditions such as concentration of sodium hydrogensulfate dry heat fixation temperature and time pull no. and glycerine contents on the properties of ground farics were investigated. The yellowness index and the breaking load of silk ground fabrics afected by the process conditions especially concentration of sodium hydrogensulfate dry heat fixation temperature.

  • PDF

용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구 (A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head)

  • 이병곤;태순호
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

건물의 열성능 평가 지표에 관한 연구 (A Study of Thermal Performance Evaluation Index for Building)

  • 김미현;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.67-75
    • /
    • 2007
  • This study intends to the adequacy inspection of the room temperature variation rate that is available in the building heat performance evaluation index, so we performed the sensitivity analysis about the room temperature variation rate and the energy consumption in the room. For these purpose, we supposed the models which are composed of the various window area, insulation thickness and ventilation rate. Then we analyzed the simulation using the ESP-r and Seoul weather data. In this research, the pattern of the increasing & decreasing rate of annual load according to the change of the various design factors is similar to the pattern of increasing & decreasing rate of not the K-values but the room temperature variation rate. Also we derive the optimum value of the various design factors and the room temperature variation rate in this analysis model. Further study is to be required the development of convenient tool to use in the real design.

항균처리를 한 공조기기의 항균성능 평가방법과 평가결과

  • 미우라쿠니오;다까츠까다케시;야나기우;야마자키쇼지
    • 공기청정기술
    • /
    • 제22권2호
    • /
    • pp.40-49
    • /
    • 2009
  • Aluminum thin plate coated with epoxy resin containing about 20wt% brass powder, was applied to fins of heat exchanger. We carried out a series of detailed examinations to evaluate the anti-bacterial performance of the plate and heat exchanger (fan coil unit). In the presence of water or moisture, copper ions which have an anti-bacterial ability eluted from brass powder and showed sufficient effects on many kinds of bacteria. We also evaluated the anti-bacterial performance quantitatively by use of the index API (Anti-bacterial Performance Index) which has already been proposed by authors.

  • PDF

내부 열교환기를 이용한 R744용 초임계 냉동사이클의 성능 분석 (Performance Analysis of R744 (Carbon Dioxide) Transcritical Refrigeration System Using Internal Heat Exchanger)

  • 손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.459-465
    • /
    • 2009
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system. These internal heat exchangers(liquid-suction or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as gas cooler pressure and evaporation temperatures, superheat in the evaporator and temperature of gas cooler outlet, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R744, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative capacity index) of this system. With a thorough grasp of these effect, it is necessary to design the R744 compression refrigeration cycle using internal heat exchanger.

취반기의 가열 방식별 취반미의 특성 비교 분석 (Quality Comparison of Rice Cooked on Heat Plate, Induction Heat, and Heat Plate with Pressure)

  • 김상숙;정혜영
    • 한국식품영양학회지
    • /
    • 제30권3호
    • /
    • pp.464-472
    • /
    • 2017
  • The qualities of rice cooked on heat plate, induction heat and heat plate with pressure, were investigated. The weight, volume, water soluble index (WSI), hydration by SEM (Scanning Electron Microscope), and gelatinization by DSC (Differential Scanning Calorimetry), as well as the consumer acceptability of cooked rice were analyzed. The weight, volume and WSI of rice cooked on heat plate with pressure were higher than those of rice cooked on heat plate and induction heat. The rice cooked on heat plate with pressure also showed higher degree of hydration and gelatinization, and lower degree of enthalpy of gelatinization than the rice cooked on heat plate and induction heat for 5~15 min. The consumer acceptability revealed that the odor, appearance, taste, texture and overall acceptance of rice cooked on induction heat were better than those of rice cooked on heat plate and heat plate with pressure. During storage in a cooker for 0~12 h, there was a decrease in the consumer acceptability of cooked rice. Overall results indicate that the qualities of rice cooked on induction heat and heat plate with pressure were higher than those of rice cooked on heat plate.

인공위성영상과 딥러닝을 이용한 건설공사현장 폭염취약지역 분석 (Heatwave Vulnerability Analysis of Construction Sites Using Satellite Imagery Data and Deep Learning)

  • 김슬기;박승희
    • 대한토목학회논문집
    • /
    • 제42권2호
    • /
    • pp.263-272
    • /
    • 2022
  • 폭염과 도시열섬현상은 기후변화가 진행됨에 따라 피해가 더욱 커지고 있으며, 2050년까지 폭염 발생빈도는 2~6배가 증가될 것으로 예측된다. 특히, 폭염기간동안 건설공사현장에서의 근로자가 느끼는 더위체감지수는 매우 높으며, 도시열섬현상까지 고려하게 되면 체감지수는 더욱 높아진다. 열에 취약한 건설현장 환경과 건설근로자의 상황은 나아지지 않고 있으며, 피해를 줄이기 위해서는 효과적인 대응이 필요한 시점이다. 본 연구에서는 인공위성영상 이미지와 Land Surface Temperature (LST)와 Long Short Term Memory (LSTM) 딥러닝 모델 기법을 적용하여 33℃ 이상 온도가 되는 지역을 분석하고, 폭염에 취약한 건설공사현장을 식별하여 폭염 및 도시열섬현상의 복합적인 피해를 가중시킬 수 있는 가장 취약한 지역을 예측하여 도출하였다. 예측 결과를 통해 건설근로자의 안전을 보장하고, 건설현장 경보시스템의 기반이 될 수 있기를 기대한다.

나노유체의 수직유동 속에 놓인 가는 열선주위의 대류열전달계수 측정 (Measuring Convective Heat Transfer Coefficient Around a Heated Fine Wire in Cross Flow of Nanofluids)

  • 이신표
    • 대한기계학회논문집B
    • /
    • 제32권2호
    • /
    • pp.117-124
    • /
    • 2008
  • Recent researches on nanofluids have mainly focused on the increase of thermal conductivity of nanofluids under static condition. The ultimate goal of using nanofluids, however, is to enhance the heat transfer performance under fluid flow. So it has been highly necessary to devise a simple and accurate measuring apparatus which effectively compares the heat transfer capability between the base and nanofluids. Though the convective heat transfer coefficient is not the complete index for the heat transfer capability, it might be one of useful indications of heat transfer enhancement. In this article, the working principles of experimental system for convective heat transfer coefficient around a heated fine wire in cross flow of nanofluids and its application example to three samples of nano lubrication oils are explained in detail.