• Title/Summary/Keyword: heat Index

Search Result 860, Processing Time 0.032 seconds

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Ecological Studies on the Burned Forest - On the Germination of Remained Seed on Burned Area - (산화적지(山火跡地)의 생태학적(生態學的) 연구(硏究) - 산화후(山火後)의 잔여종자(殘餘種子) 발아율(發芽率)에 대(對)하여 -)

  • Kim, Ok Kyung
    • Journal of Korean Society of Forest Science
    • /
    • v.10 no.1
    • /
    • pp.29-39
    • /
    • 1970
  • Forest fires often destory forests that have taken years to grow in a few minutes. Forest fire therefore, is an important problem in forest management and have caused heavy losses to the nations economy. In order to resolve this problem many investigations have been made in many countries. However, ecological studies on the forest after accidental fire have not yet been made in Korea. In order to conduct such a study, a burned area on Mt. Samak which is located at Dukduwon-ri, Seo-myon, Chunsung-gun, Kangwon-do, was chosen as experimental plot in 1967. The remaining seeds were collected from the burned area, and investigations on their germination rate and their productivity were made comparing to those of the seeds of undemaged area, and following results were obtained. 1. The number of seed collected from the control plots were 740 while it was 537 from the test plots (Table 3, 4). It was considered that this difference between burned and unburned area was mainly due to the fact that some of the seeds had been burnt by the fire, and the unfavorable environmental conditions in the burned area was also considered to be a reason. In the germination rate in the control plots showed 28.1% while it was 3.2% in the test plots. This difference was considered to be due to complete loss of viability of the seed by burning and high heat. 2. In the test plots, sixteen seeds of the Alnus japonica were collected and six of these seeds germinated (index number 100) which was the highest germination rate among the species of collected seeds. From these results, it was considered that a high temperature (above $150^{\circ}C$) caused reduction of the germination rate (Quadrat. 1.2). Seeds of Carex lanceolata var. Nana, were appeared much more in the higher plots than in the lower plots and it seemed to be due to the fact that the forest floor plants were much more abundant in the lower plots than in the higher plots which is covered with shrubbery. And some small seeds midght be able to avoid the effect of fire being burried in the soil or under the gravel. 3. With Pinus densiflora, 43 seeds were collected, and 11 of these germinated in the control plots. However in the test plots, 11 seeds were collected and no seed germinated. This shows that the Pinus densiflora was the weakest in resisting to heat among the observed species in this study. 4. Without exception the germination rate showed a higher index in the herbs than in the woody plants and it is believed that the herbs produced more seed than the wood plants because of the abundance of herbs colony.

  • PDF

Estimation of Potential Evapotranspiration using LAI (LAI를 고려한 잠재증발산량 추정)

  • Kim, Joo-Hun;Kim, Kyung-Tak
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.1-13
    • /
    • 2005
  • In the process of a hydrology circulation, evapotranspiration is considered a very important factor to build a plan for the development of water resources and to operate water resources system. This study purposes to estimate daily potential evapotranspiration quantity in consideration of energy factors of the surface by using spatial information such as Landsat TM (ETM+) data, DEM and Landcover. Kyounan-cheon, Han River is selected as a target area, and landcover is divided by vegetation and non-vegetation covered area. Penman-Monteith equation which considers leaf-area index is used to estimate potential evapotranspiration quantity of vegetation covered area. The combination method (energy burget and aerodynamic method) is used in non-vegetation covered area. Among the input data for estimating potential evapotranspiration, NDVI, SR and Albedo is formed by Landsat, TM and ETM+ from 1986 through 2002. ground heat flux is estimated by using NDVI distribution map, LAI distribution map is drawn by using SR distribution map. The result of estimation shows that the average potential evapotranspiration in the whole basin is about 1.8-3.2mm/day per each cell. THe results of estimating potential evapotranspiration quantity by each landcover are as follows; water surface 3.6-4.9mm/day, city 1.4-3.1mm/day, bareland 1.4-3.5mm/day, grassland 1.7-3.7mm/day, forest 1.7-3.0mm/day and farmland 1.8-3.6mm/day. The potential evapotranspiration quantity is underestimated in comparison with observed evaporation data by evaporation pan, but it is considered that it has physical propriety.

  • PDF

A fundamental study on the development of feasibility assessment system for utility tunnel by urban patterns (도심지 유형별 공동구 설치 타당성 평가시스템 개발에 관한 기초 연구)

  • Lee, Seong-Won;Sim, Young-Jong;Na, Gwi-Tae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.1
    • /
    • pp.11-27
    • /
    • 2017
  • The road network system of major domestic urban areas such as city of Seoul was rapidly developed and regionally expanded. In addition, many kinds of life-lines such as electrical cables, telephone cables, water&sewerage lines, heat&cold conduits and gas lines were needed in order for urban residents to live comfortably. Therefore, most of the life-lines were individually buried in underground and individually managed. The utility tunnel is defined as the urban planning facilities for commonly installing life-lines in the National Land Planning Act. Expectation effectiveness of urban utility tunnels is reducing repeated excavation of roads, improvement of urban landscape; road pavement durability; driving performance and traffic flow. It can also be expected that ensuring disaster safety for earthquakes and sinkholes, smart-grind and electric vehicle supply, rapid response to changes in future living environment and etc. Therefore, necessity of urban utility tunnels has recently increased. However, all of the constructed utility tunnels are cut-and-cover tunnels domestically, which is included in development of new-town areas. Since urban areas can not accommodate all buried life-lines, it is necessary to study the feasibility assessment system for utility tunnel by urban patterns and capacity optimization for urban utility tunnels. In this study, we break away from the new-town utility tunnels and suggest a quantitative assessment model based on the evaluation index for urban areas. In addition, we also develop a program that can implement a quantitative evaluation system by subdividing the feasibility assessment system of urban patterns. Ultimately, this study can contribute to be activated the urban utility tunnel.

Studies on Cure Kinetics and Thermal Stability of Epoxy/Nylon 6 Blend (에폭시/나일론6 블랜드의 경화 동력학 및 열안정성에 관한 연구)

  • Kim, Dong-Kyu;Kim, Kwan-Woo;Han, Woong;Kwac, Lee-Ku;Kim, Byung-Joo
    • Applied Chemistry for Engineering
    • /
    • v.26 no.5
    • /
    • pp.538-542
    • /
    • 2015
  • In this work, effects of the blend composition composed of 0, 10, 20, 30 and 40 wt% of nylon 6 to epoxy (diglycidylether of bisphenol-A, DGEBA) resin were investigated in terms of cure kinetics and thermal stability by differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA). As the content of the nylon 6 increased, the maximum exothermic temperature ($T_{max}$) and the value of cure activation energy ($E_a$) decreased. The maximum exothermic temperature of the blending samples decreased with increasing in nylon 6 content, resulting in the decrease in curing activation energy of them due to the rapid curing reaction with epoxy resin in this system. From TGA analysis results of the DGEBA/nylon 6, the thermal stability based on the thermal stability index ($A^*{\cdot}K^*$) and integral procedure decomposition temperature (IPDT) increased with increase in the nylon 6 content. This was because of the combination of DGEBA and nylon 6 having good heat resistance, resulting in improving thermal stability of the DGEBA/nylon 6.

Estimation of Water Temperature by Heat Balance Method in Paddy Field. (열수지법(熱收支法)에 의한 벼논의 수온추정(水溫推定))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Im, Jung-Nam;Takami, Shinich
    • Korean Journal of Environmental Agriculture
    • /
    • v.8 no.1
    • /
    • pp.30-36
    • /
    • 1989
  • To determine irrigated water temperature under the rice plant canopy, micrometeorological elements air temperature, relative humidity, water temperature, solar radiation, and the rice leaf area index the rice plant canopywere measured. Water temperature under the canopy was also estimated from these data. The results are as follows ; 1. Maximum and minimum temperatures of water in the paddy field were higher about $1-2^{\circ}C$ than those of air temperature. 2. Mean water temperature under the canopy became lower than mean air temperature when the leaf area indices were greater than 4, because of decreased light penetration rates 3. Penetration amounts of net radiation under the canopy can be estimated by an exponential equation 4. Estimated water temperatures under the canopy by a combination method model was adaptable in Suweon, a plain area, but its accuracy was lower in Jinbu, an alpine area.

  • PDF

The Health and Nutritional Status of Middle Aged Men at Worksite in Taejon (대전지역 직장 중년 남성의 건강 및 영양 상태 조사)

  • 우미경;김성애
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.3
    • /
    • pp.338-348
    • /
    • 1997
  • This study was conducted to investigate the health and nutritional status of 123 middle aged men at their worksite in Taejon. The results of this study on the factors that influence their health and nutritional status were as follows : 1) 74.8$\%$ of the subjects had history in the order of alimentary, heat, liver, diabetic and pulmonary diseases. 30.3$\%$ stopped smoking at 42.3% yrs. and 74.5$\%$ smoked more than 10 cigarets per day. Also 71.9$\%$ drank 2-3 times per week and 35.3$\%$ drank 1-2 times per week. 91.4$\%$ exercised more than 30min every day. 2) 54.4% showed concerns about their health whereas 20.3$\%$ were afraid that they night get sick. 3) 90.4$\%$ ate regularly and 54.5$\%$ worried about their cholesterol, salt, fat and MSG intakes. 48.7$\%$ ate out 1-2times per week and their favorite foods eaten outside were Korea. 4) 41.5$\%$ were classified as 'normal A', 30.9$\%$ 'normal B' group and high blood pressure and liber diseases in 'doubtful for disease' group were pointed out from their 1996 health check ups. 5) By Broca index, 39.8$\%$ were overweight and 9.8% were obese however by BMI only 23.6% were overweight. According to the relationship between calculated and self recognized obesity, 62.4$\%$ categorized themselves into the right weight range but 34.3$\%$ thought they were thinner than they were. 6) 43.9$\%$ were border line in cholesterol intake and 12.1$\%$ needed medical care for high blood cholesterol. 7) The Average energy intake was 1970.6㎉(80.9$\%$ RDA) with a 65 :19 : 16 ratio of carbohydrate : protein : fat. Protein, Fe, thiamin, riboflavin, niacin and Vit. A. 8) Occupation, regularity of meals, partner's job, income. smoking, alcohol drinking, health concerns and eating out were the factors that influenced the subject's nutrient intakes and health status. from this study, it was found that middle aged men needs to know their health and nutritional status and to be educated correct health and nutritional information through formal or informal channel. The worksite is the vest place to do this and we want these results to be used to develop the nutrition education program for middle aged men at the worksite.

  • PDF

Estimation of THI Index to Evaluate Thermal Stress of Animal-occupied Zone in a Broiler House Using BES Method (BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Hong, Se-Woon;Choi, Hee-chul;Lee, Jun-yeob;Lee, Dong-hyun;Woo, Saemee;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Lee, In-bok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.2
    • /
    • pp.75-84
    • /
    • 2018
  • Thermal stress of livestock has been issued due to recent climate change trends and this causes reproductive disorders, decreased feed consumption, immunosuppression, and increased mortality of animals. Concept of THI has been widely used to quantitatively evaluate the degree of thermal stress for animals, however use of this concept is restricted for animals living in the enclosed facilities such as mechanically ventilated broiler houses. In this study, time-based internal energy flow and variation trends of temperature and humidity were analyzed based on BES technique. Local weather data, insulation characteristics of building materials, heat and moisture generation rate from broilers according to age, algorithm of ventilation operation were adopted for boundary condition of the model to accurately compute THI values inside the mechanically ventilated broiler house. From the BES computation, excess frequency of THI threshold in Jeju city was highest on the assumption that air conditioning equipments were not installed. When general raising density ($39kg\;m^{-2}$) was adopted, total 2,191 hours were exceeded. Excess hours of THI threshold were strongly related to the cumulative air temperature ($R^2=0.87$).

Uniformity Evaluation of Elderly Hospital Outpatients' Waiting Space using Discrete Event Simulation (이산사건 시뮬레이션을 이용한 요양병원 외래부 대기공간 균일성 평가)

  • Yoon, So-Hee;Kim, Suk-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.490-499
    • /
    • 2017
  • In recent years, the introduction of complex systems analysis based on various variables has become more active in order to identify and analyze complex problems of Modern Society. Prediction of patients' spatial perception and usability according to the spatial arrangement of the outpatient department is a very important factor for providing high quality hospital service. For objective analysis, the standard program procedure and analysis index for the diseases of the elderly were prepared and the uniformity of the atmospheric space was evaluated through heat map analysis and quantitative analysis. In this study, 73 cells were installed and simulated to analyze the uniformity of the four alternatives according to the change of the arrangement of the medical care space, receiving space, and consultation space using the complex system analysis method for the nursing hospitals. The resulting density was derived. The results are as follows. 1)The layout of the reception space has the greatest influence on the total spatial density of the waiting space. 2) The uniformity of the waiting space can be increased by separating the examination space and the examination space. 3)The closer the location of the receiving space is from the entrance, the greater the density of the waiting space. Finally, this study applied discrete event simulation to the evaluation of uniformity of atmosphere space, and proved that the actor - based model can be utilized for utilization and evaluation as spatial analysis methodology.

A Study on Improvement of Fire-resistant and Flame-retardant Properties of Silicone Rubber Composites Containing Perlite (펄라이트를 첨가한 실리콘 고무 복합체의 내화 및 난연 특성 향상에 관한 연구)

  • Lee, Byung-Gab;Lee, Jong-Hyeok;Bang, Dae-Suk;Won, Jong-Pil;Jang, Il-Young;Park, Woo-Young;Jhee, Kwang-Hwan
    • Elastomers and Composites
    • /
    • v.46 no.2
    • /
    • pp.164-170
    • /
    • 2011
  • In this study, silicone rubber filled with environmentally-friendly perlite was prepared by mechanical mixing in order to improve thermal properties, such as heat and fire resistances. We found that the properties of silicone rubber composites depended on perlite concentration by various characterization methods. Thermogravimetric analysis(TGA) indicated that the initial degradation temperature of silicone/perlite composite was higher than that of pristine silicone rubber. The gas torch test showed that the opposite side temperature of composite materials was remarkably low as compared to that of pristine silicone rubber. In addition, the composites containing 5 wt% and 10 wt% of perlite showed remarkable thermal stability at elevated temperatures according to the results of both fireproof furnace tests under the RABT condition and carbonization furnace tests. The images from a scanning electron microscope(SEM) showed the degree of dispersion of perlite in silicone rubber. Finally, it was confirmed that limited oxygen index(LOI) was increased with perlite concentration.