• Title/Summary/Keyword: heat/non-heat treatment

Search Result 518, Processing Time 0.029 seconds

Texture and Formability Development of Non-lubrication Rolled Al Alloy Sheet (무윤활 압연한 알루미늄 합금의 집합조직과 성형성)

  • Akramov, Saidmurod;Kim, In-Soo
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Formability and other mechanical properties of sheet metals are strongly dependent on the texture. It was studied to improve the formability of the Al alloy(AA3003) sheets which were rolled under the non-lubrication condition and subsequent heat treated. In the non-lubrication rolled and subsequent heat treated Al alloy sheet, the variation of the plastic strain ratios were investigated in this study. Non-lubrication rolled Al sheets showed a fine grain size and after subsequent heat treated specimens showed that the $\beta$-fiber texture component was increased. The plastic strain ratios of the non-lubrication rolled and subsequent heat treated Al alloy sheets were about two times higher than those of the original Al sheets. These could be related to the formation of $\beta$-fiber texture components through the non-lubrication rolling and subsequent heat treatment in Al sheet.

The Effect of Nitrogen Plasma Treatment on Tribological Behaviors of Plasma-sprayed Zirconia Coatings

  • Lim, Dae-Soon;Shin, Jong-Han;Lee, Jung-Yeob;Cho, Chang-Hee
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.7
    • /
    • pp.602-607
    • /
    • 2001
  • Zirconia powder containing 3 mol% yttria (3Y-PSZ) was casted on the cast iron substrate by plasma spraying method. Coated specimens were then heat treated at 500$\^{C}$ in nitrogen plasma. Wear tests were performed on nitrogen heat treated and non heat treated samples at temperatures from 25$\^{C}$ to 600$\^{C}$. Wear results showed that the friction coefficient and the wear loss of both the treated and the non-treated samples showed maximum value at 400$\^{C}$. These results were explained by low temperature thermal degradation due to the monoclinic transformation. Nitrogen plasma treatment significantly improved the tribological performance. The effect of nitrogen heat treatment on tribological behavior was explained by the increased micro-hardness and decreased monoclinic faction.

  • PDF

Enhanced Virus Safety of a Solvent/Detergent-Treated Anti-hemophilic Factor IX Concentrate by Dry-Heat Treatment

  • Shin Jeong-Sup;Choi Yong-Woon;Sung Hark-Mo;Ryu Yeon-Woo;Kim In-Seop
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2006
  • With particular regards to the hepatitis A virus (HAV), a terminal dry-heat treatment ($100^{\circ}C$ for 30 min) process, following lyophilization, was developed to improve the virus safety of a solvent/detergent-treated antihemophilic factor IX concentrate. The loss of factor IX activity during dry-heat treatment was of about 3%, as estimated by a clotting assay. No substantial changes were observed in the physical and biochemical characteristics of the dry-heat-treated factor IX compared with those of the factor IX before dry-heat treatment. The dry-heat-treated factor IX was stable for up to 24 months at $4^{\circ}C$, The dry-heat treatment after lyophilization was an effective process for inactivating viruses. The HAV and murine encephalomyocarditis virus (EMCV) were completely inactivated to below detectable levels within 10 min of the dry-heat treatment. Porcine parvovirus (PPV) and bovine herpes virus (BHV) were potentially sensitive to the treatment. The log reduction factors achieved during lyophilization and dry-heat treatment were ${\ge}5.60$ for HAV, ${\ge}6.08$ for EMCV, 2.64 for PPV, and 3.59 for BHV. These results indicate that dry-heat treatment improves the virus safety of factor IX concentrates, without destroying the activity. Moreover, the treatment represents an effective measure for the inactivation of non-lipid enveloped viruses, in particular HAV, which is resistant to solvent/detergent treatment.

Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange (기상응축 열교환을 이용한 고정밀 등온 가열로 개발)

  • Hong, Hyun-Seon;Kong, Man-Seek;Kang, Hwan-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.3
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

The Effect of Differential Heat Treatment on the Mechanical Properties and Microstructure of the Large Back-up Roll (대형Back-Up roll에서 차등열처리가 기계적 성질 및 조직변화에 미치는 영향)

  • Kim, Gyeong-Hyeon;Gang, Seok-Bong;Jeon, Ui-Jin;Jang, Yun-Seok
    • 한국기계연구소 소보
    • /
    • s.16
    • /
    • pp.3-16
    • /
    • 1986
  • The first specimens were sampled across the depth of roll products processed by rapid heating and cooling of the roll, namely, differential heat treatment. The second samples were taken from the non-heat treated roll at different depths. The samples were heat treated following the same temperature history as that at each corresponding location in the roll where the samples were taken. Consequently, both specimens showed the similar microstructure and mechanical properties (tensile, impact and fatigue strength etc.)

  • PDF

Clinical Characteristics and Prognosis of Heat Stroke (열사병의 임상적 특징 및 예후에 관한 연구)

  • Park, Noh Han;Ryoo, Hyun Wook;Seo, Kang Suk;Park, Jung Bae;Chung, Jae Mung
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.113-120
    • /
    • 2006
  • Purpose: The aim of this study was to evaluate the clinical characteristics of classic heat stroke in Korea and to identify factors of prognosis for heat stroke by comparing a survival group with a non-survival group. Methods: We retrospectively analyzed 27 patients with heat stroke who visited the Emergency Department of Kyungpook National University Hospital from March 2001 to February 2005. First, we divided the patients into two groups, the classic heat stroke group and the exertional heat stroke group, and compared them. Second, we compared the survival group with the non-survival group. Age, sex, cause, place where patients were found, underlying diseases, cooling time, performance of endotracheal intubation, initial Glasgow Coma Scale, initial vital sign, and laboratory findings were reviewed. Results: Five of 27 patients in heat stroke died. The classic heat stroke group had 20 patients. They were old and had more patients in the bathroom than the exertional heat stroke group had. The non-survival group showed lower blood pressure, lower initial GCS score, and higher respiratory rate than the survival group. In laboratory findings, the non-survival group also showed lower$HCO_3-$ level, lower albumin level, lower glucose level, more prolonged PT, and higher CK-MB level than the survival group. Delay in recognition of heat stroke and cooling were poor prognostic factors in heat stroke. Conclusion: The classic heat stroke group had patients who were old and found in the bathroom. Early recognition and treatment of heat stroke is important to reduce mortality. Cooling time, initial GCS score, mean arterial pressure, resipratory rate, $HCO_3-$, PT, CK-MB, and albumin seem to be meaningful when forming a prognosis for heat stroke patients.

Study on the Cold Formability of Drawn Non-heat Treated Steels (신선 가공된 열처리 생략강의 냉간 성형성에 대한 연구)

  • 박경수;박용규;이덕락;이종수
    • Transactions of Materials Processing
    • /
    • v.12 no.4
    • /
    • pp.364-369
    • /
    • 2003
  • Non-heat treated steels are attractive in the steel-wire industry since the spheroidization and quenching-tempering treatment are not involved during the processing. However, non-heat treated steels should satisfy high strength and good formability without performing heat treatment. Therefore, it is important to investigate optimum materials showing a good combination of strength and formability after the drawing process. In this study, three different steels such as dual phase steel, low-Si steel, and ultra low carbon bainitic steel were used to study their mechanical properties and the cold formability. The cold formability of three steels was investigated by estimating the deformation resistance and the forming limit. The deformation resistance was estimated by calculating the deformation energy, and the forming limit was evaluated by measuring the critical strain revealing crack initiation at the notch tip of the specimens. The results showed that deformation resistance was the lowest in the low-Si steel, and the forming limit strains of ultra low carbon bainitic steel and low-Si steel were higher than that of commercial SWRCH45F steel.

Microstructural Evolution in CuCrFeNi, CuCrFeNiMn, and CuCrFeNiMnAl High Entropy Alloys

  • Hyun, Jae Ik;Kong, Kyeong Ho;Kim, Kang Cheol;Kim, Won Tae;Kim, Do Hyang
    • Applied Microscopy
    • /
    • v.45 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • In the present study, microstructural evolution in CuCrFeNi, CuCrFeNiMn, and CuCrFeNiMnAl alloys has been investigated. The as-cast CuCrFeNi alloy consists of a single fcc phase with the lattice parameter of 0.358 nm, while the as-cast CuCrFeNiMn alloy consists of (bcc+fcc1+fcc2) phases with lattice parameters of 0.287 nm, 0.366 nm, and 0.361 nm. The heat treatment of the cast CuCrFeNiMn alloy results in the different type of microstructure depending on the heat treatment temperature. At $900^{\circ}C$ a new thermodynamically stable phase appears instead of the bcc solid solution phase, while at $1,000^{\circ}C$, the heat treated microstructure is almost same as that in the as-cast state. The addition of Al in CuCrFeNiMn alloy changes the constituent phases from (fcc1+fcc2+bcc) to (bcc1+bcc2).

Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation (주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험)

  • Kim N.H.;Cho J.P.;Han S.P.;Choi J.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

Effectiveness of herbal ointment Biyeom-go according to cold-heat pattern identification: a subgroup analysis on patients with rhinitis (한열(寒熱) 변증에 따른 한의 외용 치료제 비염고의 치료 효과 : 하위 그룹 분석)

  • Son, Mi-Ju;Lee, Dong-Hyo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.32 no.4
    • /
    • pp.29-40
    • /
    • 2019
  • Objectives : Hwanglyeonhaedok-tang(黃連解毒湯) is a representative herbal formula with "clear heat(淸熱)" effects. The aim of this study was to evaluate the effects of Hwanglyeonhaedok-tang-based intranasal herbal ointment Biyeom-go based on the cold and heat pattern identification questionnaire(CHPIQ). Methods : We performed a subgroup analysis of the previously published prospective observational study. A total of 58 patients with rhinitis were administered Biyeom-go for 4 weeks, and its effects on the Total Nasal Symptom Score(TNSS), Mini Rhinoconjunctivitis Quality of Life Questionnaire(Mini-RQLQ) score, and nasal endoscopy index score were analyzed based on CHPIQ. Results : Among the 58 patients, the heat and non-heat patterns were shown by 39 and 19 patients, respectively, while the cold and non-cold patterns were shown by 46 and 12 patients, respectively. The change in TNSS from baseline negatively correlated with the heat pattern score(p=0.011). Improvement in TNSS was greater in the heat pattern group than in the non-heat pattern group, with a borderline significant difference(p=0.07). Mini-RQLQ and nasal endoscopy index scores tended to be lower in the heat pattern group than in the non-heat pattern group, but without a statistically significant difference. Conclusion : The findings indicate that CHPIQ is a useful tool for the diagnostic and prognostic evaluation of patients with rhinitis. This study provides fundamental evidence of the close association between the cold-heat pattern in patients with rhinitis and the treatment effects of Biyeom-go.