• Title/Summary/Keyword: heart valve replacement

Search Result 365, Processing Time 0.025 seconds

Annual Open Heart Surgery: Report of 416 Cases in 1980 (연간 개심술 416례 보고 [1980 년도])

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1981
  • In 1980, 416 cases of open heart surgery were done in this Department with over all operative mortality of 12.3%. 1. There were 288 congenital anomalies consisting of 174 acyanotic and 114 cyanotic varieties, which showed operative mortality of 6.9% and 25.4% respectively. 2. There were 128 cases of acquired lesions, 124 valvular disease and 3 myxoma being the main lesions. 3. There were 128 cases of valve replacement with operative mortality of 7.8%. 4. The most frequently operated anomaly was VSD, 90 pure VSD and 21 cases were associated with one or 2 cardiac anomalies. Over all operative mortality in 111 VSD cases was 8.1% but in 90 pure VSD cases it was 6.7%. 5. Tetralogy of Fallot showed the highest incidence in cyanotic group with 88 cases, consisting of 68 pure and 20 with other cardiac anomalies. Over all mortality in 88 cases was 19.3% but in pure form 16.2%. 6. In 128 valve replacement cases over all mortality was 9.4%. There were 85 mitral, 11 aortic, 2 tricuspid, 21 mitral with aortic, 6 mitral with tricuspid, 3 mitral, aortic, and tricuspid valve replacement cases. For mitral valve replacement operative mortality was 5.9%. 7. Twenty-one cases of babies under 10kg body weight were operated on with over all operative mortality of 28.6%. Sixteen cases of VSD were found with operative mortality of 25%. 8. Among 128 cases of valve replacement 7 were under the age of 15 years and 12 were between 15 and 20 years old. Five pediatric cases underwent mitral valve replacement without mortality, 9 year old boy was the youngest among them. In this Department open heart surgery for infancy and complex anomalies showed still hip operative risk which should be improved in the coming years. For open heart surgery Shiley oxygenators and 2 sets of A-O de-lux 5 head roller pump were utilized exclusively. For valve replacement Ionescu-Shiley bovine pericardial xenografts were mainly used. In pediatric and rural patients Persantin with aspirin regimen was satisfactorily administered for anticoagulation after valve replacement. Routinely Coumadin was administered for one year after valve replacement* In patients who had thrombus on valve sites, chronic atrial fibrillation, and giant left atrium Persantin-Aspirin regimen was used when one year coumadin administration was discontinued.

  • PDF

Clinical Analysis of Repeated Heart Valve Replacement (심장판막치환술 후 재치환술에 관한 임상연구)

  • Kim, Hyuck;Nam, Seung-Hyuk;Kang, Jeong-Ho;Kim, Young-Hak;Lee, Chul-Burm;Chon, Soon-Ho;Shinn, Sung-Ho;Chung, Won-Sang
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.817-824
    • /
    • 2007
  • Background: There are two choices for heart valve replacement-the use of a tissue valve and the use of a mechanical valve. Using a tissue valve, additional surgery will be problematic due to valve degeneration. If the risk of additional surgery could be reduced, the tissue valve could be more widely used. Therefore, we analyzed the risk factors and mortality of patients undergoing repeated heart valve replacement and primary replacement. Material and Method: We analyzed 25 consecutive patients who underwent repeated heart valve replacement and 158 patients who underwent primary heart valve replacement among 239 patients that underwent heart vale replacement in out hospital from January 1995 to December 2004. Result: There were no differences in age, sex, and preoperative ejection fraction between the repeated valve replacement group of patients and the primary valve replacement group of patients. In the repeated valve replacement group, the previously used artificial valves were 3 mechanical valves and 23 tissue valves. One of these cases had simultaneous replacement of the tricuspid and aortic valve with tissue valves. The mean duration after a previous operation was 92 months for the use of a mechanical valve and 160 months for the use of a tissue valve. The mean cardiopulmonary bypass time and aortic cross clamp time were 152 minutes and 108 minutes, respectively, for the repeated valve replacement group of patients and 130 minutes and 89 minutes, respectively, for the primary valve replacement group of patients. These results were statistically significant. The use of an intra aortic balloon pump (IABP) was required for 2 cases (8%) in the repeated valve replacement group of patients and 6 cases (3.8%) in the primary valve replacement group of patients. An operative death occurred in one case (4%) in the repeated valve replacement group of patients and occurred in nine cases (5.1%) in the primary valve replacement group of patients. Among postoperative complications, the need for mechanical ventilation over 48 hours was different between the two groups. The mean follow up period after surgery was $6.5{\pm}3.2$ years. The 5-year survival of patients in the repeated valve replacement group was 74% and the 5-year survival of patients in the primary valve replacement group was 95%. Conclusion: The risk was slightly increased, but there was little difference in mortality between the repeated and primary heart valve replacement group of patients. Therefore, it is necessary to reconsider the issue of avoiding the use of a tissue valve due to the risk of additional surgery, and it is encouraged to use the tissue valve selectively, which has several advantages over the use of a mechanical valve. In the case of a repeated replacement, however, the mortality rate was high for a patient whose preoperative status was not poor. A proper as sessment of cardiac function and patient status is required after the primary valve replacement. Subsequently, a secondary replacement could then be considered.

Clinical Analysis of Prosthetic Valve Replacement on Acquired Heart Disease (후천성 심질환의 인공판막치환술에 대한 임상적 고찰)

  • Lee, Jun-Yeong;Ji, Haeng-Ok
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.951-959
    • /
    • 1989
  • Between September, 1972 and September, 1989, total 359 patients were operated for acquired heart disease at Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital. A consecutive series of 293 prosthetic valve replacement was also performed during this period. The results were summarized as follows; 1. There were 141 men and 218 women, whose ages ranged from 6 to 64 years, [mean 35.5 years] 2. Out of 293 cases, mitral valve replacement was 182 cases, aortic valve replacement was 39 cases and double valve replacement was70 cases. 3. Early post-operative death was 30 cases [Mortality; 8.4 %] and late death was 9 cases in the survivors. 4. Re-operation was 30 cases and operative mortality was 10%. 5. Mean post-operative interval was 76 months. [Ranged from 216 months to 2 months] 6. Among re-operation cases, primary prosthetic valve failure was 16 cases and paravalvular leakage was 2 cases. 7. Since January 1988, 79 cases of prosthetic valve replacement were performed and then 1 case was expired. [Mortality; 1.2 %]

  • PDF

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF

Cardiac Valve Replacement: A Report of 16 Cases (심장판막 이식에 관한 연구)

  • 김주현;이영균
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.89-100
    • /
    • 1975
  • Sixteen cases of cardiac valve replacements have been done in this department since 1970. Twelve cases of mitral valve replacement were done with Beall valve, 2 cases of aortic valve replacement with Starr-Edwards and Magoven valve and 2 cases of double valve replacement using Beall valve for mitral and Magovern valve for aortic. Three patients [18.8%] died during operation. Two cases [12.5%] of hospital mortality occurred because of congestive heart failure and asphyxia due to tracheomalacia 3 months after operation. Follow-up studies from two to 27 months showed excellent results except three cases of late mortality [18.8 %]. Thromboembolism occurred in two double valve replacement patients[12.5%]who were fatal.

  • PDF

Re-replacement of prosthetic heart valves: report of 7 cases (인공심장판막의 재치환수술: 7례 보)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • Prosthetic valve replacement has resulted in marked improvement in the functional status of many patients with valvular heart disease. But valve failure from various causes has necessitated re-replacement of prosthetic valve in some of these patients. This selective group of patients has many inherent problems. This report presents our experience with seven patients who received re-replacement of prosthetic valve in the Seoul National University Hospital from 1981, to 1983. The patients included one woman and six men in the range of 9 and 49 years old. As the first valve operations, there were five MVR using tissue valves, one DVR [Bjork-Shiley and Ionescu-Shiley valve] and one case of modified Bentall operation with composite graft [Ionescu-Shiley valve]. Reoperations on prosthetic valve failure were performed 17 to 54 months after the first operation [mean 34 months]. Amon8 seven patients, there were two cases of prosthetic valve endocarditis and five cases of primary tissue failure. Gross calcification of the xenograft was found in two children with Ionescu-Shiley valve. All except one had relatively successful operative results. The unsuccessful one died intraoperatively from low output syndrome.

  • PDF

Clinical Experiences of St. Jude Medical Cardiac Valve Replacement (St. Jude Medical valve의 임상적 고찰)

  • 김종원
    • Journal of Chest Surgery
    • /
    • v.25 no.5
    • /
    • pp.518-525
    • /
    • 1992
  • 50 months experience with St-Jude Medical Cardiac Valve Prosthesis The St. Jude Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism. The data for this study was collected from April 1986 to May 1990, four years period. There were total of 110 patients[female 53, male 58] in this series with 22 isolated aortic valve, 66 isolated mitral valve, 20 double valve, 2 tricuspid valve replacement. The mean follow up time was 23 months. Postoperatively, 77% of cases were in New York Heart Association[NYHA] functional class I, and mild and moderate symptoms[NYHA II ] were present in 20% and there were very few patients remaining in higher functional classifications. In postoperative echocardiographic study showed marked improved cardiac function. The overall early mortality was 5.4% and was higher after double[13.3%] and mitral valve replacement[5.6%] and the late mortality was one case after mitral valve replacement due to endocarditis. The cause of death in early mortality was attributed to heart failure, acute renal failure, sepsis, etc.

  • PDF

Reoperation of Prosthetic Heart Valve; An Analysis of Operative Risks and Late Results (인공 심장판막의 재치환술 -수술 위험인자와 수술 결과의 분석-)

  • 김관민
    • Journal of Chest Surgery
    • /
    • v.28 no.1
    • /
    • pp.23-30
    • /
    • 1995
  • From January 1985 to December 1992, of 1257 patients who underwent a heart valve replacement 210 [16.8% underwent reoperation on prosthetic heart valves, and 6 of them had a second valve reoperation. The indications for reoperation were structural deterioration [176 cases, 81.5% , prosthetic valve endocarditis [25 cases, 11.6% , paravalvular leak [12 cases, 5.6% , valve thrombosis [2 cases, 0.9% and ascending aortic aneurysm [1 case, 0.4% . Prosthetic valve failure developed most frequently in mitral position [57.9% and prosthetic valve endocarditis and paravalvular leak developed significantly in the aortic valve [40%, 75% [P<0.02 . Mean intervals between the primary valve operation and reoperation were 105.3$\pm$28.4 months in the case of prosthetic valve failure, 61.5$\pm$38.5 months in prosthetic valve endocarditis, 26.8$\pm$31.2 months in paravalvualr leak, and 25.0$\pm$7.0 months in valve thrombosis. In bioprostheses, the intervals were in 102.0$\pm$23.9 months in the aortic valve, and 103.6$\pm$30.8 months in the mitral valve. The overall hospital mortality rate was 7.9% [17/26 : 15% in aortic valve reoperation [6/40 , 6.5% in reoperation on the mitral prostheses [9/135 and 5.7% in multiple valve replacement [2.35 . Low cardiac output syndrome was the most common cause of death [70.6% . Advanced New York Heart Association class [P=0.00298 , explant period [P=0.0031 , aortic cross-clamp time [P=0.0070 , prosthetic valve endocarditis [P=0.0101 , paravalvularr leak [P=0.0096 , and second reoperation [P=0.00036 were the independent risk factors, but age, sex, valve position and multiple valve replacement did not have any influence on operative mortality. Mean follow up period was 38.6$\pm$24.5 months and total patient follow up period was 633.3 patient year. Actuarial survival at 8 year was 97.3$\pm$3.0% and 5 year event-free survival was 80.0$\pm$13.7%. The surgical risk of reoperation on heart valve prostheses in the advanced NYHA class patients is higher, so reoperation before severe hemodynamic impairment occurs is recommended.

  • PDF

Clinical experience of open heart surgery: 12 cases (개심술 치험 보고: 12예)

  • 최영호
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.289-294
    • /
    • 1983
  • The report is concerned to our experience of 12 cases of open heart surgery under the extracorporeal circulation at the Department of Thoracic and Cardiovascular Surgery, Chosun University Hospital during the period between Nov, 1979 and April, 1983. 1. There were 4 cases of congenital anomaly and 8 cases of acquired heart disease. 2. There were 6 male and 6 female patients with a mean age of 20 years. [range 9 to 33 years]. 3. The cases induced 2 ventricular septal defect, 2 atrial septal defects and 8 acquired valvular heart diseases. 4. The surgical managements were 2 primary repair for atrial septal defect and 2 patch closure for ventricular septal defect, 1 triple valve replacement [AVR MVR TVR], 1 aortic valve replacement, 4 double valve replacement [AVR MVR] and 2 open mitral commissurotomy for pure mitral stenosis. 5. The average cardiopulmonary bypass time was 61.5 minutes for congenital heart disease and 201.4 minutes for acquired valvular heart disease and the average aortic cross clamping time was 36.75 minutes for the former and 165.6 minutes for the latter. 6. Postoperatively, there were 1 Alopecia, 1 Electric burn and 1 wound infection as complication. 7. Overall operative mortality was 8.3%. 7. All patients received valve replacement were recommended anticoagulation with persantin.

  • PDF

Intractable Hemoptysis due to Valvular Heart Disease Treated by Emergency Redo DVR: 1 case report (판막부전증에 의한 대량객혈의 응급 이중판막 재치환술: 1례 보고)

  • 이재훈;전양빈
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.423-427
    • /
    • 1997
  • Hemoptysis occurs quite frequently as a consequence of mitral stenosis, but massive, lirE threatening pulmonary hemorrhage is distinctly unusual. We report a 30 year old female who underwent cmcrgcncy rcdo double valve replacement for intractable pulmonary hemorrhage. she underwent mitral valve replacement (lonescu Shirley 27 mm) due to rheumatic valvular heart disease in 1984 and tricuspid valve annuloplasty (Carpentier's rlng 30mm) two years later She was admitted for massive hcmoptysis and dyspnea on the 26th of December, 1995. Medical treatment including transarterial embolization was given but was not satisfactory. Emergency valve replacement (Mitral valve , 51. Judc 29mm and tricuspid valve ; 51. Jude 33mm) was performed and hemoptysis was controlled dramatically 24 hours after surgery.

  • PDF