• Title/Summary/Keyword: heart valve prosthesis

Search Result 114, Processing Time 0.025 seconds

Early Outcomes of Sutureless Aortic Valves

  • Hanedan, Muhammet Onur;Mataraci, Ilker;Yuruk, Mehmet Ali;Ozer, Tanil;Sayar, Ufuk;Arslan, Ali Kemal;Ziyrek, Ugur;Yucel, Murat
    • Journal of Chest Surgery
    • /
    • v.49 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was $71.15{\pm}8.60years$. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was $56.9{\pm}9.93$. The CPB time was $96.51{\pm}41.27minutes$ and the cross-clamping time was $60.85{\pm}27.08minutes$. The intubation time was $8.95{\pm}4.19hours$, and the intensive care unit and hospital stays were $2.89{\pm}1.42days$ and $7.86{\pm}1.42days$, respectively. The mean quantity of drainage from chest tubes was $407.69{\pm}149.28mL$. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was $687.24{\pm}24.76days$. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

Significance of Microembolic Signals during Oxygen Inhalation in Patients with Prosthetic Mechanical Heart Valve (인공 기계 심장 판막 이식 환자에서 산소 흡입 중 미세색전 신호의 중요성)

  • 조수진;나찬영;이은일;민양기;권기한;이정주;백만종;오삼세;홍석근
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.50-55
    • /
    • 2004
  • Background: Transcranial Doppler ultrasonography (TCD) can detect microembolic signals (MES) in the patients with a potential embolic source. Clinical significance of MES has not been demonstrated in patients with prosthetic mechanical heart valves. We studied the correlation between cerebral thromboemoblic events after the mechanical heart valve surgery (MHVS) and residual MES during TCD monitoring with 100% oxygen inhalation in patients with mechanical heart valves. Material and Method: Twenty patients with previous cerebral thromboemoblic events after MHVS and a sex- and age-matched control group (n=30) were studied. TCD monitoring was performed from unilateral middle cerebral artery. After baseline monitoring for 20 minutes, 61 of oxygen was inspired for 40 minutes. Result: The site of valve and the duration after MHVS of the patients did not differ from those of controls. During baseline monitoring, there was no significant difference in MES prevalence or counts compared to controls. During oxygen inhalation, patients showed a higher MES prevalence (55%, 27.6%, p=0.045) and a more frequent MES counts (p=0.027) compared to controls. Conclusion: TCD monitoring with oxygen inhalation may be useful to differentiate clinically significant MES in patients with mechanical heart valve.

Early Clinical Outcome and Doppley Echocardiographic Data after Cardiac Valve Replacement with the ATS prosthesis (ATS 인공 판막의 조기 임상성적 및 도플러 심에코 검사 소견)

  • 박계현;박승우
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.663-669
    • /
    • 1997
  • This is a report on the clinical outcome and hemodynamic profile of the ATSwcardiac valve prosthesis, which is a recently introduced pyrolytic carbon bileaflet prosthesis. We retrospectively reviewed the early outcome of 100 consecutive patients who underwent isolated cardiac valve replacement with the ATS(w prosthesis from October 1994 through June 1996 at our hospital. All patients were evaluated with Doppler echocardiography before discharge from the hospital. The mean age of the patients was 48.6 years(range: 2 to 74). A tota of 124 prosthesis were implanted; 71 mitral, 46 aortic, and 7 tricuspid. The two most frequently used sizes were 27 mm(40.8%) and 29 mm(35.2%) in the mitral position, and 23 mm(30.4%) and 21 mm(28.3%) in the aortic position. There was no early or late death. The total follow-up period was 950 patient-months with 99% follow-up rate. Serious late morbidity occurred in three patients; reoperation in two patients for late rupture of Sinus of Valsava in one and for endocarditis with prosthetic dehiscence in the other, and intracranial hemorrhage due to hypertension in one patient. There has been no thromboembolic complication or structural valval deterioration. In the mitral position, the average values of peak and mean transprosthetic pressure gradients and valve area calculated from pressure half time were 6.9$\pm$2.8 mmHg, 2.6$\pm$ 1.5 mmHg, and 2.7 $\pm$0.8 cm2 respectively. In the aortic position, the peak and mean pressure gradients'were 26.4 $\pm$ 15.9 mmHg and 14.2 $\pm$ 7.9 mmHg. For the mitra prostheses larger than 25-mm size, there was no significant difference among prosthetic sizes in terms of transprosthetic gradients, whereas there was a significant negative correlation between the prosthesis size and the transprosthetic gradients for the aortic valves. The peak and mean Pressere pradients were 52.2 $\pm$ 17.6 tmHg and 26.9$\pm$ 7.4 mmHg across the 19-mm aortic Prostheses, and 27.1 $\pm$ 11.9 mmHg and 13.3$\pm$6.6 mmHg across the 21-mm size. Above results can lead to the conclusion that the early clinical outcome of the ATS valve prosthesis is quite satisfactory, And the hemodynamic characteristics are comparable, if not better, with other bileaflet prostheses.

  • PDF

Pregnancy in Patients with Prosthetic Heart Valve (심장판막을 대치 받은 환자에서의 임신)

  • 이석열;장병철;박한기;박용원;강면식;홍승록;조범구;홍필훈
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1023-1030
    • /
    • 1999
  • This is a retrospective study of 42 pregnancies from 33 women with prosthetic heart valves who were on anticoagulation regimen prior to or during their pregnancy. Material and Method: Of the 17 women with bioprosthesis, 15 had 21 pregnancies following cessation of the anticoagulation therapy which resulted in the delivery of 20 healthy babies and 1 abortion. Remaining 2 had 3 pregnancies maintained with heparin, resulting in 2 healthy babies and 1 spontaneous abortion. Result: Among 16 women with mechanical heart valves, there were 7 pregnancies during which warfarin was used and this was associated with 4 fetal wastages(2 therapeutic abortion, 1 spontaneous abortion and 1 stillbirth with cerebral hemorrhage). However, in pregnancies where heparin was used, there was no fetal wastage. A patient who did not take anticoagulant for the first trimester and took warfarin for the remaining period and a patient who did not take anticoagulant during pregnancy delivered normal babies. There was an other fetal wastage in a patient on anti-platelet therapy for the first trimester and warfarin therapy for the remaining periods. There was 1 minor petechial complication in a heparin administered group. Conclusion: The study indicates that woman with bioprosthetic heart valves can go through pregnancy without undue risks or complications. On the other hand, the use of warfarin during pregnancy in women with mechanical heart valves, was shown to be associated with unacceptable high risk for the fetus. However, in the same group of women, judicious use of heparin during pregnancy was accompanied by a much reduced risk. The safety and adequate therapeutic range of heparin usage under such circumstances are subject to further studies.

  • PDF

Long Term Clinical Results of Duromedics Valve (Duromedics 판막의 장기 임상 성적 고찰)

  • Jeong, Dong-Seop;Lim, Chung;Kim, Kyung-Hwan;Kim, Ki-Bong;Aun, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.686-691
    • /
    • 2001
  • Background: The Duromedics valve has been used in Korea since 1982, however, but there were no long term clinical results that have been reported. This paper presents the long term clinical results of Duromedics valve implanted in Seoul National University Hospital. Material and method: Between 1987, 23 patients underwnet cardiac valve replacement with Duromedics mechanical valve. There were 8 mitral valve replacements, 5 aortic valve replacements, one tricuspid valve replacement, 6 aortic and mitral valve replacements, and one mitral and tricuspid valve replacement. There were 12 men and 11 women. The mean age was 35$\pm$10(15~52) years. We evaluated the clinical performance of Duromedics cardiac prosthesis. Result: The early operative mortality was 4.3%(1/23) and the late morlatity was 4.3%(1/23). Causes of death were low cardiac output syndrome and structural valvular failure. The mean follow-up duration was 133$\pm$43(8~157) months. There were 3 reoperations. The causes of reoperations were thrombosis and structural failure and nonstructural valvular failure. The actuarial survival rate at 10 years was 90.9%. Conclusion: Although the number of patients was not sufficient for effective clinical study, the long term clinical results of Duromedics valve was relatively good and there was no structural defect in this mechanical valve. However, more research is needed in the future.

  • PDF

Reoperation for Dysfunction of Cardiac Valve Prosthesis (인공 심장판막 기능부전 환자에서의 심장판막 재치환술)

  • 윤정섭;김치경;조규도;이성호;곽문섭;김세화
    • Journal of Chest Surgery
    • /
    • v.31 no.3
    • /
    • pp.242-246
    • /
    • 1998
  • From January 1988 to December 1995, 27 patients, 11 men and 16 women, underwent surgical intervention at our institution for prosthetic valve dysfunctions. The mean age was 43.5$\pm$12.2 years. Seventeen(63.0%) patients had the mitral valve replacement, 8(29.6%) the aortic valve, 1(3.7%) the aortic composite graft, and 1(3.7%) the tricuspid valve. Mean follow-up period was 49.5$\pm$30.9 months. In 12 bioprostheses, mean interval between the previous valve replacement and the reoperation was 104.9$\pm$34.9 months. The causes of redo surgery were structural deterioration of the prosthetic valve (12/12, 100%), paravalvular leak (2/12, 16.7%), and prosthetic valve endocarditis(1/12, 8.3%). In 15 mechanical prostheses, the mean interval was 55.2$\pm$43.7 months. The causes of redo surgery were pannus formation (8/15, 53.3%), paravalvular leak(4/15, 26.7%), and valve thrombosis(3/15, 20.0%). Posto- perative complications occurred in 7 patients (25.9%). There was no intraoperative death. But one patient, who received mechanical aortic valve replacement died on the 3rd postoperative day due to low cardiac output and multiorgan failure.

  • PDF

Multiple Embolic Aortic Valve Endocarditis with Small Patent Ductus Arteriosus in Adult

  • Kim, Seon Hee;Song, Seunghwan;Kim, Min Su;Kim, Sang-Pil;Choi, Jung Hyun
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.137-140
    • /
    • 2014
  • A 50-year-old female was admitted to Pusan National University Hospital with complaints of fatigue and sweating. Echocardiography showed a small patent ductus arteriosus (PDA) and highly mobile vegetations on the aortic valve. Emergency operation was performed due to the high risk of embolization and severe aortic regurgitation. When the pulmonary artery opened, we found unexpected fresh vegetation. The tissue of the PDA was fragile and infected. We successfully removed the infected tissue, closed the PDA with a patch, and replaced the aortic valve with a mechanical prosthesis.

Surgical Treatment of Multivalvular Endocarditis with Ventricular Septal Defect (심실중격결손과 동반한 다중판막 감염성 심내막염의 수술적 치료)

  • Kim, Seon-Hee;Je, Hyoung-Gon;Lee, Sang-Kwon;Kim, Sang-Pil
    • Journal of Chest Surgery
    • /
    • v.43 no.4
    • /
    • pp.417-420
    • /
    • 2010
  • As higher mortality rate and frequent incidence of morbidity, early surgical treatment is generally recommended for the multivalvular endocarditis. A 46-year-old female presented with high fever. Echocardiography showed the vegetation on pulmonic valve, tricuspid valve and mitral valve with a ventricular septal defect. Emergency operation was conducted due to uncontrolled infection. We present a clinical success of this rare case with review of the medical literature.

Enoxaparin as an Anticoagulant in a Multipara with a Mechanical Mitral Valve: A Case Report

  • Yo Seb Lee;Jun Seok Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.452-455
    • /
    • 2023
  • Patients who have undergone mechanical valve replacement require anticoagulation therapy with warfarin to prevent thromboembolism. However, administering warfarin to pregnant patients increases their risk of warfarin embryopathy or central nervous system disorders. Consequently, safer alternatives, such as heparin or low-molecular-weight heparin injection, are substituted for warfarin. However, limited research has been conducted on this subject, with no large-scale studies and particularly few investigations involving multiparous patients. A patient who had previously undergone mechanical mitral valve replacement for atrial septal defect and mitral stenosis received anticoagulant therapy with enoxaparin during 2 pregnancies. Upon confirmation of pregnancy, warfarin was replaced with subcutaneously injected enoxaparin with a dosage of 1 mg/kg at 12-hour intervals. The enoxaparin dosage was controlled using an anti-factor Xa assay, with a target range of 0.3-0.7 IU/mL. Intravenous heparin injections were administered starting 3 days prior to the expected delivery date and were continued until delivery, after which warfarin was resumed. No complications were observed during the deliveries.

Long-Term Clinical Results of Tricuspid Valve Replacement (삼첨판막 대치술의 장기간 임상성적)

  • 임상현;홍유선;유경종;강면식;김치영;조범구;장병철
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.328-334
    • /
    • 2004
  • There are only limited numbers of reports about long-term results of tricuspid valve replacement(TVR) with bioprosthetic and mechanical prostheses. We analyzed risk factors for tricuspid valve replacement and compared long-term clinical results of bioprosthetic and mechanical valves in tricuspid position. Material and Method: We reviewed 77 cases of TVR, which were performed between October 1978 and December 1996. Mean age was 38.8 15.9 years. Bioprostheses were implanted in 26 cases and mechanical prostheses were implanted in 51 cases. Result The operative mortality was 15.6% and late mortality was 12.3%. Survival for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 81.3% vs. 100%, 66.1% vs. 100%, 60.6% vs. 100% (p=0.0175). Free from valve related re-operation for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 100% vs. 93.9%, 100% vs. 93.9% and 58.3% vs. 93.9% (p=0.3274). Linealized incidences of valve related re-operation for bioprosthetic and mechanical valve group was 2.27 %/patient-years and 1.10 %/patient-years. Risk factor analysis showed that presence of preoperative ascites, hepatomegaly larger than 2 finger breaths, poor preoperative NYHA functional class and number of tricuspid valve replacement were risk factors for early mortality, and the use of bioprosthetic valve and number of open heart surgery were risk factors for late mortality. Conclusion: Long-term survival of mechanical valve was superior to bioprosthetic valve in tricuspid position. We recommend mechanical valve in tricuspid position if the patient can be closely followed up.