• 제목/요약/키워드: heart valve disease

검색결과 286건 처리시간 0.045초

개심술 204례의 임상적 고찰 (Clinical experience of open heart surgery: a report of 204 cases)

  • 문병탁
    • Journal of Chest Surgery
    • /
    • 제17권2호
    • /
    • pp.305-314
    • /
    • 1984
  • From May 1977 to April 1984, 204 cases of open heart surgery were performed under cardiopulmonary bypass. There were 99 male and 105 female patients ranging in age from 19 months to 58 years. 136 cases [66.7%] were congenital heart disease, and 68 cases [33.3%] were acquired heart disease, which were 66 valvular disease [97.1%], 1 IVC obstruction, and 1 myxoma. There were 136 congenital heart anomaly with 16 operative deaths [11.8%], consisting of 94 acyanotic cases with 7 death [7.4%] and 42 cases of cyanotic cases with 9 deaths [21.4%]. In 66 patients of acquired valvular disease, 52 valves were implanted; 47 mitral valve replacement with 4 death [8.5%] and 5 double valve replacement [MVR+AVR] with 1 death [20%]. Postoperative, warfarin sodium was medicated with checking prothrombin time. Finally, the operative mortality was 11.8% in congenital anomaly, and 11.8% in acquired heart disease, overall mortality rate was 8.5%.

  • PDF

센 쥬드 판막의 혈류 역학적 고찰 (Hemodynamic Evaluation of St. Jude Medical Prosthesis)

  • 문광덕
    • Journal of Chest Surgery
    • /
    • 제28권12호
    • /
    • pp.1122-1131
    • /
    • 1995
  • One hundred eighty-eight patients[August.23,1988,through July.30,1994 underwent aortic[AVR , mitral[MVR , or double [DVR valve replacement with the St.Jude Medical prosthesis. The author analyzed 100 patients with valvular heart disease,who underwent valve replacement with the St.Jude Medical prothesis from 1990 to 1994, at Hanyang University hospital Cardiovascular department. Information on volume and functional change of the heart chamber can be obtained by cardiac echocardiography and cartheterization. Out of 100 patients, 40 patients were male[40% and 60 patients were female [60% . Age ranged from 13 years to 68 years, with mean age of 42.6 years. Mean height was 160.3cm and mean body weight was 54.9Kg. According to NYHA functional classification, class III is most frequent and 60 patients could be classfied under it. MVR [involved Redo MVR was performed in 40 patients, AVR [involved Redo AVR was performed in 18 patients, and DVR [involved Redo DVR was performed in 42 patients. Warfarin [Coumadin anticoagulation was recommended for all patients. Life long warfarin anticoagulation was necessary to all patients who underwent valve replacement with St.Jude Medical prosthesis. Ideal prothrombin time was maintained about 30% during warfarinization. There were no case of mechanical failure. It followed a comparison of echocardiography before and after valve replacement at Hanyang University hospital [30 patients and a preoperative evaluation of cardiac catheterization and angiography [64 patients . The St.Jude Medical cardiac valve is a viable alternative in the surgical therapy of valvular heart disease.

  • PDF

개심술 치험 보고: 12예 (Clinical experience of open heart surgery: 12 cases)

  • 최영호
    • Journal of Chest Surgery
    • /
    • 제16권3호
    • /
    • pp.289-294
    • /
    • 1983
  • The report is concerned to our experience of 12 cases of open heart surgery under the extracorporeal circulation at the Department of Thoracic and Cardiovascular Surgery, Chosun University Hospital during the period between Nov, 1979 and April, 1983. 1. There were 4 cases of congenital anomaly and 8 cases of acquired heart disease. 2. There were 6 male and 6 female patients with a mean age of 20 years. [range 9 to 33 years]. 3. The cases induced 2 ventricular septal defect, 2 atrial septal defects and 8 acquired valvular heart diseases. 4. The surgical managements were 2 primary repair for atrial septal defect and 2 patch closure for ventricular septal defect, 1 triple valve replacement [AVR MVR TVR], 1 aortic valve replacement, 4 double valve replacement [AVR MVR] and 2 open mitral commissurotomy for pure mitral stenosis. 5. The average cardiopulmonary bypass time was 61.5 minutes for congenital heart disease and 201.4 minutes for acquired valvular heart disease and the average aortic cross clamping time was 36.75 minutes for the former and 165.6 minutes for the latter. 6. Postoperatively, there were 1 Alopecia, 1 Electric burn and 1 wound infection as complication. 7. Overall operative mortality was 8.3%. 7. All patients received valve replacement were recommended anticoagulation with persantin.

  • PDF

개심술 치험 60례 보 (Clinical analysis of 60 cases of open heart surgery)

  • 김수성;김영호;김공수
    • Journal of Chest Surgery
    • /
    • 제17권3호
    • /
    • pp.389-397
    • /
    • 1984
  • Sixty cases of open heart surgery were performed in the Department of Thoracic and Cardiovascular Surgery of Chonbuk National University Hospital from July, 1983 to June, 1984. The patients were consisted of 40 [66%] congenital anomalies containing 26 [43%] patients of acyanotic group and 4 [23%] of cyanotic group, and 20 [34%] acquired heart diseases which involved one or more cardiac valves. The male patients were 42 and the female 18. In 20 valvular heart diseases, open mitral commissurotomy was done in 5 patients, mitral valvular replacement with tissue valve in 6, mitral valvular replacement with mechanical valve in 5, mitral valvular replacement with tricuspid annuloplasty in 2, mitral annuloplasty in 1, and mitral and aortic valvular replacements with mechanical valves in 1. The most frequency complication was low cardiac output syndrome occurred in 9, and the next was urethral stenosis, ARDS, and postoperative bleeding, etc. The perioperative mortality was 21% in congenital cyanotic heart disease, 12% in congenital acyanotic heart disease, and 5% in acquired heart disease.

  • PDF

인공심장판막의 개발 및 동물실 (Development and Animal Tests of Artificial Heart Valves)

  • 이재영
    • Journal of Chest Surgery
    • /
    • 제20권3호
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

1978년도 상반기 개심술 : 112례 보고 (Open Heart Surgery in the First Half of 1978: A Report of 112 Cases)

  • 이영균
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.281-295
    • /
    • 1978
  • Last year in this department 100 cases of open heart surgery were done annually. This year 200 cases of open heart surgery were scheduled. During the first 6 months of this year 112 open heart surgery cases were done with 13 deaths [11.6%]. There were 72 cases of cougenital malformation with 9 operative deaths [12.5%], consisting of 23 acyanotic cases with one death [4.5%] and 49 cases of cyanotic cases with 8 deaths [16.3%]. Out of 40 tetralogy of Fallot, 6 cases expired [15%]. For 39 cases of acquired valvular heart disease and one Ebstein anomaly valves were replaced with 4 operative deaths [10%]. Single valve replacement in 33 with 3 operative deaths and double valve replacement in 7 cases with one death were noted. Two patients expired among 28 mitral valve replacement cases [7.1%]. Among 7 double valve replacement patients, consisting of 3 mitral and aortic and 4 mitral and tricuspid valve replacement one case expired. In a case of Ebstein anomaly, tricuspid valve was replaced with plication of atrialized right ventricle successfully. The operative result was excellent.

  • PDF

심장질환의 외과적 요법에 관한 연구: II.후천성 심장질환, 1. 판막대치 이식수술 (Surgical Treatment of Heart Disease: II. Acquired Heart Disease I: Valve Replacement)

  • 이영균;서경필
    • Journal of Chest Surgery
    • /
    • 제10권2호
    • /
    • pp.315-326
    • /
    • 1977
  • From 1958 to October 1977, 294 cases of acquired heart disease were operated. There were 68 cases of pericardium, 3 trauma, 2 foreign body, one cardiac thrombus, 3 atrial myxoma, 2 left atrial and 1 right atrial, 2 Budd-Chiari syndrome, and 214 valvular heart disease. Out of 214 cases of valve operation 73 valves were replaced in 64 patients. Male to female ratio was 1.46: 1. The youngest age was 14 years in male and 18 in female. The oldest was 54 years in male and 52 in female. Fifty-five cases of single valve were replaced, consisting of 47 mitral and 8 aortic valves. There were 9 double valve replacement cases which consist of 7 mitral and aortic and 2 mitral .and tricuspid valves. Six varieties of prosthetic valves, 3 ball and 3 disc types and 3 kinds of xenograft tissue valves were utilized. Beall, BjSrk-Shiley and Starr-Edwards prosthetic valves and Hancock valves were used mainly. For single valve 34. 5% and for double valve replacement 44% mortality were noted. There were 23 operative deaths out of 64 patients, over all mortality rate of 36.9%. Mortality for mitral valve replacement was 29.5%. But in recent 12 consecutive cases one death occurred, showing 8.3% mortality. In earlier days thrombocyte anti-adhesive drug dipyramidole-persantin-aspirin and/or SP 54 were adminstered. But in recent cases after heparinization, coumadin and Persantin were prescribed routinely.

  • PDF

승모판막질환을 합병한 심방중격결손증의 수술요법6례 보고 (Coexistent Atrial Septal Defect with Mitral Valve Disease: a report of 6 cases)

  • 조성래;채헌;노준량
    • Journal of Chest Surgery
    • /
    • 제12권4호
    • /
    • pp.339-345
    • /
    • 1979
  • Mitral valve disease is the most common disease of the acquired heart diseases, and atrial septal defect is also one of common congenital heart diseases. Coexistence of these two lesions is rare, but of great hemodynamic interest. Among 443 cases with mitral valve disease and 90 cases with atrial septal defect experienced in the Department of Thoracic Surgery, Seoul National University Hospital, there were 6 cases with atrial septal defect complicated by mitral valve disease. 1. Of the 6 patients, four were female and two were male. The age was ranged from 18 to 46. 2. Atrial septal defect was ostium secundum type in all cases, and the mitral valvular lesions were regurgitation in four and stenosis in two. Type II ventricular septal defect was also combined in one of the cases. 3. The atrial septal defect was corrected by, primary closure and the mitral valve was replaced with the prosthetic or bioprosthetic valve in all cases. The combined ventricular septal defect was closed using Teflon felt patch. 4. The operative result was good except in one who was expired of bacterial endocarditis 4 months after hospital discharge.

  • PDF

판막부전증에 의한 대량객혈의 응급 이중판막 재치환술: 1례 보고 (Intractable Hemoptysis due to Valvular Heart Disease Treated by Emergency Redo DVR: 1 case report)

  • 이재훈;전양빈
    • Journal of Chest Surgery
    • /
    • 제30권4호
    • /
    • pp.423-427
    • /
    • 1997
  • 객혈은 승모판막협착증의 영향으로 흔히 발생되지만,많은 양으로 지속적이며 치명$\boxUl$101 곤출친으 확 실히 드물다. 한양대 학교 흉부외과학교실에서는 지속적인 대량 폐출혈로 응급이중판막 재치환술 시행받은 30대 여자의 예를 보고하고자 한다. 환자는 1984년 류마치스성 승모판막 폐쇄부전증으로 판막치환술을(lonescu Shilcy 27mm) 받았으며, 그후 2년후에 삼첨판윤 성형술(Carpcntier's ring 30mm)을 받았다. 1995년 12월 26일 환자는 대량 객혈과 심한 호흡곤란으로 입원하였다. 객혈에 대한 동맥색전술을 포함한 내과적 치료를 시행 받았지만 효과는 없었다. 환자는 응급 이중판막 재치환술(승모판 : St. Jude 29mm, 삼첨판; St. Jude 33mm)을 시 행 받았으며. 술후 24시간이 경과된 후 객혈은 극적으로 조절되었다.

  • PDF

후천성 심질환의 인공판막치환술에 대한 임상적 고찰 (Clinical Analysis of Prosthetic Valve Replacement on Acquired Heart Disease)

  • 이준영;지행옥
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.951-959
    • /
    • 1989
  • Between September, 1972 and September, 1989, total 359 patients were operated for acquired heart disease at Department of Thoracic and Cardiovascular Surgery, Hanyang University Hospital. A consecutive series of 293 prosthetic valve replacement was also performed during this period. The results were summarized as follows; 1. There were 141 men and 218 women, whose ages ranged from 6 to 64 years, [mean 35.5 years] 2. Out of 293 cases, mitral valve replacement was 182 cases, aortic valve replacement was 39 cases and double valve replacement was70 cases. 3. Early post-operative death was 30 cases [Mortality; 8.4 %] and late death was 9 cases in the survivors. 4. Re-operation was 30 cases and operative mortality was 10%. 5. Mean post-operative interval was 76 months. [Ranged from 216 months to 2 months] 6. Among re-operation cases, primary prosthetic valve failure was 16 cases and paravalvular leakage was 2 cases. 7. Since January 1988, 79 cases of prosthetic valve replacement were performed and then 1 case was expired. [Mortality; 1.2 %]

  • PDF