• Title/Summary/Keyword: heart extraction

Search Result 134, Processing Time 0.025 seconds

P-wave Detection Algorithm by Significant Point Extraction Method (특성점 추출에 의한 P파 검출 알고리즘에 관한 연구)

  • Hwang, Sun-Chul;Jeong, Hee-Kyo;Lee, Myoung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.162-165
    • /
    • 1989
  • This paper describes an algorithm of P-wave detection by significant point extraction method with digital differentiation. P-waves are detected by pattern matching algorithm with significant points. By means of defecting onset and offset points of P-waves, this algorithm can measure the PR intervals exactly which is important to diagnosis the atrial arrhythmia. Because P-wave duration is changed according to heart-rates, we calculate the R-R interval prior to the determination of P-wave duration threshold values in order to actively adapt to the change of P duration The results obtained from the proposed algorithm have defected successfully P-wave almost more than 90%.

  • PDF

Design of a hardware system for ECG feature extraction (ECG 특징추출을 위한 하드웨어시스템의 설계)

  • 이경중;윤형로;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.697-700
    • /
    • 1988
  • This paper describes the design of a hardware system for ECG feature extraction based on pipeline processor consisting of three computers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggred detector. Four diagnostic parameters-heart, axis, and ST axis, and ST segment are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken 1% of one clock period.

  • PDF

R-to-R Extraction and Preprocessing Procedure for an Automated Diagnosis of Various Diseases from ECG Data

  • Timothy, Vincentius;Prihatmanto, Ary Setijadi;Rhee, Kyung-Hyune
    • Journal of Multimedia Information System
    • /
    • v.3 no.2
    • /
    • pp.1-8
    • /
    • 2016
  • In this paper, we propose a method to automatically diagnose various diseases. The input data consists of electrocardiograph (ECG) recordings. We extract R-to-R interval (RRI) signals from ECG recordings, which are preprocessed to remove trends and ectopic beats, and to keep the signal stationary. After that, we perform some prospective analysis to extract time-domain parameters, frequency-domain parameters, and nonlinear parameters of the signal. Those parameters are unique for each disease and can be used as the statistical symptoms for each disease. Then, we perform feature selection to improve the performance of the diagnosis classifier. We utilize the selected features to diagnose various diseases using machine learning. We subsequently measure the performance of the machine learning classifier to make sure that it will not misdiagnose the diseases. The first two steps, which are R-to-R extraction and preprocessing, have been successfully implemented with satisfactory results.

Design of Pipeline Processor for ECG Feature Extraction (ECG 특징추출을 위한 파이프라인 프로세서의 설계)

  • 이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 1988
  • This paper describes the design of a hardware systenl for ECG feature extraction based on pipeline processor consistinsf of three microcomputers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggered detector. Four diagnostic parameters parameters-heart rate, morPhology, axis, and 57 segment-are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken Loye of one clock period.

  • PDF

Surface Activities of Ginseng Saponins and Their Interactions with Biomolecules'(V) Ginseng Saponins Can Be Vsed in Cytochrome c Isolation (인삼사포닌의 계면활성 및 생체 분자와의 작용 : (V) 미토콘드리아 Cytochrome c 단리에서 인삼사포닌의 추출효과)

  • Lee, Jae-Yang;Lee, Sang-Jik
    • Journal of Ginseng Research
    • /
    • v.19 no.2
    • /
    • pp.122-126
    • /
    • 1995
  • The effects of treating bovine heart mitochondria with potassium chloride and surfactants such as digitonin and n-dodecy-$\beta$-maltoside (DMS) including plant saponins on extracting cytochrome c were examined. The spectra given by the cytochrome c-containing solutions from the extraction were inspected to ascertain whether ginseng and bellflower saponins could be used instead of the generally- employed surfactants of digitonin and DMS. These studies implied that the effect of ginseng saponins is superior to that of digitonin but inferior to that of DMS, and give rise to the idea of substitutional property of ginseng saponins for the widely-employed surfactants in the extraction of mitochondria intermembrane cytochrome c. The substitution for the solubilizing surfactants by bellflower saponins could, however, not presumably be anticipated; while ginseng saponin mixture are a suitable substitute.

  • PDF

Effects of Mechanochemical Pretreatment on the Extraction of Functional Materials from Houttuynia cordata

  • Park, Keum-Joo;Song, Won-Seob;Islam, Mohammad Nazrul;Lee, Jong-Ill;Kim, Yang-Soo
    • Korean Journal of Plant Resources
    • /
    • v.24 no.3
    • /
    • pp.309-313
    • /
    • 2011
  • Houttuynia cordata is used as a raw material of oriental medicine to acquire antioxidant and anti cancer effect and to cure a heart disease. Mechanochemical technology not only reduces the size of the object but also changes the chemical properties of the object. Extraction of functional materials from the Houttuynia cordata after grinding as a pretreatment using the mechanochemical technology was conducted in this study to investigate the effect of grinding on the yields and antioxidant activities of the extract. Houttuynia cordata was ground by the planetary ball mill and the morphology was analyzed by SEM. Yields of functional materials were increased from 6.2 g in the sample without grinding to 7.0, 7.8, 8.8 g after grinding of 30 minutes, 1 hour and 2 hours, respectively. Nitrite scavenging abilities were increased from 57-77% to 69-86% as a result of mechanochemical pretreatment. Also, DPPH scavenging abilities for the methanol extraction were increased from 10.01-40.29% to 11.01-49.29% as a result of mechanochemical grinding.

Osteomyelitis following extraction of lower third molar during pregnancy (임신 중 하악 제3대구치 발거후 발생한 골수염)

  • Lee, Sang-Bin;Huh, Kyung-Hoe;Yi, Won-Jin;Kim, Mi-Ja;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.177-182
    • /
    • 2008
  • A 27-year-old female was referred to our hospital postpartum due to rapid aggravation of facial swelling. She was diagnosed with osteomyelitis on clinical, radiological, and histopathological examinations, but the possibility of malignancy was not excluded. Clinical signs and symptoms such as facial swelling and discomfort were improved with four months of antibiotics treatment. This is as case of an osteomyelitis progressed from infected extraction socket in a woman with physiological changes of pregnancy. Decreased immunological response, increased sex hormone and calcium regulatory hormones regulate the response of the bone infection. We report this case for helping the diagnosis of unusual from of osteomyelities in pregnancy and postpartum.

  • PDF

Comparative randomized study of propofol target-controlled infusion versus sevoflurane anesthesia for third molar extraction

  • Chung, Patrick K;Dhanrajani, Parmanand
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.169-175
    • /
    • 2018
  • Background: The objective of this study was to compare hemodynamic and recovery characteristics of total intravenous anesthesia using propofol target-controlled infusion (TCI) versus sevoflurane for extraction of four third molar teeth. Methods: One hundred patients undergoing extraction of four third molar teeth under general anesthesia were randomized to one of two groups. Group 1 received propofol TCI-oxygen for induction and propofol TCI-oxygen-air for maintenance. Group II received a propofol bolus of 2 mg/kg for induction and sevoflurane-oxygen-air for maintenance. Heart rate, mean arterial pressure (MAP), operating time, time to emergence, nausea and vomiting, and sedation and pain scores were measured in each group. Results: Demographic data, including age, gender, weight, and height, were not significantly different between the two groups. The MAP was significantly higher after intubation (P = 0.007) and injection of anesthesia (P = 0.004) in the propofol group than in the sevoflurane group, with significant reflex bradycardia (P = 0.028). The mean time to emergence from anesthesia using propofol was 25 s shorter than that of sevoflurane (P = 0.02). Postoperatively, the propofol group was less sedated than the sevoflurane group at 30 min (0.02 versus 0.12), but this difference was not significant (P = 0.065). Conclusion: Both propofol TCI and sevoflurane are good alternatives for induction and maintenance of anesthesia for short day-case surgery. However, propofol TCI does not blunt the hemodynamic response to sudden, severe stimuli as strongly as sevoflurane, and this limitation may be a cause for concern in patients with cardiac comorbidities.

Tracking of Continuously Acting Hearts Using a Geometric Active Contour Model (기하 활성 모델을 이용한 연속적 심장 운동 추적)

  • 김성곤
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.17-22
    • /
    • 2002
  • This paper used an active contour model which was based on level set algorithms and bidirectional curve evolution theory in order to track the shape of the heart acting continuously. Most active contour models would be failed in boundary extraction because of their unstable movement in the edge gap locations. In this paper, we suggest a new active contour model using only image intensity value and additional constraint needed for stable extraction. Our model was successfully run on either shape extraction or object tracking without any position constraints of initial curve. Also demonstrated stable movements and showed good results at weak or missing boundary locations.

  • PDF

Optimal Thoracic Sound Data Extraction Using Principal Component Analysis (주성분 분석을 이용한 최적 흉부음 데이터 검출)

  • 임선희;박기영;최규훈;박강서;김종교
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2156-2159
    • /
    • 2003
  • Thoracic sound has been widely known as a good method to examine thoracic disease. But, it's difficult to diagnose with correct data according to patient's thoracic position from same patient who has thoracic disease. Therefore, it is necessary to normalize the data for lung sound objectively In this paper, we'd like to detect a useful data for medical examination by applying PCA(Principal Component Analysis) to thoracic sound data and then present a objective data about lung and heart sound for thoracic disease.

  • PDF