• Title/Summary/Keyword: heart arrest

Search Result 208, Processing Time 0.032 seconds

Chest compression efficiency for three methods of single-person rescuer infant cardiopulmonary resuscitation (1인 구조자 영아심폐소생술시 세 가지 가슴압박 방법의 가슴압박 효율성 비교 : 해양경찰교육원 신임경찰 교육생 대상으로)

  • Hwang, Soon-Jung;Yun, Jong-Geun;Kim, Jung Sun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.24 no.3
    • /
    • pp.107-116
    • /
    • 2020
  • Purpose: We compared three chest compression methods to find an efficient method for performing infant cardiopulmonary resuscitation (CPR) for single rescuers and improving chest compressions quality. Methods: Thirty new marine police trainees at the Korea Coast Guard Education Institute were tested for five sessions using three methods of single rescuer infant CPR: two-finger chest compression, two-thumb encircling chest compression, and two-finger support chest compression. Results: The depth, accuracy, and number of compressions per minute of resuscitation were analyzed for the above three methods. The depth of two-finger chest compression, two-thumb encircling chest compression, and two-finger support chest compression was 3.53±0.20cm, 4.10±0.13cm, and 4.22±0.15cm, respectively. Accuracy was 23.86±12.59%, 54.11±10.8%, 71.55±18.81%, respectively, while the time for one cycle of 30 chest compression was 16.01±10.5 seconds, 16.45±0.85 seconds, and 16.56±0.91 seconds, respectively. Chest compression interruptions were 6.59±0.78 seconds, 7.17±0.37 seconds, and 6.97±0.35 seconds, respectively. The interruptions were consistent with the range of 5-10 seconds suggested by the American Heart Association. Conclusion: When one rescuer performs CPR for an infant in cardiac arrest, a comparative analysis of three methods showed that two-thumb encircling chest compression is the best for accuracy and efficiency of chest compressions.

Influence of Cerebral Protection Methods in Thoracic Aortic Surgery Using Hypothermic Circulatory Arrest (저체온 순환정지를 이용한 흉부 대동맥 수술 시 뇌관류 방법에 따른 수술결과)

  • Kim, Jae-Hyun;Na, Chan-Young;Oh, Sam-Sae
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.229-238
    • /
    • 2008
  • Background: Protection of the brain is a major concern during thoracic aortic surgery using hypothermic circulatory arrest (HCA). This study compares the surgical outcomes of two different cerebral protection methods in thoracic aortic surgery using HCA: retrograde cerebral protection (RCP) and antegrade cerebral protection (ACP). Material and Method: We retrospectively reviewed data on 146 patients who underwent thoracic aortic surgery from May 1995 to February 2007 using either RCP (114 patients, Group 1) or ACP (32 patients, Group 2) during HCA. There were 104 dissections (94 acute and 10 chronic) and 42 aneurysms (41 true aneurysms and 1 pseudoaneurysm), and all patients underwent ascending aortic replacement. There were 33 cases of hemiarch replacement, 5 of partial arch replacement, and 21 of total arch replacement. Result: The two groups were similar in preoperative and operative characteristics, but Group 2 had more elderly (over 70 years old) patients (34.4% vs. 10.5%), more coronary artery diseases (18.8% vs. 4.4%), more total arch replacements (46.9% vs. 5.3%) and longer HCA time ($50{\pm}24$ minutes vs. $32{\pm}17$ minutes) than Group 1. The operative mortality was 4.4% (5/114) and 3.1% (1/32), the incidence of permanent neurologic deficits was 5.3% (6/114) and 3.1% (1/32), and the incidence of temporary neurologic deficits was 1.8% (2/114) and 9.4% (3/32) in Groups 1 and 2, respectively. There were no statistical differences between the two groups in operative mortality, postoperative bleeding, or neurologic deficits (permanent and temporary). Conclusion: The early outcomes of aortic surgery using HCA were favorable and showed no statistical difference between RCP and ACP. However, the ACP patients endured longer HCA times and more extended arch surgeries. ACP is the preferred brain protection technique when longer HCA time is expected or extended arch replacement is needed.

Implantable cardioverter defibrillator therapy in pediatric and congenital heart disease patients: a single tertiary center experience in Korea

  • Jin, Bo Kyung;Bang, Ji Seok;Choi, Eun Young;Kim, Gi Beom;Kwon, Bo Sang;Bae, Eun Jung;Noh, Chung Il;Choi, Jung Yun;Kim, Woong Han
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.125-129
    • /
    • 2013
  • Purpose: The use of implantable cardioverter defibrillators (ICDs) to prevent sudden cardiac death is increasing in children and adolescents. This study investigated the use of ICDs in children with congenital heart disease. Methods: This retrospective study was conducted on the clinical characteristics and effectiveness of ICD implantation at the department of pediatrics of a single tertiary center between 2007 and 2011. Results: Fifteen patients underwent ICD implantation. Their mean age at the time of implantation was $14.5{\pm}5.4$ years (range, 2 to 22 years). The follow-up duration was $28.9{\pm}20.4$ months. The cause of ICD implantation was cardiac arrest in 7, sustained ventricular tachycardia in 6, and syncope in 2 patients. The underlying disorders were as follows: ionic channelopathy in 6 patients (long QT type 3 in 4, catecholaminergic polymorphic ventricular tachycardia [CPVT] in 1, and J wave syndrome in 1), cardiomyopathy in 5 patients, and postoperative congenital heart disease in 4 patients. ICD coils were implanted in the pericardial space in 2 children (ages 2 and 6 years). Five patients received appropriate ICD shock therapy, and 2 patients received inappropriate shocks due to supraventricular tachycardia. During follow-up, 2 patients required lead dysfunction-related revision. One patient with CPVT suffered from an ICD storm that was resolved using sympathetic denervation surgery. Conclusion: The overall ICD outcome was acceptable in most pediatric patients. Early diagnosis and timely ICD implantation are recommended for preventing sudden death in high-risk children and patients with congenital heart disease.

Clinical Study and Risk Factors of Surgical Mortality of Congenital Heart Defects (선천성 심장기형의 임상고찰 및 수술사망율에 미치는 위험인자의 분석)

  • 이상호;김병균
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.17-26
    • /
    • 1997
  • Objeitives. The surgical mortality of congenital heart defects has been reduced (or the very young age group. Especially, young age at repair is an important risk factor for mortality after repair of tetralogy of Falloff. Some risk factors were analyzed Methods. Three hundred and sixty six patients underwent surgical Intervention. Ages ranged from 5 days to 64 years, and 80 patients were adults(over 15 years of age). The defects consisted of 313(84.2%) acyanotic and 53(15.8%) cyanotic anomalies. The surgical mortalities were evaluated by univariate and multivariate analysis. Results. The overall surgical mortality was 10.4%. Mos deaths occurred in the infant group younger than 6 months(20/38 deaths) and in cyanotic group(21/38 deaths). Surgical infant mortality younger than 12 months was 24.8%(25/101). Risk factors of mortality in open heart surgery were age(p< 0.0001), body weight(p< 0.0001), pump time(p< 0.0001), aortic cross clamp time(p< 0.0001), use of total circulatory arrest(p<0.0001) and cyanotic disease(p<0.0001) by univariate analysis. But by multivariate analysis, the risk factor of mortality in open heart surgery was disease entity(p=0.002) only. A disease group with the highest risk was a cyanotic group(odds ratio was 15.3 relative to ventricular septal defect) excluding tetralogy of Falloff(odds ratio=0.27). Conclusions. Even though the most important risk factor was disease entity, we should conentrate our efforts on the technically improvable factors affecting surgical mortality indicated by univarlate analysis.

  • PDF

The Clinical Experience of The Descending Thoracic and Thoracoabdominal Aortic Surgery (하행대동맥 및 흉복부 대동맥 수술의 임상적 경험)

  • 조광조;우종수;성시찬;최필조
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.584-589
    • /
    • 2002
  • Background : The thoracic and thoracoabdominal aortic surgery is a complicated procedure that has various method of approach and protection. The authors have performed several methods to treat these diseases. Therefore, we attempt to analyze their results and risks. Material and Method: From June of 1992 to August of 2001, we performed 26 cases of thoracic aortic surgery and 10 cases of thoracoabdominal aortic surgery. There were 17 aortic dissections, 17 aortic aneurysms, one coarctation of aorta and one traumatic aortic aneurysm. The thoracic aortic replacement was performed under a femorofemoral bypass, an LA to femoral bypass, or a deep hypothermic circulatory arrest. The thoracoabdominal aortic replacement was performed under a femorofemoral bypass or a pump assisted rapid infusion. Result: There were 7 renal failures, 11 hepatopathies, 7 cerebral vascular accidents, 2 heart failures, 5 respiratory insufficiencies, and 2 sepsis in postoperative period. There were 9 hospital mortalities which were from 2 bleedings, 2 heart failures, 2 renal failures, a sepsis, a respiratory failure, and a cerebral infarction. There were 3 late deaths which were from ruptured distal anastomosis, cerebral infarction, and pneumonia. Conclusion: Deep hypothermic circulatory arrest was not good supportive methods for thoracic aortic replacement. Total thoracoabdominal aortic replacement was a high risk operation.

A study on Supply Extension Device of AED (AED의 보급 확대 방안에 관한 연구)

  • Koh, Jae-Moon;Kim, Young-Ho;Han, Sang-Hak
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.147-168
    • /
    • 2005
  • It examined the doubt point which AED motive relates until now, the AED should have bought a life how, present address of our country site pre-hospital care, comparison it tried to observe the advanced nation instance back. Gist of this research the AED important cold region once compared to informed to how many cardiac arrest patient, against him the what kind of preparation wanted informing the necessary cold region. It soaks simultaneously but the AED motive is widely supplied distant in future and it is generality and it is feeble but it wanted doing one morning. The habit difference of an American who does of course meat diet mainly and a Korean is many and it compares in the United States and the cardiac arrest patient comparison occurs holds a point few. To become Western anger but and be caused by with thin dietary life, stanching bleeding cung, with the fact that the heart attack is increasing rapidly with the hyperextension. It is a talk which anyone it knows all. The major league most Choi huy Sub in condition will catch the ball which floats and the multi co-player and to collide when falling down, the medical device which is committed with emergency aid is AED motive. From the United States subway station and the shopping which are a public place on the baseball field outside the jar which it will drive, the museum and the school, easily there is it will be able to discover the AED from the court of justice back. The Pittsburg university the students per the individual $30 the core phyey were receiving the smallness lifestyle alcoholic beverage and a AED motive actual training with mercy of degree. From the United States distant in future the AED motive is sold even from the retail store and. From our country like this plan government offices temporary disposal education from from 119 fire fighters emergency structure company in fire fighting government employee and nursing must magnify a former enterprise rainy spell in summer multi temporary disposal education with the head which it will burn with the head. This plan in early rising will be able to become fixed in Korea it forecasts with the fact that. The research which it sees it leads and like the United States to some day become fixed even from our country to believe and suspicion it is not and in the people in approach ease one AED supply plan fire fighting government employees stand in the first and feed with the fact that must be positive at this enterprise they become.

  • PDF

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

The status of advanced cardiac life support performance by resident belonging to other department except for department of emergency medicine in in-hospital cardiac arrest (병원 내 심정지 상황에서 응급의학과 이외 전공의에 의해 시행된 전문 심장소생술의 현황)

  • Cho, Hyun-Woo;Woo, Jae-Hyug;Lim, Yong-Su;Jang, Jae-Ho;Cho, Jin-Seong;Choi, Jea-Yeon;Yang, Hyuk-Jun;Hyun, Sung-Youl
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.485-492
    • /
    • 2018
  • Objective: This paper reports the status of the advanced cardiac life support (ACLS) according to the guidelines by residents belonging to other departments other than the department of emergency medicine. The differences in status between the junior group and senior group was also investigated according to grades of residents. Methods: The ACLS performance for in-hospital cardiac arrest cases of one academic hospital, except for the cases occurring in intensive care unit between November 2015 and October 2017, were analyzed retrospectively. Data included the characteristics of residents, patients' outcomes, ACLS performance, and conventional treatment having discordance with the ACLS guidelines. Leaders during cardiopulmonary resuscitation (CPR) were divided into a junior group and senior group. Results: A total of 152 cases were enrolled in this study. Of these, 131 cases (86.2%) showed at least one treatment with inconsistency from the guidelines and the incidence of discordant treatment was similar in the two groups (55 [85.9%] vs. 76 [88.4%], P=0.657). Implicit use of sodium bicarbonate was more frequent in the senior residents group (odds ratio [OR], 3.04; 95% confidence interval [CI], 1.36-6.81). On the other hand, no use of a defibrillator was less frequent in the senior residents group (OR, 0.14; 95% CI, 0.03-0.81). Conclusion: In both groups, the rate of discordance with the ACLS guidelines during CPR were high. The rate of implicit use of sodium bicarbonate and no use of defibrillator were significantly different in the two groups. A customized education strategy for ACLS is needed for each group.

Risk Factor Analysis for Operative Death and Brain Injury after Surgery of Stanford Type A Aortic Dissection (스탠포드 A형 대동맥 박리증 수술 후 수술 사망과 뇌손상의 위험인자 분석)

  • Kim Jae-Hyun;Oh Sam-Sae;Lee Chang-Ha;Baek Man-Jong;Hwang Seong-Wook;Lee Cheul;Lim Hong-Gook;Na Chan-Young
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.289-297
    • /
    • 2006
  • Background: Surgery for Stanford type A aortic dissection shows a high operative mortality rate and frequent postoperative brain injury. This study was designed to find out the risk factors leading to operative mortality and brain injury after surgical repair in patients with type A aortic dissection. Material and Method: One hundred and eleven patients with type A aortic dissection who underwent surgical repair between February, 1995 and January 2005 were reviewed retrospectively. There were 99 acute dissections and 12 chronic dissections. Univariate and multivariate analysis were performed to identify risk factors of operative mortality and brain injury. Resuit: Hospital mortality occurred in 6 patients (5.4%). Permanent neurologic deficit occurred in 8 patients (7.2%) and transient neurologic deficit in 4 (3.6%). Overall 1, 5, 7 year survival rate was 94.4, 86.3, and 81.5%, respectively. Univariate analysis revealed 4 risk factors to be statistically significant as predictors of mortality: previous chronic type III dissection, emergency operation, intimal tear in aortic arch, and deep hypothemic circulatory arrest (DHCA) for more than 45 minutes. Multivariate analysis revealed previous chronic type III aortic dissection (odds ratio (OR) 52.2), and DHCA for more than 45 minutes (OR 12.0) as risk factors of operative mortality. Pathological obesity (OR 12.9) and total arch replacement (OR 8.5) were statistically significant risk factors of brain injury in multivariate analysis. Conclusion: The result of surgical repair for Stanford type A aortic dissection was good when we took into account the mortality rate, the incidence of neurologic injury, and the long-term survival rate. Surgery of type A aortic dissection in patients with a history of chronic type III dissection may increase the risk of operative mortality. Special care should be taken and efforts to reduce the hypothermic circulatory arrest time should alway: be kept in mind. Surgeons who are planning to operate on patients with pathological obesity, or total arch replacement should be seriously consider for there is a higher risk of brain injury.

Congenital Aortic Valvular Stenosis: report of a case (선천성 대동맥판막 협착증 치험 1례)

  • 김병열
    • Journal of Chest Surgery
    • /
    • v.12 no.4
    • /
    • pp.350-354
    • /
    • 1979
  • The incidence of congenital aortic valvular stenosis has been known rare, and approximately 3-6% of congenital heart diseases. Recently, we experienced 1 case of congenital aortic valvular stenosis, and which was corrected surgically under extracorporeal circulation successfully. A 11 years old male pt. was admitted to N.M.C. because of dyspnea, dizziness, chest pain and episode of syncope. An auscultation, harsh systolic murmur [Gr. IV/VI] was noted at aortic area and also palpable strong thrill. ECG showed LVH c strain pattern and suspicious LVH finding in simple chest P-A film. In Lt. cardiac catheterization, abrupt pressure change [110mmHg] between LV & Aorta was noted across the aortic valve. And aortic insufficiency was absent, well visualized both coronary arteries and suspicious bicuspid aortic valve in aortography. Valve form was bicuspid, large one was noncoronary cusp and another cusp was Rt. & Lt. coronary cusp which was interpositioned rudimentary commissure. Central aortic orifice was about 5ram in diameter. Valvulotomy was done along the fusioned commissure between noncoronary cusp and Rt. & Lt.coronary cusp, and then short incision was added between Rt. coronary cusp & Lt. coronary cusp. Immediate postoperative course smooth but unknown cardiac arrest was noted in POD second day. Complete recovery was done without sequelae by resuscitation. After operation, clinical symptoms were subsided but systolic murmur [Gr. II/VI] was audible at aortic area, diastolic murmur was absent. ECG showed still remained LVH but much decreased R wave voltage in Lt. precordial leads. Simple chest P-A showed no interval changes compared to preop film. Control Lt. heart catheterization revealed still remained pressure gradient [40ramrig] between LV & Aorta. But much decreased pressure gradient compared to preop pressure gradient [110mmHg].

  • PDF