• Title/Summary/Keyword: health-risk

Search Result 8,978, Processing Time 0.053 seconds

The efficacy and safety of transcatheter closure of atrial septal defect with Amplatzer septal occluder in young children less than 3 years of age (3세 미만 심방중격결손 소아에서 Amplatzer 기구 폐쇄술의 안전성 및 효용성)

  • Lee, Soo Hyun;Choi, Deok Young;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.494-498
    • /
    • 2009
  • Purpose : Applicability of transcatheter closure of atrial septal defect (ASD) has been expanded by accumulation of clinical experiences and evolutions of the device. This study was performed to evaluate the safety and efficacy of transcatheter closure of ASD with Amplatzer septal occluder (ASO) in young children less than 3 years of age. Methods : From May 2003 to December 2005, 295 patients underwent transcatheter closure of ASD with ASO in the Severance Cardiovascular Hospital, Yonsei University Health System. Among them, 51 patients less than 3 years of age were enrolled in this study. We investigated procedural success rate, rate of residual shunt, frequency of complications, procedure/fluoroscopy time, and need of modified techniques for device implantation. Results : The median age was 2.1 years and median body weight was 12 kg. Implantation of device was successful in 50 patients (98%). Seven patients (15%) showed a small residual shunt 1 day after the procedure, but complete occlusion had been documented at 6 month follow-up in all patients (100%). The pulmonary to systemic flow ratio (Qp/Qs), peak systolic pulmonary artery pressure, and peak systolic right ventricular pressure had decreased significantly after closure of ASD. There were 2 complications including device embolization (1, 2%) and temporary groin hematoma (1, 2%). Conclusion : Transcatheter closure of ASD with ASO can be performed with satisfactory results and acceptable risk even in young children less than 3 years of age. We could suggest that even in very young children with ASD, there is no need to wait until they grow to a sufficient size for the transcatheter closure.

Pulse wave velocity and ankle brachial index in normal adolescents (정상 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구)

  • Kim, Ji Hye;Gil, Tae Young;Lee, Hee Woo;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.6
    • /
    • pp.549-555
    • /
    • 2007
  • Purpose : Pulse wave velocity (PWV) and ankle brachial index (ABI) are simple, non-invasive methods to assess arterial stiffness. These parameters are also known to be closely related to cardiovascular risk factors and diseases. The purposes of this study were to measure blood pressure, PWV, ABI in healthy Korean adolescents, set up their normal values and assess their correlations. Methods : Three hundred ninety two healthy adolescents (213 boys and 179 girls) underwent measurement of brachial ankle pulse wave velocity (baPWV), ABI, body mass index(BMI) and blood pressure from four extremities. Linear regression analysis was performed to reveal the correlations between PWV, ABI and independent variables. Results : Blood pressure and PWV were significantly higher in all extremities in males compared to females. Blood pressure of both brachial and ankle showed positive correlation with body weight, height, and BMI, whereas ABI showed no correlation with any of these indices. Conclusion : Blood pressure increases as body weight, height and BMI increases. PWV shows positive correlation with blood pressure. It will be helpful to predict the risks of cardiovascular diseases in adolescents.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Effect of Pine (Pinus densiflora) Needle Extracts on Synthesis of Collagen in Osteoblastic MC3T3-E1 Cells (적송잎 추출물이 조골세포의 collagen 합성에 미치는 영향)

  • Jeon, Min-Hee;Kim, Young-Kyoung;Park, Yong-Soo;Hwang, Hyun-Jung;Kim, Sung-Gu;Lee, Sang-Hyeon;Choi, In-Soon;Kim, Mi-Hyang
    • Journal of Life Science
    • /
    • v.20 no.4
    • /
    • pp.607-613
    • /
    • 2010
  • Osteoporosis is a disease involving a decrease in bone mineral density and an increased risk of fractures. The MC3T3-E1 pre-osteoblastic cell line is a well-accepted model of osteogenesis in vitro. Pine needles have long been used as a traditional health-promoting medicinal food in Korea. In this study, MTT assay, the alkaline phosphatase (ALP) activity and collagen synthesis of osteoblast cells were investigated to determine the effects of pine needle extracts on cell proliferation and differentiation. Pine needle extracts were prepared using hexane, ethanol and water. The effects of the pine needle extracts were examined by comparing the results with those of commercial agents, such as proanthocyanidin. The MC3T3-E1 cells exposed to proanthocyanidin showed increased proliferation in a concentration-dependent manner. The cells exposed to the hexane extract showed a similar increase in proliferation to that observed with proanthocyanidin. The hexane extract showed the highest ALP activity. Moreover, a supplement of pine needle extracts induced collagen synthesis in MC3T3-E1 cells. The pine needle extract produced the highest level of collagen synthesis at concentrations of $10{\sim}50\;{\mu}g/ml$. These results indicate that pine needle extracts have an anabolic effect on bone by promoting osteoblastic differentiation, and may be used in the treatment of common metabolic bone diseases.

The Actual Management State of Trial Contact Lenses and Lens Care Products in Local Optical Shops (안경원의 시험착용 콘택트렌즈 및 관리용품 관리 실태)

  • Park, Mijung;Lee, Unjung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.391-401
    • /
    • 2011
  • Purpose: In the present study, the actual management state of trial contact lenses and lens care products in local optical shops was surveyed and analyzed to reduce the risk of lens complication possibly induced by neglecting lens care. Methods: The feeling of contact lens wearers during the wear of trial contact lenses was surveyed. Futhermore, the actual management state of trial contact lenses such as cosmetic lens and RGP lens and lens care products was also investigated by surveying opticians who trade contact lenses in local optical shops. Results: It was found that consumers trusted the sanitary conditions of the lens since trial cosmetic contact lens and RGP lens were cleaned before and after trails by over 98% of opticians in local optical shops. For trial cosmetic lens, cleaning with normal saline, multipurpose solution for soft lens and combination of saline and multipurpose solution were 38.5%, 40.5% and 21%, respectively, before trials. After trials, cosmetic lenses were cleaned with normal saline, multipurpose solution for soft lens and a combination of saline and multipurpose solution were 13%, 75%, and 12%, respectively. On the other hand, cleaning with normal saline, multipurpose solution for RGP lens and combination of saline and multipurpose solution were 28.5%, 38.5% and 33%, respectively, before trying trial RGP lens. After trials, RGP lenses were cleaned with normal saline, multipurpose solution for RGP lens and a combination of saline and multipurpose solution were 2.5%, 70%, and 27.5%, respectively, indicating that relatively many opticians followed the lens cleaning regimen. In local optical shops, the cleaning trial cosmetic lens was mainly conducted at every 10 days or a month and the washing cycle of cosmetic lens case was in a month or 2~3 months. The cleaning interval of trial RGP lens was primarily in a month or 2~3 months. For those lens cases, more than 75% of opticians washed them with a surfactant and then rinsed with cold water. The storing periods of lens care products were primarily in a week for saline and in a month and 2~3 months indicating that storing period of lens care products was relatively well-kept in local optical shops. Conclusions: It is thought that the concern about any microbial infection is not that high since trial contact lenses and lens care products were generally well-managed by opticians in local optical shops from the results above. However, better public eye health and better public confidence in opticians may be possible if further strengthen in avoidance of lens cleaning with saline, keep of cleaning cycles within 2 weeks and rinsing of lens cases with hot water happens.

Development of QSAR Model Based on the Key Molecular Descriptors Selection and Computational Toxicology for Prediction of Toxicity of PCBs (PCBs 독성 예측을 위한 주요 분자표현자 선택 기법 및 계산독성학 기반 QSAR 모델 개발)

  • Kim, Dongwoo;Lee, Seungchel;Kim, Minjeong;Lee, Eunji;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.621-629
    • /
    • 2016
  • Recently, the researches on quantitative structure activity relationship (QSAR) for describing toxicities or activities of chemicals based on chemical structural characteristics have been widely carried out in order to estimate the toxicity of chemicals in multiuse facilities. Because the toxicity of chemicals are explained by various kinds of molecular descriptors, an important step for QSAR model development is how to select significant molecular descriptors. This research proposes a statistical selection of significant molecular descriptors and a new QSAR model based on partial least square (PLS). The proposed QSAR model is applied to estimate the logarithm of partition coefficients (log P) of 130 polychlorinated biphenyls (PCBs) and lethal concentration ($LC_{50}$) of 14 PCBs, where the prediction accuracies of the proposed QSAR model are compared to a conventional QSAR model provided by OECD QSAR toolbox. For the selection of significant molecular descriptors that have high correlation with molecular descriptors and activity information of the chemicals of interest, correlation coefficient (r) and variable importance of projection (VIP) are applied and then PLS model of the selected molecular descriptors and activity information is used to predict toxicities and activity information of chemicals. In the prediction results of coefficient of regression ($R^2$) and prediction residual error sum of square (PRESS), the proposed QSAR model showed improved prediction performances of log P and $LC_{50}$ by 26% and 91% than the conventional QSAR model, respectively. The proposed QSAR method based on computational toxicology can improve the prediction performance of the toxicities and the activity information of chemicals, which can contribute to the health and environmental risk assessment of toxic chemicals.

Radioactivation Analysis of Concrete Shielding Wall of Cyclotron Room Using Monte Carlo Simulation (PET 사이클로트론 가동에 따른 콘크리트 차폐벽의 방사화)

  • Jang, Donggun;Lee, Dongyeon;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.335-341
    • /
    • 2017
  • Cyclotron is a device that accelerates positrons or neutrons, and is used as a facility for making radioactive drugs having short half-lives. Such radioactive drugs are used for positron emission tomography (PET), which is a medical apparatus. In order to make radioactive drugs from a cyclotron, a nuclear reaction must occur between accelerated positrons and a target. After the reaction, unncessary neutrons are produced. In the present study, radioactivation generated from the collisions between the concrete shielding wall and the positrons and neutrons produced from the cyclotron is investigated. We tracked radioactivated radioactive isotopes by conducting experiments using FLUKA, a type of Monte Carlo simulation. The properties of the concrete shielding wall were comparatively analyzed using materials containing impurities at ppm level and materials that do not contain impurities. The generated radioactivated nuclear species were comparatively analyzed based on the exposure dose affecting human body as a criterion, through RESRAD-Build. The results of experiments showed that the material containing impurities produced a total of 14 radioactive isotopes, and $^{60}Co$(72.50%), $^{134}Cs$(16.75%), $^{54}Mn$(5.60%), $^{152}Eu$(4.08%), $^{154}Eu$(1.07%) accounted for 99.9% of the total dose according to the analysis having the exposure dose affecting human body as criterion. The $^{60}Co$ nuclear species showed the greatest risk of radiation exposure. The material that did not contain impurities produced a total of five nuclear species. Among the five nuclear species, 54Mn accounted for 99.9% of the exposure dose. There is a possibility that Cobalt can be generated by inducive nuclear reaction of positrons through the radioactivation process of $^{56}Fe$ instead of impurities. However, there was no radioactivation because only few positrons reached the concrete wall. The results of comparative analysis on exposure dose with respect to the presence of impurities indicated that the presence of impurities caused approximately 98% higher exposure dose. From this result, the main cause of radioactivation was identified as the small ppm-level amount of impurities.

Fate Analysis and Impact Assessment for Vehicle Polycyclic Aromatic Hydrocarbons (PAHs) Emitted from Metropolitan City Using Multimedia Fugacity Model (다매체거동모델을 이용한 대도시 자동차 배출 Polycyclic Aromatic Hydrocarbons (PAHs) 거동 해석 및 영향평가)

  • Rhee, Gahee;Hwangbo, Soonho;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.479-495
    • /
    • 2018
  • This study was carried out to research the multimedia fate modeling, concentration distribution and impact assessment of polycyclic aromatic hydrocarbons (PAHs) emitted from automobiles, which are known as carcinogenic and mutation chemicals. The amount of emissions of PAHs was determined based on the census data of automobiles at a target S-city and emission factors of PAHs, where multimedia fugacity modeling was conducted by the restriction of PAHs transfer between air-soil at the impervious area. PAHs' Concentrations and their distributions at several environmental media were predicted by multimedia fugacity model (level III). The residual amounts and the distributions of PAHs through mass transfer of PAHs between environment media were used to assess the health risk of PAHs at unsteady state (level IV), where the sensitivity analyses of the model parameter of each variable were conducted based on Monte Carlo simulation. The experimental result at S-city showed that Fluoranthene among PAHs substances are the highest residual concentrations (60%, 53%, 32% and 34%) at all mediums (atmospheric, water, soil, sediment), respectively, where most of the PAHs were highly accumulated in the sediment media (more than 80%). A result of PAHs concentration changes in S-city over the past 34 years identified that PAHs emissions from all environmental media increased from 1983 to 2005 and decreased until 2016, where the emission of heavy-duty vehicle including truck revealed the largest contribution to the automotive emissions of PAHs at all environment media. The PAHs concentrations in soil and water for the last 34 years showed the less value than the legal standards of PAHs, but the PAHs in air exceeded the air quality standards from 1996 to 2016. The result of this study is expected to contribute the effective management and monitoring of toxic chemicals of PAHs at various environment media of Metropolitan city.

Comparison of the Legislation Applicable to Compare the use of Diagnostic Radiation Devices (진단용 방사선발생장치 이용에 적용되는 법제의 비교)

  • Ko, Jong-Kyung;Jeon, Yeo-Ryeong;Han, Eun-Ok;Cho, Pyong-Kon;Kim, Yong-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.277-286
    • /
    • 2015
  • Diagnostic radiation devices that is used in the country has reached to 78,000 units. When used for human subjects diagnostic purposes, it is subject to Medical Service Act, when used in diagnostic purposes in animal subjects, the subject to Veterinarians Act. When used for other purposes are subject to the Nuclear Safety Act. Even the same radiation devices varies the legislation that is applied depending on the intended use and object. Diversified been p rovisions a re necessary compared to t he analysis o f l egal content in o rder t o prevent confusion of the legislation is a matter to be applied. It is a qualitative study that Nuclear Safety Act, Medical Service Act and Veterinarians Act administrative procedures for the introduction of the applied diagnostic radiation devices, safety inspection, human resources management, area management and the content related to administrative punishment. The Nuclear Safety Act sub-provisions, the introduction of diagnostic radiation generating devices, there are many complex and complete requirements administrative procedures on the concept of a permit. Inspection of safety associated with the use, would be subject to periodic inspection auditing characteristics over the entire field of radiation safety management. It must receive court regular education for the safety administrator and workers. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Unlike the reference of the radiation dose rate to specify the radiation controlled area there is a measurement obligation of radiation dose rate. Quantitative difference of administrative punishment that is imposed when legislation violation has reached up to 10 times, over the entire field, the largest burden of radiation safety management at the time of application of the Nuclear Safety Act sub provisions. And it is applied differently depending on the purpose and the imaging target using the same diagnostic radiation devices. Depending on the use mainly under the current legal system, radiation can be lacking in fairness of the contents of the legislation for safety management, there is a risk of confusion. Alternatives such as centralized and standardization of legislation by diagnostic radiation devices use is expected to be necessary.

tans-Resveratrol Content of Varieties and Growth Period in Peanut (땅콩 품종 및 생육기별 trans-Resveratrol 함량)

  • Lee, Mi-Ja;Cheong, Young-Keun;Kim, Hyung-Soon;Park, Ki-Hun;Doo, Hong-Soo;Suh, Duck-Yong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.48 no.6
    • /
    • pp.429-433
    • /
    • 2003
  • trans-Resveratrol(3,5,4'-trihydroxystilbene) is phenolic compound present in grapes, wines, and peanuts, has been reported to have health benefits including anticarcinogenic effects, protection against cardiovascular diseases and reduced cancer risk. A simple method for the quantitative extraction of trans-resveratrol from peanut has been developed. Optimal conditions for extraction were investigated. Type of solvent, time, and temperature assayed influenced trans-resveratrol yield. Adequate extraction condition was decided to ethanol/water (80:20v/v) maintained at $25^{\circ}C$ for 45 min. After extraction, the protocol consists of sample preparation using a $\textrm{C}_{18}$ solid-phase extraction (SPE) cartridge after concentrate with rotary evaporator and quantified by reversed phase HPLC using a $\textrm{C}_{18}$ column at 308 nm. Analytical methods for measuring trans-resveratrol in peanut were adapted to isolate, identify, and quantify trans-resveratrol in 11 peanut varieties by HPLC (high-performance liquid chromatography) with UV detector, The 11 peanut varieties content ranged from 0.018 to 1.125 $\mu\textrm{g}/\textrm{g}$ with an average of 0.289 $\mu\textrm{g}/\textrm{g}$. The contents were higher in the seeds with than without testa, regardless of varieties. The trans-resveratrol content was Higher in 110, 130 days after sowing than that of other period.