• Title/Summary/Keyword: headloss

Search Result 16, Processing Time 0.02 seconds

The adaptive filter configuration for down stream of Naktong river (낙동강 하류원수에 적합한 여과지의 여재구성)

  • 김상구;류동춘
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.481-488
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2~3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

  • PDF

The Effects of Anthracite Media Sphericity on Filtration Efficiency (안쓰라사이트 여재 원형도가 여과 효율에 미치는 영향)

  • Cheong, Won-suk;Choi, Suing-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.763-770
    • /
    • 2007
  • There are many design parameters affecting filtration efficiency such as filteration rate, media packing depth, size distribution, and so on. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media. The effect of sphericity on the performance of anthracite filter has been investigated. Media from eight water treatment plants have been collected. The sphericity of each media has been calculated by using well known headloss equations such as Kozeny equation, Dahmarajah equation etc.. Columns packed with anthracite media having different sphericity have been used to compare headloss development, floc accumulation in the bed, particles in bed water, filtrate turbidities after backwash and so on. The repeated experiments have indicated that the sphericity of anthracite media may not have remarkable influence on the filter performance as it has been suspected. It also has been prospected in the experiment that the media of higher sphericity would store more particles in the bed and give better filtrate quality, if provided that the effective size and the size distribution of media would be the same.

The adaptive filter configuration for down stream of Naktong river (낙동강 하류원수에 적합한 여과지의 여재구성)

  • Kim, Sang-goo;Ryou, Dong-choon;Lee, Yung-sik;Son, Jin-eun
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.95-95
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2∼3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

A study on the headloss of filter media for treatment of Road Runoff (도로노면 유출수 처리를 위한 여과에서의 여재별 손실수두 특성)

  • Choi, Weon-Suk;Song, Changsoo;Kim, Seog-ku
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.697-704
    • /
    • 2008
  • Stormwater runoff from urban road area as non-point source has a tendency of including lots of pollutants at initial rain period. Recently, there are several cases of having installed treatment facilities for reducing pollution discharge from the impervious cover in urban area to prevent watershed environment from getting worse. The filtration type among non-point source treatment systems has been known as one of the most efficient system for treatment of non-point source pollutants. Therefore, various kinds of filter media such as expanded polypropylene(EPP), granular activated carbon, zeolite, perlite, illite, sand, gravel has been developed. This study was conducted to verify performance and hydraulic characteristics of filter media as measures for non-point source. The experiment was carried out to evaluate applicability and variation of 4 kind of most popular filter media(EPP, GAC, Zeolite, Perlite) in headloss with elapsed time and influent flow rate and to obtain data base that could be used to establish management plan for road runoff treatment. In experiment by tap water, it showed that EPP and perlite those are floatable materials showed stable operating performance and lower headloss than the others.

Odor Removal by Using Compost and Granular Scrap Tires (퇴비 및 폐타이어 Granule을 이용한 악취 제거)

  • Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.43-50
    • /
    • 1999
  • In spite of low energy requirement, and operation and construction cost, biofilters with soil beds have not been operated efficiently. Because of excess moisture in winter and rainy periods, saturated pores in the bed prevent passage and sorption of odorous compounds. Sometimes this results in septic conditions that release previously sorbed and oxidized sulfur. Therefore, an economical and effective alternative needs to be developed. The objectives of this study were to confirm applicability of the granular scrap tires with compost for treating odorous gas as well as to obtain optimum design parameters for proposed system. In lab-scaled test, multiple stage reactors had lower headloss than a single stage reactor and less headloss was occurred for the gas with higher moisture content. For practical purpose, pilot-scaled reactor was operated to remove odor from septic tank, manure and animal wastewater treatment plant and composting machine. According to the results of pilot scaled test, $H_2S$ can be always removed completely and ammonia/amine can be removed excellently when proper moisture content is provided. The results from lab and pilot test showed that granular scrap tire could be replaced with soil as supporting material for biofilter showed excellent drainage because of its ability to reject moisture.

  • PDF

An investigation into the performance of a high-speed synthetic fiber filter employing different types of coagulants (응집제에 따른 합성섬유 여재를 충진한 고속필터의 여과특성에 관한 연구)

  • Park, Kisoo;Kim, Youngchul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.125-139
    • /
    • 2017
  • In this paper, the performance of a synthetic fiber filter aimed at high-speed operation and dosed with different coagulants or filter aids was investigated. Without a coagulant, the filter efficiency was about 62% which was greatly enhanced when three types of coagulants namely PAC, Alum, and $FeCl_3$ were used. Among the coagulants tested, PAC was the most effective, giving 91% filter efficiency, followed by Alum with 90%, and $FeCl_3$ with 78%. PAC worked effectively at a very small range of dose, but Alum was relatively effective in a wide range of concentration. Compared with PAC and Alum, $FeCl_3$ provided more or less contant efficiency regardless of its dose but gave the poorest filter efficiency. Moreover, as the inflow turbidity increased, headloss increased and the efficiency decreased at any dose and type of coagulant. The headloss recorded in this particular synthetic fiber filter is not significant as compared to that observed in typical granular filters. The recovery of solids estimated after filter cleaning was about 80% for both PAC and Alum, but poorer at 72% in the case of $FeCl_3$ due to the heavy and large floc characteristics. The recurrence of filter efficiency verified through repetitive filter runs was found to be satisfactory.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

An experimental study on the filtration test of cotton ball filters (코튼볼 여재의 여과 특성 실험 연구)

  • Kim, Sunghong;Kim, Heejun;Kim, Donghan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.79-86
    • /
    • 2019
  • In order to measure the filtration characteristics of a cotton ball shape filter, the experiments of suspended solids(SS) surrogate material selection and filtration performance have been carried out in this study. Between the two materials of powdered activated carbon(PAC) and powdered red-clay, PAC is more suitable surrogate material in terms of experimental criteria and particle size distribution in the non-point source pollutants removal system. As a result of the filtration experiments with the cotton ball shape filter, the initial headloss was about 8 cm, and the headloss slightly increased over filtration time. The Kozeny-Carman equation was used to analyze the changes of pressure and porosity during the filtration. The initial porosity was calculated as 0.945 and it decreased to 0.936 at the end of design filtration time. As the filtration continued, the SS concentration of the filtered water gradually increased and the SS removal rate gradually decreased. When the SS target removal efficiency is assumed to be 80%, the cumulative SS removal capacity is expected as $28.8kg/m^2$. This means the volume loading rate of the cotton ball shape filter can be $115m^3/m^2$ when the typical SS concentration of non-point source water pollution is assumed as 250 mg/L.

Development of the Engineered Filter Media for Reducing Pollutants in Urban Runoff (도시지역 불투수면의 오염물질 유출저감을 위한 여재 개발 및 처리 특성 평가)

  • Kang, Sung Won;Lee, Jai Young;Kim, Seog Ku
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.391-396
    • /
    • 2011
  • Recently it revealed that urban runoff was one of the major source that contaminates the river, lake and estuary because it contains toxic compounds such as heavy metals and Poly Aromatic Hydrocarbons (PAHs) as well as suspended solids, organic compounds and nutrients. The engineered polymetric media in this research were developed for reducing pollutants in urban runoff and would be used to be charged in the storm water treatment equipment. The engineered media that were composed of the polypropylene was foamed to have the buoyancy and then shattered by mechanical for the efficient filtration. In this study, Spherical Expanded Polypropylene Media (SEPM), Crushed Polypropylene Media (CPM), Large Crushed Expanded Polypropylene Media (LCEPM), Small Crushed Expanded Polypropylene Media (SCEPM) were made from polypropylene. Surface characteristics of the developed media were determined by scanning electron microscopy analyses. Also, removal efficiencies of SS, $COD_{Cr}$ in the artificial road runoff and the bed headloss by media and particle pollutants captured by media were examined. Results on the surface characteristics of media indicated that SCEPM had the largest specific surface area, $0.80m^2/g$, the lowest specific gravity, 0.091, and the biggest porosity, 0.63, because of crushing the media at the process of manufacturing. And the SCEPM's removal efficiencies of TSS and $COD_{Cr}$ in the artificial road runoff were 92.9% and 83.6%, respectively and the headloss of SCEPM was the least of them.

Evaluation of Head Loss within In-Line Mixer for Water Treatment using CFD Technique (CFD모사 기법을 이용한 관내 혼화장치내 수두손실 발생 특성 평가)

  • Hwang, Young-Jin;Lim, Sung-Eun;Kim, Seong-Su;Park, No-Suk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.1
    • /
    • pp.107-112
    • /
    • 2009
  • This study was conducted for verification and systematization of estimation method about the headloss using CFD(Computational Fluid Dynamics). Head loss which happens between the inlet and outlet of in-line mixer can be a major factor for the design and construction. Also, this Case studies about the sensitivity related to the velocity in the piping system. As result, program's default calculation function was used to get each side's total pressure and the differential of each total pressure could be defined as head loss from in-line mixer. In the case of adopting pipe surface friction factor and geometry loss, Calculation residual can be much more reduced. It was found that residual of value between CFD method and field test ranged about 3 through 18 precent.