Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성 (Characteristics of Superconductive Pb shield for a Whole Head MEG System)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF

3차원 유한 요소법을 이용한 골절판의 응력 해석 (Numerical Stress Analysis of bone plate System using 3-dimensional finite element method)

  • 김현수;권영수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1991년도 춘계학술대회
    • /
    • pp.74-78
    • /
    • 1991
  • Conventional compression bone fracture plates sometimes cause osteoporosis under the plate due to their high rigidity which in turn transfer physiological load mostly through the plates and screws. In order to prevent the osteopenia we have designed a system which have a viscoelastic washer between plate and screw head. The washer is made of a biocompatible ploymer (untra high molecular weight polyethylene, UHMWPE). Three-dimensional finite element meshes of the human femur with the conventional and new concept bone plate ere generated and the comparative stress analyses are performed with static half-stance loading condition. The results of analyses showed that could reduce the stress shielding effect compared with the conventional plate.

  • PDF

안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가 (Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit)

  • 곽용국;홍순기;하민용;박장필;유숙현;조웅
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2015
  • 목 적 : 안와 주변 방사선 치료 시 수정체 피폭선량감소를 위하여 사용된 2차 차폐 block의 유용성을 알아보고자 한다. 대상 및 방법 : Human phantom(Alderson Rando Phantom, The Phantom Laboratory, USA)을 사용하여 CT(Somatom Definition AS, Siemens, Germany) 모의촬영 후 전산화치료계획시스템(Pinnacle, PHILIPS, USA)을 통해 실제 치료와 유사한 IMRT치료계획을 실시하였다. 2차 차폐를 위하여 두께 3mm 지름 25 mm의 납판과 3 mm tungsten eye-shield block(Extra small size, Radiation Products Design, Inc, USA)를 사용하였으며, TPS(Treatment Planning System) 상의 lens dose와 모의치료 상의 lens dose를 OSLD로 측정 비교하였다. 또한, 5 cm 두께의 acrylic phantom에 동일한 조건의 2차 차폐물인 3 mm 납판과 tungsten eye-shield block을 사용하여 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$)를 조사 및 측정하였으며, 조사야 밖의 누설선 및 투과방사선 영향을 제한시키고자 8 cm 납블럭(O.S.B: Outside Scatter Block)을 적용하여 위와 동일한 실험을 시행하였다. 조사야로부터 1 cm 이격하여 phantom 끝 옆면에 OSLD(Optically Stimulated Luminescence Dosimeter)를 부착하였고, eyelid의 두께에 해당하는 bolus 3 mm를 적용하였다. 결 과 : human phantom을 이용하여 IMRT 치료계획 상의 Lens dose와 실 측정치는 각각 315.9, 216.7 cGy가 측정되었고, 3 mm 납판과 tungsten eye-shield block으로 2차 차폐 후 각각 234.3, 224.1 cGy가 측정되었다. acrylic phantom을 이용한 실험 결과는 no block, 3 mm 납판, tungsten eye-shield block을 사용했을 때 5.24, 5.42, 5.39 cGy가 측정되었으며, 조사야 밖에 O.S.B를 적용하여 no block, 3 mm 납판, tungsten eye-shield block을 실험한 결과 각각 1.79, 2.00, 2.02 cGy가 측정되었다. 결 론 : 광자선 조사 시 critical organ을 보호하기 위하여 2차 차폐를 적용할 시에는 field 외부일지라도 헤드 누설방사선 및 collimator & MLC 투과방사선이 존재하므로 치료부위와 beam 방향에 따라 금속과 같은 높은 원자번호의 차폐물질이 critical organ근처에 있다면 선량 증가의 원인이 될 수 있다는 사실을 알 수 있었다. 따라서 피폭선량 감소를 위한 2차 차폐의 시도는 분명 의미가 있었으나 미 검증된 시도는 오히려 역효과를 가져올 수 있다는 사실을 인지하여 QA를 통해 목적에 부합하는 결과가 나오는지를 사전에 알아보아야 할 것이다.