• Title/Summary/Keyword: head replacement

Search Result 115, Processing Time 0.021 seconds

The Threshold Based Cluster Head Replacement Strategy in Sensor Network Environment (센서 네트워크 환경의 임계값 기반 클러스터 헤드 지연 교체 전략)

  • Kook, Joong-Jin;Ahn, Jae-Hoon;Hong, Ji-Man
    • Journal of Internet Computing and Services
    • /
    • v.10 no.3
    • /
    • pp.61-69
    • /
    • 2009
  • Most existing clustering protocols have been aimed to provide balancing the residual energy of each node and maximizing life-time of wireless sensor networks. In this paper, we present the threshold based cluster head replacement strategy for clustering protocols in wireless sensor networks. This protocol minimizes the number of cluster head selection by preventing the cluster head replacement up to the threshold of residual energy. Reducing the amount of head selection and replacement cost, the life-time of the entire networks can be extended compared with the existing clustering protocols. Our simulation results show that our protocol outperformed than LEACH in terms of balancing energy consumption and network life-time.

  • PDF

SURGICAL RESECTION OF CAROTID BODY TUMOR WITH CAROTID ARTERY REPLACEMENT (경동맥 절제후 혈관치환술을 시행한 경동맥체 종양)

  • Choi, Geon;Lee, Eun-Soo;Jung, Kwang-Yoon;Choi, Jong-Ouck
    • Korean Journal of Bronchoesophagology
    • /
    • v.2 no.2
    • /
    • pp.280-284
    • /
    • 1996
  • Carotid body tumors are uncommon tumors of the head and neck Surgery is the primary treatment for the tumor. Large carotid body tumors frequently encircle the common, internal, and exernal carotid arteries, and extensive bleeding often complicates the resection, increasing the risk of carotid artery rupture and damange to major cranial nerves. Grafting should be used in high-risk patients. We have experienced a case of carotid body tumor which encircle the common, internal and external carotid arteries, treated with ligation of external carotid artery and grafting using Gortex between common carotid artery and internal carotid artery.

  • PDF

Contact Stress Analysis of Artificial Hip Joints Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • Kim, Chung-Kyun;Yoon, Jong-Deok
    • Tribology and Lubricants
    • /
    • v.13 no.1
    • /
    • pp.82-87
    • /
    • 1997
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires a re-replacement of hip joints because it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focussed on the development of new materials. The research of new materials, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find new combinations of bio-materials in the total hip replacement which has the excellent contact characteristics. A non-linear FEM program MARC with 5-node axisymmetric element was used for analyzing the contact stresses between the hip joints. The computed results show that in case of acetabulum UHMWP has good characteristics, in femoral head, $Al_2O_3$, and in stem, Ti6Al4V.

A Study on the Contact Stress Analysis of the Artificial Hip Joint Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • 김청균;윤종덕
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.189-194
    • /
    • 1996
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires the re-replacement of the hip joint beacuse it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focused on the development of the new materials. The research of new material, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find the new combination of the materials in the total hip replacement which has the excellent contact characteristics. The finite element uses MARC and the 5-node aximetric element. The results show that in case of acetabulum UHMWP has good characteristics, in femoral head, the $Al_2O_3$, and in stem, Ti6Al4V.

  • PDF

A cluster head replacement based on threshold in the Internet of Things (사물인터넷에서 임계치 기반의 클러스터 헤드 교체 기법)

  • Kim, Jeong-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.11
    • /
    • pp.1241-1248
    • /
    • 2014
  • An efficient battery usage of sensor nodes is main goal in a sensor network, which is the substructure of Internet of Things. Maximizing the battery usage of sensor nodes makes the lifetime of sensor network increase as well as the reliability of the network improved. The previous solutions to solve these problems are mainly focused on the cluster head selection based on the remaining energy. In this paper, we consider both the head selection and the replacement interval which is determined by a threshold that is based on the remaining energy, density of alive nodes, and location. Our simulation results show that the proposed scheme has outstanding contribution in terms of maximizing the life time of the network and balancing energy consumption of all nodes.

A weight-based cluster head replacement algorithm in the Internet of Things (사물인터넷에서 가중치 기반 클러스터 헤드 교체 알고리즘)

  • Kim, Jeong-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.91-96
    • /
    • 2014
  • Since the sensors of Internet of Things (IOT) collect various data, the lifetime of sensor network is very important and the data should be aggregated efficiently. The contiguous collection by the certain sensors occurs an excessive battery consumption and successive transmission of same value of data should be avoided. To solve these things, we propose an weight-based cluster head replacement method that divides whole network into several grids and cluster head is selected by remaining energy, density of alive sensors and location of sensor. The aim of algorithm maximizes the lifetime of network. Our simulation results shows that the proposed method is very simple as well as balances energy consumption.

Short- to mid-term outcomes of radial head replacement for complex radial head fractures

  • Baek, Chung-Sin;Kim, Beom-Soo;Kim, Du-Han;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.183-189
    • /
    • 2020
  • Background: The purpose of the current study was to investigate short- to mid-term outcomes and complications following radial head replacement (RHR) for complex radial head fractures and to identify factors associated with clinical outcomes. Methods: Twenty-four patients with complex radial head fractures were treated by RHR. The mean age of the patients was 49.8 years (range, 19-73 years). Clinical and radiographic outcomes were evaluated for a mean follow-up period of 58.9 months (range, 27-163 months) using the visual analog scale (VAS) score for pain, the Mayo elbow performance score (MEPS), the quick disabilities of the arm, shoulder and hand (Quick-DASH) score, and serial plain radiographs. Complications were also evaluated. Results: At the final follow-up, the mean VAS score, MEPS, and Quick-DASH score were 0.6±1.1, 88.7±11.5, and 19.4±7.8, respectively. The mean range of motion was 132.7° of flexion, 4.7° of extension, 76.2° of pronation, and 77.5° of supination. Periprosthetic lucency was observed in six patients (25%). Heterotopic ossification was observed in four patients (16.7%). Arthritic change of the elbow joint developed in seven patients (29.2%). Capitellar wear was found in five patients (20.8%). Arthritic change of the elbow joint was significantly correlated with MEPS (P=0.047). Four cases of complications (16.6%) were observed, including two cases of major complications (one stiffness with heterotopic ossification and progressive ulnar neuropathy and one stiffness) and two cases of minor complications (two transient ulnar neuropathy). Conclusions: RHR for the treatment of complex radial head fractures yielded satisfactory short- to mid-term clinical outcomes, though radiographic complications were relatively high.

Mechanical safety evaluation of ceramic ball head for total hip replacement using finite element method (인공고관절 전치환술에서 세라믹 볼 헤드의 기계적 안정성 평가를 위한 유한요소 해석)

  • Han, Sung-Min;Chu, Jun-Uk;Chun, Heoung-Jae;Kim, Jung-Sung;Choi, Kui-Won;Youn, In-Chan
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • A ceramic articulating system in total hip replacement thought to be superior to metal-on-polyethylene due to its extremely low coefficient of friction and potential for high resistance to wear. But ceramic is brittle, which makes it mechanically and theoretically susceptible to fracture under certain mechanical conditions. In the current study, nine different models of ceramic ball heads were mechanically evaluated using 3D finite element(FE) analyses. It was found that the maximum stress in all ceramic models was lower than ceramic flexural strength, and it satisfied the requirements of the FDA Gaudience for artificial hip implant. Thus, ceramic ball head models introduced in the current study could be mechanically safe for clinical applications.