• Title/Summary/Keyword: head model

Search Result 1,585, Processing Time 0.034 seconds

A Survey Study on the Perception for Development of Integrated Medical Service Model and Its Application in Clinical Field - A Survey study with Doctors and Korean Medicine Doctors - (통합의료서비스 모델 개발 및 임상 현장 적용을 위한 인식조사 - 의사직 대상 설문 -)

  • Sangwoo Seo;Hyungsuk Kim;Seung Hyeun Lee;Moonkyoo Kong;Beom-Joon Lee;Sung Hyuk Heo;Seung-won Kwon;Bong Jin Park;Dong Hwan Yun;Euiju Lee;Hyunjoo Oh;Sung-Bum Kim;Hye-Sook Choi;Kwan-Il Kim;Won-Seok Chung
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.65-75
    • /
    • 2023
  • Objectives: Objectives: In this study, we define a medical service type that combines Western medicine, Korean medicine, and complementary and alternative medicine (CAM) as an integrated medical service. This study, as part of tertiary hospital-based integrated medical service model and clinical field application, aims to collect status and opinions on integrated medical service for medical staff in the field. Methods: This is a survey study, and was conducted on doctors from Kyung Hee University Hospital and Korean medicine doctors from Kyung Hee University Korean Medicine Hospital. Respondents were recruited on a first-come, first-served basis until the number of respondents reached 120. The investigation was conducted for a total of 16 days from October 4, 2021 to October 19, 2021 by e-mail. Results: Recognition of integrated medical services was confirmed to be 45.8%, and 49.2% responded positively to the necessity of it. As a group of diseases that require the establishment of integrated medical services in the future, 'disorders of musculoskeletal systems and connective tissues' was the highest. The most expected advantages of providing integrated medical services were 'increased satisfaction of patients and guardians' and 'increased treatment effects.' Conclusions: In this study, we investigated the perception of doctors and Korean medicine doctors on integrated medical services that combine Western medicine, Korean medicine, and CAM. It has been confirmed that medical staff generally have a positive perception of integrated medical services, and if the scientific basis for the effect of integrated medical services is supported, the rate of positive perception is expected to increase.

A Study of the Reactive Movement Synchronization for Analysis of Group Flow (그룹 몰입도 판단을 위한 움직임 동기화 연구)

  • Ryu, Joon Mo;Park, Seung-Bo;Kim, Jae Kyeong
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.1
    • /
    • pp.79-94
    • /
    • 2013
  • Recently, the high value added business is steadily growing in the culture and art area. To generated high value from a performance, the satisfaction of audience is necessary. The flow in a critical factor for satisfaction, and it should be induced from audience and measures. To evaluate interest and emotion of audience on contents, producers or investors need a kind of index for the measurement of the flow. But it is neither easy to define the flow quantitatively, nor to collect audience's reaction immediately. The previous studies of the group flow were evaluated by the sum of the average value of each person's reaction. The flow or "good feeling" from each audience was extracted from his face, especially, the change of his (or her) expression and body movement. But it was not easy to handle the large amount of real-time data from each sensor signals. And also it was difficult to set experimental devices, in terms of economic and environmental problems. Because, all participants should have their own personal sensor to check their physical signal. Also each camera should be located in front of their head to catch their looks. Therefore we need more simple system to analyze group flow. This study provides the method for measurement of audiences flow with group synchronization at same time and place. To measure the synchronization, we made real-time processing system using the Differential Image and Group Emotion Analysis (GEA) system. Differential Image was obtained from camera and by the previous frame was subtracted from present frame. So the movement variation on audience's reaction was obtained. And then we developed a program, GEX(Group Emotion Analysis), for flow judgment model. After the measurement of the audience's reaction, the synchronization is divided as Dynamic State Synchronization and Static State Synchronization. The Dynamic State Synchronization accompanies audience's active reaction, while the Static State Synchronization means to movement of audience. The Dynamic State Synchronization can be caused by the audience's surprise action such as scary, creepy or reversal scene. And the Static State Synchronization was triggered by impressed or sad scene. Therefore we showed them several short movies containing various scenes mentioned previously. And these kind of scenes made them sad, clap, and creepy, etc. To check the movement of audience, we defined the critical point, ${\alpha}$and ${\beta}$. Dynamic State Synchronization was meaningful when the movement value was over critical point ${\beta}$, while Static State Synchronization was effective under critical point ${\alpha}$. ${\beta}$ is made by audience' clapping movement of 10 teams in stead of using average number of movement. After checking the reactive movement of audience, the percentage(%) ratio was calculated from the division of "people having reaction" by "total people". Total 37 teams were made in "2012 Seoul DMC Culture Open" and they involved the experiments. First, they followed induction to clap by staff. Second, basic scene for neutralize emotion of audience. Third, flow scene was displayed to audience. Forth, the reversal scene was introduced. And then 24 teams of them were provided with amuse and creepy scenes. And the other 10 teams were exposed with the sad scene. There were clapping and laughing action of audience on the amuse scene with shaking their head or hid with closing eyes. And also the sad or touching scene made them silent. If the results were over about 80%, the group could be judged as the synchronization and the flow were achieved. As a result, the audience showed similar reactions about similar stimulation at same time and place. Once we get an additional normalization and experiment, we can obtain find the flow factor through the synchronization on a much bigger group and this should be useful for planning contents.

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net (II) - Opening Efficiency of the Model Net according to Front Weight and Wing-end Weight - (무부자 쌍끌이 중층망 어구어법의 개발 (II) - 추와 날개끝 추의 무게에 따른 모형어구의 전개성능 -)

  • 유제범;이주희;이춘우;권병국;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.189-196
    • /
    • 2003
  • In this study, the vertical opening of the non-float midwater pair trawl net was maintained by controlling the length of upper warp. This was because the head rope was able to be kept linearly and the working depth was not nearly as changed with the variation of flow speed as former experiments in this series of studies have demonstrated. We confirmed that the opening efficiency of the non-float midwater pair trawl net was able to be developed according to the increase in front weight and wing-end weight. In this study, we described the opening efficiency of the non-float midwater pair trawl net according to the variation of front weight and wing-end weight obtained by model experiment in circulation water channel. We compared the opening efficiency of the proto type with that of the non-float type. The results obtained can be summarized as follows:1. The hydrodynamic resistance was almost increased linearly in proportion to the flow speed and was increased in accordance with the increase in front weight and wing-end weight. The increasing rate of hydrodynamic resistance was displayed as an increasing tendency in accordance with the increase in flow speed. 2. The net height of the non-float type was almost decreased linearly in accordance with the increase in flow speed. As the reduced rate of the net height of the non-float type was smaller than that of the net height of the proto type against increase of flow speed, the net height of the non-float type was bigger than that of the proto type over 4.0 knot. The net width of the non-float type was about 10 m bigger than that of the proto type and the change rate of net width varied by no more than 2 m according to the variation of the front weight and wing-end weight. 3. The mouth area of the non-float type was maximized at 1.75 ton of the front weight and 1.11 ton of the wing-end weight, and was smaller than that of the proto type at 2.0∼3.0 knot, but was bigger than that of the proto type at 4.0∼5.0 knot. 4. The filtering volume was maximized at 3.0 knot in the proto type and at 4.0 knot in the non-float type. The optimal front weight was 1.40 ton.

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

Numerical Hydrodynamic Modeling Incorporating the Flow through Permeable Sea-Wall (투수성 호안의 해수유통을 고려한 유동 수치모델링)

  • Bang, Ki-Young;Park, Sung Jin;Kim, Sun Ou;Cho, Chang Woo;Kim, Tae In;Song, Yong Sik;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.63-75
    • /
    • 2013
  • The Inner Port Phase 2 area of the Pyeongtaek-Dangjin Port is enclosed by a total of three permeable sea-walls, and the disposal site to the east of the Inner Port Phase 2 is also enclosed by two permeable sea-walls. The maximum tidal range measured in the Inner Port Phase 2 and in the disposal site in May 2010 is 4.70 and 2.32 m, respectively. It reaches up to 54 and 27%, respectively of 8.74 m measured simultaneously in the exterior. Regression formulas between the difference of hydraulic head and the rate of interior water volume change, are induced. A three-dimensional numerical hydrodynamic model for the Asan Bay is constructed incorporating a module to compute water discharge through the permeable sea-walls at each computation time step by employing the formulas. Hydrodynamics for the period from 13th to 27th May, 2010 is simulated by driving forces of real-time reconstructed tide with major five constituents($M_2$, $S_2$, $K_1$, $O_1$ and $N_2$) and freshwater discharges from Asan, Sapkyo, Namyang and Seokmoon Sea dikes. The skill scores of modeled mean high waters, mean sea levels and mean low waters are excellent to be 96 to 100% in the interior of permeable sea-walls. Compared with the results of simulation to obstruct the flow through the permeable sea-walls, the maximum current speed increases by 0.05 to 0.10 m/s along the main channel and by 0.1 to 0.2 m/s locally in the exterior of the Outer Sea-wall of Inner Port. The maximum bottom shear stress is also intensified by 0.1 to 0.4 $N/m^2$ in the main channel and by more than 0.4 $N/m^2$ locally around the arched Outer Sea-wall. The module developed to compute the flow through impermeable seawalls can be practically applied to simulate and predict the advection and dispersion of materials, the erosion or deposion of sediments, and the local scouring around coastal structures where large-scale permeable sea-walls are maintained.

Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases- (선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) -)

  • Kim, Kun Ho;Park, Young Kwan;Jee, Heng Ok;Kim, Young Tae;Rhee, Chong Bae;Chung, Yun Chae;Oh, Chull Soo
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF

Ttrosine Hydroxylase in Japanese Medaka (Oryzias latipes): cDNA Cloning and Molecular Monitoring of TH Gene Expression As a Biomarker (송사리 Tyrosine Hydroxylase: cDNA 클로닝 및 생물지표로서의 TH 유전자 발현의 분자생물학적 추적)

  • Shin, Sung-Woo;Kim, Jung-Sang;Chon, Tae-Soo;Lee, Sung-Kyu;Koh, Sung-Cheol
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.4
    • /
    • pp.131-137
    • /
    • 2000
  • The release of hazardous waste materials into the environment poses serious risks in humans and ecosystems. The risk assessment of environmental pollutants including hazardous chemicals requires a comprehensive measurement of hazard and exposure of the chemicals that can be achieved by toxicity evaluation using a biological system such as biomarkers. In this report we have tried to develop a biomarker used to elucidate a molecular basis of, and to monitor abnormal behaviors caused by diazinon in Japanese medaka (Oryzias latipes) as a model organism. First, an attempt was made to clone tyrosine hydroxylase gene from Japanese medaka that would be a candidate for a biomarker for neuronal modulations and behaviors. For monitoring experiments at behavioral and molecular biological levels, the fish were treated under different sublethal conditions of diazinon and their behavioral responses were observed . In this study we have successfully cloned a partial TH gene from the medaka fish through PCR screening of an ovary cDNA library. DNA sequencing analysis revealed that the amplified fragment was 327 bp encoding 109 amino acids. Comparing the DNA sequence of medaka TH with other species, TH gene revealed the DNA sequence was completely identical to that of rat TH. In the RT-PCR, 330 Up of mRNA was consistently amplified in all the treated samples including control There were no significant differences in the TH expression level regardless of treating concentrations (1∼5,000 ppb) and time (0∼48 hr) The reason appeared to be that RT-PCR was not performed using through a quantitative analysis normalized against an actin gene expression. Organ or tissue - specific detection of TH activity and mRNA as biomarkers will be a useful monitoring tool for neurobehavioral changes in fish influenced by toxic chemicals. Furthermore, quantitative analysis of locomotive patterns and its correlation with the neurochemical and molecular data would be highly useful in measuring toxicity and hazard ofvarious environmental pollutants.

  • PDF

A study on the comparison by the methods of estimating the relaxation load of SEM-pile (SEM파일의 이완하중 산정방법별 이완하중량 비교 연구)

  • Kim, Hyeong-Gyu;Park, Eun-Hyung;Cho, Kook-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.3
    • /
    • pp.543-560
    • /
    • 2018
  • With the increased development in downtown underground space facilities that vertically cross under a railway at a shallow depth, the demand for non-open cut method is increasing. However, most construction sites still adopt the pipe roof method, where medium and large diameter steel pipes are pressed in to form a roof, enabling excavation of the inside space. Among the many factors that influence the loosening region and loads that occur while pressing in steel pipes, the size of the pipe has the largest impact, and this factor may correspond to the magnitude of load applied to the underground structure inside the steel pipe roof. The super equilibrium method (SEM) has been developed to minimize ground disturbance and loosening load, and uses small diameter pipes of approximately 114 mm instead of conventional medium and large diameter pipes. This small diameter steel pipe is called an SEM pile. After SEM piles are pressed in and the grouting reinforcement is constructed, a crossing structure is pressed in by using a hydraulic jack without ground subsidence or heaving. The SEM pile, which plays the role of timbering, is a fore-poling pile of approximately 5 m length that prevents ground collapse and supports surface load during excavation of toe part. The loosening region should be adequately calculated to estimate the spacing and construction length of the piles and stiffness of members. In this paper, we conducted a comparative analysis of calculations of loosening load that occurs during the press-in of SEM pile to obtain an optimal design of SEM. We analyzed the influence of factors in main theoretical and empirical formulas applied for calculating loosening regions, and carried out FEM analysis to see an appropriate loosening load to the SEM pile. In order to estimate the soil loosening caused by actual SEM-pile indentation and excavation, a steel pipe indentation reduction model test was conducted. Soil subsidence and soil loosening were investigated quantitatively according to soil/steel pipe (H/D).