• Title/Summary/Keyword: head measurements

Search Result 479, Processing Time 0.029 seconds

A Simple Estimation of the Viscous Resistance of Ships by Wake Surveys

  • Shin-Hyoung,Kang;Beom-Soo,Hyun
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.19 no.2
    • /
    • pp.19-25
    • /
    • 1982
  • Several formulae have been proposed to estimate the viscous resistance of ships by wake surveys. Both the total head and the velocity should be measured. The integration of he total head loss shows over estimations of the resistance by about 10%. Therefore measurements of the velocity are required, which need much more works. A simple method is suggested in this paper to take accout of the velocity-defect from the measured total head. It gives reasonable estimations of the viscous resistance within the experimental accuracy. Experimental data of a low-drag body of revolution in the wind-tunnel and Series 60 model, CB=0.6 in the tank are used to verify the suggested formula.

  • PDF

Coolant Flow Characteristics and Cooling Effects in the Cylinder Head with Coolant Flow System and Local Water Passage (냉각수 공급방식 및 국부적인 물통로의 형상 변화에 따른 냉각수 유동특성 및 연소실 벽면의 냉각효과)

  • 위신환;민영대;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.32-41
    • /
    • 2003
  • For the countermeasure of expected higher thermal load in miller cycle engine, coolant flows in the cylinder head of base engine with several coolant flow methods and drilled hole passages were measured by using PIV technique. And the cooling effect was evaluated by measurements of wall temperatures according to each coolant flow method. It was found that the series flow system was most suitable among the discussed 3 types of coolant flow methods since it had the best cooling effect in cylinder head by the fastest coolant flow velocity It was also found that for drilled water passage to decrease the large thermal load in exhaust valve bridge, nozzle type is more effective compared with round type of water passage, and its size has to be determined according to the coolant flow pattern and velocity in each cylinder.

Systematic study of Criconematoidea from Korea. 3 Two new and one known species of Criconematoidea from Korea (NEmatoda : Tylenchida) (한국산 환선충상과의 계통분류학적 연구. 3. 환선충상과의 2신종 및 1미기록종 보고)

  • Young Eoun Choi;Etienne Geraert
    • Korean journal of applied entomology
    • /
    • v.34 no.4
    • /
    • pp.350-359
    • /
    • 1995
  • Among recent materials identified from Korea two species of Criconematoidea are different from described forms: Criconemella hawangiensis is larger and has a longer stylet than C. paragoodey, head an tail annuli also differ. Hemicycliophora parajuglandis has an outbulging lip area that sits like a hemicircle on the head and pushed the lateral head side inwards; morphology and measurements correspond to H. juglandis and also to H. koreana. Hemicycliophora epichoroides is newly recorded from Korea.

  • PDF

Effects of the Method of Changing Compression Ratio on Engine Performance in an SI Engine (가솔린 엔진에서 압축비 변경 방법이 성능에 미치는 영향)

  • 이원근;엄인용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.27-33
    • /
    • 2001
  • In this study, it is observed that the distribution of combustion chamber volume affects the volumetric efficiency. The distribution ratio was adjusted by controlling combustion chamber volume of head and piston bowl one. Four cases were investigated, which are the combination of different distribution ratios and different compression ratios (9.8-10.0). A commercial SOHC 3-valve engine was modified by cutting the bottom face of the head and/or replacing the piston by the one that has different volume. The result shows that the less the head side volume, the more volumetric efficiency is achieved under the same compression ratio. It is also observed that increasing volumetric efficiency results in early knock occurrence due to increased "real" compression ratio. To consider reliability in estimating the volumetric efficiency, we examined the sensitivity of the AFR equation to possible errors in emission measurements. It is shown that the volumetric efficiency, which is calculated by measuring AFR and fuel consumption, can be controlled in 1% error. 1% error.

  • PDF

Skin Dose Distributions with Spoiler of 6MV x-ray for Head and Neck Tumor (두경부암 치료를 위한 6MV X-선 산란판의 제작과 산란분포 측정)

  • Lee, Ho-Soo;Lee, Jong-Keol;Lee, Byung-Jun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.176-184
    • /
    • 1995
  • It is very useful benefits to use the megavoltage photon beams in deep site tumor radiotherapy for skin sparing effects. But, In some cases of head and mock tumors, it is often necessary to use spoiler for rapid buildup on skin region. A spoiler with tissue equivalent material to be moved between the patients and the collimator can increase or control the skin dose and buildup region due to position and thickness of the spoiler was measured. Then, the effect of spoiler on skin dose and build up region in protruded tumor of head and neck was evaluated quantitatively. The measurements were abtained with PTW 2334 chamber (Markus type) on a polystylene phantom for 6MV x-ray from an accelerator.

  • PDF

Changes of lateral cephalometric values according to the rotation of head (두부회전에 따른 측모두부방사선 계측치의 변화)

  • Kim, Kwang-Soo;Hwang, Mee-Sun;Choi, Eui-Hwan;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.1 s.78
    • /
    • pp.53-66
    • /
    • 2000
  • This study was performed to find out the effect of projection errors on cephalometric linear and angular measurements according to head rotation during taking lateral cephalometric radiographs. Seventeen skulls with permanent dentition and no gross asymmetry were obtained from the Department of Anatomy, Medical School, Chosun University. Total 527 x-ray films were taken with $1^{\circ}$ interval from the reference position($0^{\circ}$) to ${\pm}15^{\circ}$ around the vertical axis (Z axis) which is perpendicular to the midpoint of the line connecting the center of two ear rods in submento-vertex direction. Statistical analysis was performed by paired t-test if there were statistically significant differences between the mean of the reference position($0^{\circ}$) and that of each rotation angle. The following results were obtained. 1. The projection errors of angular measurements were smaller than those of linear measurements. 2. The projection errors of angular measurements including midline landmarks were smaller than those including bilateral landmarks. 3. The horizontal linear measurements were gradually decreased when the stroll was rotated toward the film, but slightly increased and then decreased when the skull was rotated toward the focal spot. However, the changes were smaller in focal direction. 4. The projection errors of horizontal linear measurements were larger than those of vertical linear measurements. 5. The projection errors of vertical linear measurements were increased with increased distance from the rotation axis to vertical measurements. It is concluded that the use of angular measurements rather than linear measurements is recommended to minimize the projection errors.

  • PDF

Numerical Simulation of Head Related Transfer Functions and Sound Fields (수치해석을 이용한 머리전달함수의 계산 및 음장해석)

  • ;V. Kahana;P. A. Nelson;M. Petyt
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.94-103
    • /
    • 2001
  • The goal of using numerical methods in this study is two-fold: to replicate a set of measured, individualized HRTFs by a computer simulation, and also to visualise the resultant sound field around the head. Two methods can be wed: the Boundary Element Method (BEM) and the Infinite-Finite Element Method (IFEM). This paper presents the results of a preliminary study carried out on a KEMAR dummy-head, the geometry of which was captured with a high accuracy 3-D laser scanner and digitiser. The scanned computer model was converted to a few valid BEM and IFEM meshes with different polygon resolutions, enabling us to optimise the simulation for different frequency ranges. The results show a good agreement between simulations and measurements of the sound pressure at the blocked ear-canal of the dummy-head. The principle of reciprocity provides an effect method to simulate HRTF database. The BEM was also used to investigate the total sound field around the head, providing a tool to visualise the sound field for different arrangements of virtual acoustic imaging systems.

  • PDF

Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.169-174
    • /
    • 2016
  • The aim of this study is to investigate the delivery accuracy of intensity-modulated radiation therapy (IMRT) plans in the two-headed mode of the ViewRay$^{TM}$ system in comparison with that of the normal operation treatment plan of the machine. For this study, a total of eight IMRT plans and corresponding verification plans were generated (four head and neck, two liver, and two prostate IMRT plans). The delivered dose distributions were measured using ArcCHECK$^{TM}$ with the insertion of an ionization chamber. We measured the delivered dose distributions in three-headed mode (normal operation of the machine), two-headed mode with head 1 disabled, two-headed mode with head 2 disabled, and two-headed mode with head 3 disabled. Therefore, a total of four measurements were performed for each IMRT plan. The global gamma passing rates (3%/3 mm) in three-headed mode, head 1 disabled, head 2 disabled, and head 3 disabled were $99.9{\pm}0.1%$, $99.8{\pm}0.3%$, $99.6{\pm}0.7%$, and $99.7{\pm}0.4%$, respectively. The difference in the gamma passing rates of the three- and two-headed modes was insignificant. With 2%/2 mm, the rates were $96.6{\pm}3.6%$, $97.2{\pm}3.5%$, $95.7{\pm}6.2%$, and $95.5{\pm}4.3%$, respectively. Between three-headed mode and head 3 disabled, a statistically significant difference was observed with a p-value of 0.02; however, the difference was minimal (1.1%). The chamber readings showed differences of approximately 1% between three- and two-headed modes, which were minimal. Therefore, the treatment plan delivery in the two-headed mode of the ViewRay$^{TM}$ system seems accurate and robust.

Effects of the Head-Turn Gait on Gait Parameters in the Elderly (노인에서 머리회전을 동반한 보행이 보행변수에 미치는 영향)

  • Lee, Myoung-Hee;Chang, Jong-Sung
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.435-440
    • /
    • 2021
  • Purpose: The purpose of this study is to investigate the effects of older adult's head-turn gait on gait parameters by comparing with head oriented forward gait and to provide criteria for their risk of falling compared to young adult. Methods: The subjects were 19 young adults in their 20s and 18 older adults in their 60s or above residing in Daegu or Gyeongsangbuk-do. To evaluate their gait parameters, spatiotemporal gait parameters were measured using a gait analysis tool (Legsys, BioSensics, USA) under two conditions: 1) walking while keeping one's eyes forward and 2) walking while turning the head. The measurement for each test was performed after one practice session, and the mean value of three measurements was analyzed. The collected data were statistically processed using a two-way analysis of variance (ANOVA) to compare any differences in gait parameters between the two groups under the two conditions. The statistical significance level was set at α=0.05. Results: According to the comparison of gait parameters in young adult and older adult between the head oriented forward gait and head-turn gait, statistically significant differences were observed in two parameters: stride length according to the height ratio and stride speed obtained by dividing the stride length according to the height ratio by time (p<0.05). Conclusion: The results of this study indicate that the head-turn gait causes greater differences in stride length and speed among older adult than in young adult and therefore can act as a cause of falling.

Correction of Bilateral Cleft Lip Using Modified Noordhoff Technique (개선된 Noordhoff 방법을 이용한 양측성 구순열의 교정)

  • Cho, Byung Chae;Lee, Yong Jig
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.399-406
    • /
    • 2006
  • Purpose: The authors accessed the anthropometric measurements of fourty non-cleft normal a three-month-old infant and using this obtained data as a basic guideline, authors applied the modified Noordhoff technique for the treatment of bilateral cleft lip. Methods: Over a period of 10 years, a total of 21 bilateral cleft lips were operated. 13 cases of complete and 8 cases of incomplete bilateral cleft lip and palate. In the complete type of bilateral cleft palate, elastic head cap and passive intraoral appliance were applied at 1 to 2 week of age for 2 months duration. The definitive cheiloplasty was performed at 3 months of age using the modified Noordhoff technique. Results: After a follow-up period ranging one to nine years, most patients presented with cosmetically and functionally satisfying results, with an exception of two cases where an undesired peaking effect of the vermilion and dimpling of the vermilion mucosa was encountered. Conclusion: Accessing the anthropometric measurements of fourty non-cleft normal three-month-old infant and using this obtained dara as a guideline, the modified Noordhoff technique can be applied to either complete or incomplete bilaterally cleft lip providing more naturally pleasing and cosmetically satisfying scars that lie in harmony with the philtral ridges, lip tubercle positioned just below the vermilion and a distinct white line and Cupid's bow.