• Title/Summary/Keyword: head measurements

Search Result 477, Processing Time 0.025 seconds

A COMPARATIVE ANALYSIS OF CLASS II DIVISION 1 TREATMENTS : ADOLESCENTS CONTRASTED WITH ADULTS (성장기 아동과 성인에서의 II급 1류 부정교합치료양상에 관한 두부방사선 계측학적 비교연구)

  • Kang, Bo-Seon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.247-261
    • /
    • 1995
  • The purpose of this study was to quantitate differences in the nature of the correction of Angle's Class II div 1 malocclusion dependent on the patient's age at the time of treatment. The sample consisted of 27 female patients in the adolescent group with a mean initial records age of 11.8 years and 25 female patients in the adult group with a mean starting age of 21.1 yrs. Lateral cephalometric head films were taken before and after orthodontic treatment with four bicuspid extraction. The results were obtained as follows. 1. None of maxillary skeletal parameters exhibited a significantly different in treatment change between adolescents and adults. But, in mandibular skeletal measurements, there were significant differences between two groups. (P<0.05) 2. Measures of vertical dimension in the adults remained unchanged during treatment, reflecting the effective absence of growth. 3. The steepness of occlusal plane in the adults changed significantly.(P<0.05) In contrast, the adolescents displayed stability of the occlusal plane. 4. According to the Johnston analysis, there was a significant difference in the total molar correction between two groups.(P<0.05) 5. According to the Johnston analysis, differential mandibular growth in the adolescents contrubuted $63\%$ of the total molar correction, with orthodontic tooth movement accounting for the remaining $37\%$. In the adults, dental movement comprised $99\%$ of the correction.

  • PDF

Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines (이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.184-190
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for one periapical radiography using the portable and wall type dental X-ray machines. Materials and methods: Thermoluminescent chips were placed at 25 sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable and wall type dental X-ray machines. For one periapical radiography taken by portable dental X-ray machine, the exposure setting was 60 kVp, 2 mA and 0.2 seconds, while for one periapical radiography taken by wall type dental X-ray machine, exposure setting was 70 kVp, 8 mA and 0.074 seconds. Absorbed dose measurements were performed and equivalent doses to individual organs were summed using ICRP 103 to calculate effective dose. Results: In the upper anterior periapical radiography using portable dental X-ray machine and in the lower posterior periapical radiography using both machines, the highest absorbed dose was recorded at the mandible body. The effective dose in upper anterior periapical radiography using portable and wall type dental X-ray machines was $4{\mu}Sv$, $2{\mu}Sv$, respectively. In the lower posterior periapical radiography, the effective dose for each portable and wall type dental X-ray machines was $6{\mu}Sv$, $2{\mu}Sv$. Conclusion: It was recommended that the operator use prudently potable dental X-ray machine because that the effective dose in the periapical radiography using wall type dental X-ray machine was lower than that in the periapical radiography using portable dental X-ray machine.

Correlation of Changes of Intracranial Pressure and Clinical Manifestations in Spontaneous Intracerebral Hemorrhage (자발성 뇌실질내혈종 환자에서의 뇌압변화와 임상증상과의 관계)

  • Chung, Eul-Soo;Ko, Sam-Kyu;Kim, Oh-Lyong;Chi, Yung-Chul;Choi, Byung-Yearn;Cho, Soo-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.2
    • /
    • pp.35-44
    • /
    • 1991
  • Recently many authors have reported about the relationship of the volumes of hemorrhage in the brain parenchyme, hemorrhagic sites, optimal operation time, and the effects of mannitol and steroid on control of ICP to clinical manifestations. Many attempts to measue ICP in hydrocephalus, brain tumor, and head injury have been reported. But the measurements of intracranial pressure in spontaneous intracerebral hemorrhage are rare. Intracranial pressure was monitored prospectively in 30 patients who had stereotaxic surgery for spontaneous intracerebral hemorrhage. The results are as follows. 1. Intracranial pressure was increased in high $PaCO_2$. 2. There were no correlation in ICP, rebleeding and ADL at discharge(P > 0.05). 3. ICP was the most high level in 72 hours after operation. 4. There was 63.2% decrease in ICP after litigation with 6000 IU urokinase in the site of hemorrhage. 5. There was no correlation between the numbers of natural drainage and ADL at discharge(P > 0.05). 6. The higher the initial GCS, the higher the Postoperative GCS.

  • PDF

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

Multiple Intraabdominal Solid Organ Injuries after Blunt Trauma (외상후 복부 다발성 고형장기 손상)

  • Park, Hyung Do;Kim, Sun Hyu;Lee, Jong Hwa;Hong, Jung Seok;Hong, Eun Seog
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.193-198
    • /
    • 2009
  • Purpose: This study evaluated the characteristics and the prognosis of multiple intraabdominal solid organ injuries, including those to the liver, spleen, and kidney, after blunt trauma. Methods: From January 2001 to March 2009, 39 patients with multiple intraabdominal solid organ injuries, which had been confirmed by contrast-enhanced computed tomography after blunt trauma, were included in this retrospective study. The injury severity score (ISS), abbreviated injury scale (AIS), revised trauma score (RTS), American Association for the Surgery of Trauma (AAST) injury grade of solid organs, initial hemodynamic status, blood gas analysis, blood transfusion, and the mortality were the main outcome measurements. Results: Injured groups were classified into liver/kidney (n=17), liver/spleen (n=4), spleen/kidney (n=13), and liver/kidney/spleen (n=5) groups. Patients were older in the liver/kidney group than in the liver/kidney/spleen group (43 vs 18 years, p=0.023). The initial systolic blood pressures tended to be lower in the liver/kidney group than in the other groups (84 vs 105, 112, and 114 mmHg, p=0.087). The amounts of 24-hour packed RBC transfusion were 32 units in the liver/kidney group and 4 units in the liver/kidney/spleen group, but the difference was not statistically significant. Differences were found in neither the RTS, ISS, and AIS for head, chest, abdominal, and pelvic injuries nor the AAST injury grade for solid organ, but injuries to the chest were more severe in the liver/spleen group than in the spleen/kidney group (AIS 4.0 vs 2.8, p=0.028). Conservative treatment was the most frequent applied treatment in all groups. There were 6 mortalities : 3 due to hypovolemia, 2 to sepsis, and 1 to brain injury. Mortalities occurred only in the liver/kidney group. Conclusion: Patients who had intraabdominal solid organ injuries of the liver and the kidney simultaneously, tended to be transfused more at an early time after trauma, to have lower initial systolic blood pressures, and to have a higher mortality.

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Mospholops Mosphogicel Chauge on the Derelopmest of Duitus Oeferers of Meat Trppe Cockerds (육닭 정관의 발육에 따른 형태학적 변화)

  • 한방근;김우권;이재홍
    • Korean Journal of Animal Reproduction
    • /
    • v.8 no.1
    • /
    • pp.46-55
    • /
    • 1984
  • The purpose of the experiment was to clarify morphologically normal growth pattern of the ductus deference in accordance with the sex maturity of meat-type cockerels. 1. Diameter of lumens in u, pp.r, mid and lower parts of ductus deferens, the most conspicuous enlargement of lumen was observed in the lower part. Heights of epithelial layers of ductus deferens showed abrupt growth at 12 weeks of age with subsequent gradual growth in all the part of u, pp.r, mid and lower, and heights of those at 30 weeks were a, pp.oximately 4 times as large in the u, pp.r and mid parts and 5 times as large in the lower part in contrast to those at 4 weeks of age. Thickness of muscular layer of ductus showed gradual growth in contrast with the diameter of lumen and height of epithelial layer, showing 1.3 times as large in the u, pp.r part, 1.6 times in the mid part and 1.9 times in the lower part at 30 weeks of age in contrast to the thickness at 4 weeks of age. 2. Within 10 weeks after hatching, lining cells of ductus deferens were mainly composed of round cells and columnar cells in simple columnar epithelium. During 10th to 20th week, the lining cells were mainly composed of high columnar cells and round cells in pseudostratified epithelium. From 22nd week, the lining cells were composed of pseudostratified columnar cells. Whereas round cells disa, pp.ared gradually. Enlargement of lumen and pooling of sperms in ductus deferens coincided with the maturation of seminiferous tubules. 3. In simple correlation between the values of testis weight and the values from various measurements in the ductus deferens, there was significant correlation coefficient with each other. 4. In the India ink absorption test, India ink granules were not absorbed on the epithelium of the ductus deferens, but the granules reactive to acid phosphatase a, pp.ared in a line on the free border of each parts of the ductus deferens. The granules reactive to alkaline phosphatase were noted on the luminal border of ductus deferens mainly, but weak reaction showed than acid phophatase were a, pp.ared. The granules reactive to PAS were a, pp.ared mostly near on the free border of hte epithelial cells of ductus deferens. 5. Number of sperm, Indes of sperm vitality and MRT in the different parts of ductus deferens were tended to be somewhat dominant in the mid and lower parts than in u, pp.r part, even though not significant in the statistical analysis. Ratio of sperm abnormality was tended to be relatively high in the u, pp.r part too, and in the sperm of abnormality blunted head was less in number significantly in the mid and lower part than in the u, pp.r part.

  • PDF

Fuel Concentration Measurements by Laser Rayleigh Scattering (레이저 Rayleigh 산란을 이용한 연료농도 계측시 잡음원인과 대책)

  • Kwon, Soon-Tae;Lee, Jae-Won;Park, Chan-Jun;Ohm, In-Young
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.189-197
    • /
    • 2008
  • In this study, a system to measure continuously the fuel concentration in a steady flow rig on the basis of Rayleigh scattering is presented. The system can be employed to measure both the temporal and the spatial distribution. Also, it is possible to calibrate the system for the measurement of accurate absolute concentration. Firstly, the system was tested at a calibration chamber for the determination of scattering cross section from propane, butane, acetylene, Freon-12 and Genetron 143a. After this, the system was adapted to a steady flow rig to measure the temporal and spatial fuel concentration. The rig is composed of cylinder head, intake manifold, injector, and transparent cylinder which can simulate internal combustion engine. To cope with the interference of Mie scattering, which is main obstacle of the measuring concentration with Rayleigh scattering, a hardware filter was installed for reducing the number density of particles. Furthermore a software filter was developed, which is based on the rise time and the time constant of the photomultiplier-amplifier system. In addition, background noisy was reduced by adjusting the optical array and applying the pin hall and beam trap. The results show that LRS can provide useful information about concentration field and the software filter is very effective method to remove Mie interference.

3-D CT EVALUATION OF CONDYLE HEAD POSITION, MANDIBULAR WIDTH, AND MANDIBULAR ANGLE AFTER MANDIBULAR SETBACK SURGERY (3-D CT를 이용한 악교정수술후의 하악 과두 위치와 하악폭경 및 하악각의 평가)

  • Kim, Jae-Won;Lee, Dong-Hyun;Lee, Su-Youn;Kim, Jae-Hyun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.229-239
    • /
    • 2009
  • The purpose of this study is to evaluate the change in condylar position, width, and angle before and after orthognathic surgery using 3-dimensional computed tomograph. Pre and posterative 3-D CT was taken on 38 patients and through axial, frontal, sagittal measurements and by 3-dimensional reconstruction, the changes in condylar postion, mandibular width and angle were analyzed and others such as the difference in gender, operation and fixation method, setback length and in relation with temporomandibular disorders were done together too. The results were as follows: The inward rotation of condyle in axial condylar angle, the forward movement of right condyle in sagittal anterior-posterior distance, the superior movement of both condyles in sagittal superior-inferior distance, the decrease in gonial angle, the increase in mandibular width, the decrease in distance between the axial coronoid process distance and the increase in the frontal intercondylar distance were statistically significant. There were no statistically significant changes in gender difference, however in the difference in operation method, change in the gonial angle was observed and there was more change in bilateral sagittal split osteotomy group compared to two-jaw surgery group. In the difference in fixation method, the decrease in axial coronoid process distance and the change in sagittal anterior-posterior distance were statistically significant. In the difference in setback, the increase in setback didn't relate directly with the increased change in condyle position. In the relation with temporomandibular disorder, changes in left axial condylar angle and axial coronoid process distance were statistically significant. Changes in condylar position could be observed after the orthognathic surgery but it doesn't seem to have much of a clinical importance. The orthognathic surgery is effective in decreasing the mandibular angle, and it is not related with the temporomandibular disorder.

Load Transfer Mechanism of Drilled Shafts in Weathered Rock (풍화된 암반에 근입된 현장타설말뚝의 하중전이기구)

  • ;Cho Sung-Min;Jung Sung-Jun;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.187-196
    • /
    • 2005
  • Since the allowable bearing capacities of piles in weathered/fractured rock are mainly governed by settlement, the load-displacement behavior of pile should be known accurately. To predict pile head settlement at the design stage, the exact understanding of the load-transfer mechanisms is essential. Therefore, in this research, the load-transfer mechanism of drilled shaft socketed into weathered rock was investigated. For the investigation, five cast-in-place concrete piles with diameters of 1,000 mm were socketed into weathered gneiss. The static axial load tests and the load-transfer measurements were performed to examine the axial resistant behavior of the piles. A comprehensive field/laboratory testing program on weathered rock at the Held test sites was also performed to describe the in situ rock mass conditions quantitatively. And then, the effect of rock mass condition on the load transfer mechanism was investigated. The f-w (side shear resistance-displacement) curve of the pile in moderately weathered rock reached to yielding point at a for millimeter displacements, and after yielding point, the rate of resistance increment dramatically decreased. However, the f-w curve in the highly/completely weathered rock did not show the obvious yielding point, and the resistance gradually increased showing the hyperbolic pattern until relatively high displacement (>15 mm). The q-w (end bearing resistance-displacement) curves showed linear response at least until the base displacement of approximately 10 mm, regardless of rock mass conditions.