• Title/Summary/Keyword: head measurements

Search Result 479, Processing Time 0.028 seconds

Effect of Chin Tuck Exercises on Various Postures and Muscle Activity of the Neck and Shoulder (다양한 자세에 따른 턱 당기기 운동이 목과 어깨의 근활성도에 미치는 영향)

  • Ahn, Su-Hong;Yang, Ju-Hui;Lee, Su-Kyong;Park, Jin-Sung;Jo, Jae-Sung
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.403-414
    • /
    • 2020
  • Purpose: This study examined how performing chin tuck exercises in supine, sitting, and standing positions affects changes in the muscle activity of the neck and shoulder. Methods: Seventeen men and three women with forward head posture participated in the study. The subjects performed the chin tuck exercise using a pressure biofeedback unit. After determining the ideal order for performing the chin tuck exercise in supine, sitting, and standing positions through randomized controlled trials, muscle activity was measured in the dominant-side sternocleidomastoid, scalenus anterior, upper trapezius, and levator scapulae. Muscle activity was measured three times in each muscle for each position, and the average of the three measurements was used for analysis. Results: In this study, the chin tuck exercise performed in a supine position reduced muscle activity of the sternocleidomastoid, scalenus anterior, upper trapezius, and levator scapulae significantly more than performing the exercise in either sitting or standing positions (p < 0.05). No significant difference in muscle activity was observed when the exercise was performed in a sitting position versus a standing position (p < 0.05). Conclusion: Performing a chin tuck exercise in a supine position is more effective for stabilizing the neck and shoulder than performing it in a sitting or standing position, as it reduces excessive tension and fatigue in the neck and shoulder.

Usefulness of Vocal Fatigue Index for Hypertension of Extrinsic Laryngeal Muscles (후두외근 과긴장에 대한 음성피로도 검사의 유용성)

  • Kim, Ji-Sung;Lee, Dong-Wook
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.3
    • /
    • pp.124-129
    • /
    • 2021
  • Background and Objectives This study compares Vocal Fatigue Index (VFI) scores according to the presence or absence of external laryngeal tension in hyperfunctional voice disorder. And through this, it is to confirm the usefulness of VFI to hypertension of extrinsic laryngeal muscles. Materials and Method The subjects were 61 female diagnosed with hyperfunctional voice disorder (hypertension group 41, non-hypertension group 20). The author palpated extrinsic laryngeal muscles for evaluation of hypertension and classified them as the presence or absence. The voice measurements were jitter, shimmer, Korean-Voice Handicap Index-10 (K-VHI-10), and Korean-Vocal Fatigue Index (K-VFI). The voice compared were according to the diagnosis and presence of hypertension only for patients with hyperfunctional voice disorder. Results As a result of comparing the voice measurement according to the presence or absence of hypertension, there was no significant difference in the acoustic variables, K-VHI-10 and K-VFI-Total, K-VFI-Fatigue. Whereas, K-VFI-Physical (p=0.006) and K-VFI-Rest (p=0.022) were significantly higher in the hypertension group. Conclusion These results indicate that the hypertension group has more physical discomfort and less voice recovery than the group without hypertension. It means that K-VFI can measure the physical discomfort and limitations of voice recovery due to hypertension of the external laryngeal muscle. The VFI can be used as one of the methods to evaluate the hypertension of the external laryngeal muscle in Hyperfunctional voice disorder.

Effect of Digital Noise Reduction of Hearing Aids on Music and Speech Perception

  • Kim, Hyo Jeong;Lee, Jae Hee;Shim, Hyun Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.4
    • /
    • pp.180-190
    • /
    • 2020
  • Background and Objectives: Although many studies have evaluated the effect of the digital noise reduction (DNR) algorithm of hearing aids (HAs) on speech recognition, there are few studies on the effect of DNR on music perception. Therefore, we aimed to evaluate the effect of DNR on music, in addition to speech perception, using objective and subjective measurements. Subjects and Methods: Sixteen HA users participated in this study (58.00±10.44 years; 3 males and 13 females). The objective assessment of speech and music perception was based on the Korean version of the Clinical Assessment of Music Perception test and word and sentence recognition scores. Meanwhile, for the subjective assessment, the quality rating of speech and music as well as self-reported HA benefits were evaluated. Results: There was no improvement conferred with DNR of HAs on the objective assessment tests of speech and music perception. The pitch discrimination at 262 Hz in the DNR-off condition was better than that in the unaided condition (p=0.024); however, the unaided condition and the DNR-on conditions did not differ. In the Korean music background questionnaire, responses regarding ease of communication were better in the DNR-on condition than in the DNR-off condition (p=0.029). Conclusions: Speech and music perception or sound quality did not improve with the activation of DNR. However, DNR positively influenced the listener's subjective listening comfort. The DNR-off condition in HAs may be beneficial for pitch discrimination at some frequencies.

Effect of Digital Noise Reduction of Hearing Aids on Music and Speech Perception

  • Kim, Hyo Jeong;Lee, Jae Hee;Shim, Hyun Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.4
    • /
    • pp.180-190
    • /
    • 2020
  • Background and Objectives: Although many studies have evaluated the effect of the digital noise reduction (DNR) algorithm of hearing aids (HAs) on speech recognition, there are few studies on the effect of DNR on music perception. Therefore, we aimed to evaluate the effect of DNR on music, in addition to speech perception, using objective and subjective measurements. Subjects and Methods: Sixteen HA users participated in this study (58.00±10.44 years; 3 males and 13 females). The objective assessment of speech and music perception was based on the Korean version of the Clinical Assessment of Music Perception test and word and sentence recognition scores. Meanwhile, for the subjective assessment, the quality rating of speech and music as well as self-reported HA benefits were evaluated. Results: There was no improvement conferred with DNR of HAs on the objective assessment tests of speech and music perception. The pitch discrimination at 262 Hz in the DNR-off condition was better than that in the unaided condition (p=0.024); however, the unaided condition and the DNR-on conditions did not differ. In the Korean music background questionnaire, responses regarding ease of communication were better in the DNR-on condition than in the DNR-off condition (p=0.029). Conclusions: Speech and music perception or sound quality did not improve with the activation of DNR. However, DNR positively influenced the listener's subjective listening comfort. The DNR-off condition in HAs may be beneficial for pitch discrimination at some frequencies.

Evaluation of Repair Welding Method and PWHT Properties for Degraded CrMoV Casting Steel (열화된 CrMoV 주조강에 대한 보수 용접 방법 및 후열처리 특성 평가)

  • Hong, Jaehun;Jun, Moonchang;Jung, Kwonsuk;Lee, Young-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.3
    • /
    • pp.121-129
    • /
    • 2022
  • Recently the growth of the renewable energy production has caused the flexible operation in LNG combined cycle power plant. Due to the rapid start and stop operations, large CrMoV castings used for turbine casings and valve bodies could be distorted and lead to replacement or welding repair. This study was performed to find out the characteristics of the repair welding for a damaged CrMoV casting steel. A typical field repair method (arc & TIG welding) was applied to making specimens. The degraded N2 packing head sample from the steam turbine was used. The evaluations of weldments were carried out in terms of microstructural characterization, microhardness measurements, tensile, creep-rupture and fatigue tests. Color etching was also applied for better understanding of welding microstructures. As the boundary between HAZ and base material was deteriorated by welding, it caused microstructural changes formed during PWHT and the shortening of the remaining residual life. By comparing the properties according to repair welding method, it was possible to derive what important welding factors were. As a result, arc welding method is more suitable for repair welding on CrMoV castings.

The Effect of Computer Game and Stretching on Muscle Tone and Concentration (컴퓨터 게임과 스트레칭이 근 긴장도 및 집중력에 미치는 영향)

  • Ko, Min-Gyun;Song, Chang-Ho;Lee, Byung-Hoon
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.1
    • /
    • pp.225-233
    • /
    • 2019
  • The study was to find out the effects of computer game and stretching on muscle tone and concentration. The subjects were 30 adults, who were divided into 15 stretching group and 15 control group after applying computer game for 120 minutes. The subjects measured muscle tone and concentration before experiment, the same measurements were made before and after applying the stretching. The muscle tone was respectively measured after 60 minutes and 120 minutes of computer game. The results showed that muscle tone increased significantly after 60 minutes and 120 minutes of computer game, and significantly decreased in the stretching intervention group. Concentration increased significantly after computer game, but there was no significant difference after application of stretching. In this study, computer game increased muscle tone and concentration, and stretching decreased increased muscle tone. Therefore, proper stretching after computer games will reduce musculoskeletal diseases caused by increased muscle tone, and development of appropriate game contents will be an effective tool for concentration training.

A location analysis of Korean traditional housing and farm village based on the Eagi(理氣)theory in Feng Shui : Case study on the head family house of Mr. Kim located in Uisung County, Kyongsang Province (한국농촌지역 전통주택과 마을입지의 이기풍수(理氣風水) 해석 - 의성 김씨 종택을 중심으로 -)

  • Kwon, Y.H
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.11 no.1
    • /
    • pp.3-19
    • /
    • 2009
  • The purpose of this study was to systemize the 'Eagi(理氣)' theory in Feng Shui which has been neglected in Korea because of its difficulties in the current Feng Shui theory and to make it easier to apply in the art of placement. The study also analysed the characteristics of the location of a sample village in terms of Feng Shui. Besides the placement analysis, the interpretation of the Yangtaek(陽宅) theory was analysed on the layout of the outdoor space of the building. As the initial step, various theories about Feng Shui were investigated. Based on those, the framework of the Feng Shui theory was summarized for application to the case study. Yangtaeksamyo(陽宅三要) was referred to for consideration of Feng Shui theory outside the residential buildings. At the same time, configurational analysis of the ground was carried out with the naked eye and actual measurements were taken using a specific compass(佩鐵). The results were summarized as follows : First, the 'Eagi' theory in Feng Shui, which finds a 'lucky site(穴)' selects the 'geomagnetic aspect(坐向)' by analyzing the natural forces of wind and water. In this theory, the aspect was regarded of most importance. 'Yangtaek Feng Shui (陽宅風水)' was the theory that people's ups and downs depends on the direction of the place where they live on, and was developed on the basis of 'I ching(周易)'. Second, the village and the house in the case study have been considered as lucky places from old times and this was equally verified by the 'Eagi (理氣)' theory and the "Yangtaek (陽宅)' theory.

A Study on the Behaviour Analysis and Construction Method of the Self-Supported Earth Retaining Wall (SSR) Using Landslide Stabilizing Piles (2열 H-파일을 이용한 자립식 흙막이 공법(SSR)의 거동분석 및 시공방법에 관한 연구)

  • Sim, Jae-Uk;Park, Keun-Bo;Son, Sung-Gon;Kim, Soo-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.41-54
    • /
    • 2009
  • The purpose of this research is to introduce the new temporary earth retaining wall system using landslide stabilizing piles. This system is a self-supported retaining wall (SSR) without installing supports such as tiebacks, struts and rakers. The SSR is a kind of gravity structures consisting of twin parallel lines of piles driven below excavation level, tied together at head of soldier piles and landslide stabilizing piles by beams. In order to investigate applicability and safety of this system, a series of experimental model tests were carried out and the obtained results are presented and discussed. Furthermore, the measured data from seven different sites on which the SSR was used for excavation were collected and analyzed to investigate the characteristic behavior lateral wall movements associated with urban excavations in Korea. It is observed that lateral wall movements obtained from the experimental model is in good agreement with the general trend observed by in site measurements.

Age-related Differences in Ankle-joint Proprioception and Postural Balance in Women: Proprioception of Force Versus Position

  • Kim, Seo-hyun;Yi, Chung-hwi;Lim, Jin-seok;Lim, One-bin
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.124-130
    • /
    • 2022
  • Background: During postural control, older adults are more dependent on proprioception than are young adults. Ankle proprioception, which plays an important role in maintaining postural balance, decreases with age. Published studies are insufficient to establish a significant age difference in postural sway resulting from the known age-related decrease in ankle proprioception and do not examine various detailed test conditions. Objects: The present study aimed to compare ankle proprioception between older and younger groups along dimensions of position vs. force proprioception and dorsiflexion vs. plantarflexion. The present study also aimed to compare postural sway between young and older women during quiet standing under two sensory conditions. Methods: We recruited seven young women aged 21-24 and seven older women aged 60-63. Ankle proprioception was assessed as the accuracy of the joint position sense (JPS) and the force sense (FS). Postural sway was assessed using center-of-pressure measurements recorded during quiet standing under two sensory positions: eyes open and eyes closed with head tilted back. Results: Older women had lower JPS in dorsiflexion and lower FS in plantarflexion than did younger women. We found no significant age differences in JPS in plantarflexion or in FS in dorsiflexion. We observed a main effect of group on postural sway in two sway parameters out of three. We observed significant differences in JPS with dorsiflexion, and in FS with plantarflexion. Conclusion: Proprioception for ankle plantar flexor decreased more significantly with aging than did that for ankle dorsiflexor, accounting for the impaired postural balance observed in older women.

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.