• Title/Summary/Keyword: head measurements

Search Result 477, Processing Time 0.032 seconds

Contamination of an Alcyon Co-60 Gamma rays by Electrons (Alcyon Co-60 감마선의 전자오염)

  • Yoo Meong-Jin;Kim Dong-Won;Kim Chul-Soo;Chung Woon-Hyuk
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.109-116
    • /
    • 1988
  • The Alcyon Co-60 gamma rays was studied for electron contamination. The surface dose, attributable almost entirely to contamination electrons, has a linear dependence on field width for square fields and an inverse square dependence on distance from the bottom of the fixed head assembly Build-up and surface dose measurements were taken with and without an acrylic blocking tray in place. Further measurements were made with a copper filter designed to reduce secondary electrons emitted by photon interactions with the acrylic tray. The results are discussed in relation to skin sparing effect for radiation therapy Patients. And to achieve the maximum skin sparing effect, the selection of the optimum SSD and TSD is needed.

  • PDF

Measurements of a Round Jet with High-Definition 3D-PTV

  • Hwang, Tae-Gyu;Doh, Deog-Hee;Saga Tetsuo;Kenneth D. Kihm
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1211-1224
    • /
    • 2004
  • Two round jets. impinged and pulsed. were measured with high-resolution 3D-PTV technique. The measurement system consists of three CCD cameras, Ar-ion laser, an image grabber and a host computer. Two fitness functions were introduced in a genetic algorithm in order to enhance the correspondences of the particles. One was based on a concept of the continuum theory and the other one was based on a minimum distance error. The velocity profiles of the impinged jet obtained by the constructed 3D-PTV system were compared with those of LDV measurements made in this study. The head vortex of the jet was visualized by LIF and was reconstructed by the constructed high-resolution 3D-PTV system for comparisons.

두개안 골격형태에 관한 두부방사선학 연구

  • Sehr, Cheong-Hoon
    • The Journal of the Korean dental association
    • /
    • v.18 no.1 s.130
    • /
    • pp.65-70
    • /
    • 1980
  • Lateral cephalometric head film measurements on forty schoolboys and forth-nine schoolgirls with excellent occlusions in Korean were compared with similar measurements on Caucasoids. The following conclusions were obtained. 1. The cranio-facial skeletal pattern of Korean students was measured and compared with Caucasoids. 2. In cranio-facial observation, ANB and SN-Palatal plane was not significant in girls only, Gonial angle and 1 to NA were not significant in girls and boys, compared with Caucasoids. 3. In dentition area observation, the mean posterior dental height (A+B) and occlusal plane length was not significant in girls only, the mean anterior vertical dimension and P angle was not significant in boys, Q angle was not significant in boys in boys and girls, compared with Caucasoids.

  • PDF

A PHOTOMETRIC STUDY OF MAXILLOFACIAL NORMALS IN 19 TO 20 YEARS-OLD KOREAN (한국 성인 19-20세 안모의 실물사진계측분석학적 연구)

  • Jeon, Yong-Il;Kim, Yeo-Gab
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.318-325
    • /
    • 2002
  • The primary method of diagnosis in craniofacial deformity patient is used by gross inspection. So we studied the frontal photometric measurements for maxillofacial Korean normals 44 male and 48 female ages 19 to 20 years were selected from a group of 92 healthy Kyung Hee university students in Seoul.. The photograph were taken with the subject sitting in head position parallel with interpapillary plane to the floor. During taking pictures, facial anallyser by Obwegeser(Martin Co., Germany) was used for correct measurements. The results of this study was followed. 1. In the linear measurements, all values of males were longer than those of females but middle third height and lower third height, facial width and nasal width of males were longer than those of females in p<0.05 2. The difference between right and left angular and linear measurement was insignificant. 3. In the horizontal facial ratios, interocular distance and nasal width were longer and mouth width were smaller in korean than in american(p<0.05). 4. In the vertical ratios, korean women have shorter facial height of lower third comparing with facial height of middle third than american(p<0.05). 5. In the vertical facial ratios, korean have smaller proportion below the stomion in the lower third department than american. (p<0.05).

Growth Patterns of Premature Infants Up to 40th Term Week of Corrected Age (교정나이 40주(만삭)까지 미숙아의 성장패턴)

  • Ahn, Young-Mee;Sohn, Min;Lee, Sang-Mi
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.5
    • /
    • pp.613-622
    • /
    • 2011
  • Purposes: Study purpose were to describe growth patterns of premature infants in weight, length and head circumference from birth to 40th week of corrected ages (CA) and to explore factors affecting patterns. Methods: A longitudinal descriptive study was conducted with 267 premature infants. They were categorized into 2 groups; GA group with measurements at birth and the CA group with measurements at CA, which was categorized into 3 groups (group 1-3) by WHO guideline for gestational age (GA) at birth. Results: GA group presented greater measures in all than CA group at same week of life. Among CA groups, group 3 showed the highest measurements, up to 37 weeks of life, though this disappeared at 38-40 weeks. Reversely, group 1 revealed the highest growth rates in all measures, followed by group 2 and group 3. Significant interaction was observed in all measures between week of life and any type of groups. Conclusions: Higher measures in GA group, as well group 3 among CA groups, supported the superiority of intra-uterine environment overriding quality of regimen from NICU. Regardless of growth acceleration, smaller infants remain smaller, indicating that intra-uterine thrifty phenotype may continue at least up to the 40th week of CA.

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

Analysis of Technical Error of Manual Measurements (직접 측정한 인체치수의 기술적 오차 분석)

  • Park, Jinhee;Nam, Yun Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.641-649
    • /
    • 2016
  • Highly precision body measurements represent basic data required by industry and researches who wish to utilize information about the human body. The proficiency and expertise of the measurers have a significant influence on the error and accuracy of data when various parts from multiple subjects' bodies are measured. Therefore, in order to measure accurate body measurements (when measuring bodies directly), it is necessary to conduct objective analyses on errors. This study calculated the Relative Technical Error of Measurement (%TEM) using data that measured each of 24 subjects and discussed errors and methods to reduce errors by conducting comparison analysis based on measured items and objects. The result of analysis indicated that the errors based on age and gender of the objects of measurement were minor; however, there were comparatively distinct differences in measured errors based on measured items. 'Right and left Shoulder Angle' for all measured subjects displayed the greatest errors and standard deviations. 'Height' dimension, Lateral Malleolus Height and Head Height had big errors; in addition, 'Circumference', Neck Base Circumference and Armscye Circumference also had big errors. More careful measurements of such items with big errors require additional educational plan such as a proposal for more objective and detailed measurement methods. Items with small errors but big standard deviations such as Waist Circumference, Calf Circumference, Minimum Leg Circumference, Chest Circumference, Hip Circumference and Waist Circumference confirmed that errors for them greatly decreased with repeated experiments and resultant measurers increased proficiency; consequently, repeated measuring experiments for these items greatly enhance accuracy.

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.