• 제목/요약/키워드: hazardous air pollutant

검색결과 46건 처리시간 0.021초

경남 김해지역의 대기환경개선 실천계획 수립 전후의 대기질 평가에 관한 연구 (Study on the Assessment of Air Quality Before and After Action Plan of Atmospheric Environment Improvement Establish at Gimhae, Gyeongnam Province)

  • 박종길;정우식;김석철;김은별
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1111-1120
    • /
    • 2008
  • In order to study the degree of improved air quality as an outcome of the action plan of Atmospheric Environment Improvement in Gimhae, Gyeongnam Province, we investigated the status and trends of air pollutant before and after the plan. Nitrogen dioxide and ozone, both classified as hazardous substances, were closely monitored with particular attention. The level of sulfur dioxide, nitrogen dioxide, fine particles and ozone (but for carbon monoxide) was decreased after the plan was implemented. The number of days on which ozone exceeded the National Ambient Air Quality Standard has decreased, but the level was still often exceeded. The level of nitrogen dioxide did not surpass until the 2006 standard, but when the revised 2007 standard was implemented, it exceeded 80% of some standards. The yearly level of ozone has decreased since the plan was introduced. The concentration of nitrogen dioxide, however, has reduced in high order area while increased in low order area.

소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성 (Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station)

  • 김수진;함승헌;전정석;김원
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.140-151
    • /
    • 2019
  • 본 연구에서는 소방관들이 화재현장에서 복귀 후 소방청사 내에서 2차적으로 노출된 화학적 유해물질의 실내공기질을 평가하였다. 서울시에 소재한 4개 소방서를 선정하였고, 그 중 2개 소방서는 실제 화재현장에서 소방활동 종료 귀소 후에, 다른 2개 소방서는 대조군으로 설정하여 출동과 상관없이 평소 수준의 실내공기질을 측정하였다. 소방안전지도 전산시스템을 이용하여 서울시에서 발생하는 모든 화재사고에 대하여 24시간 모니터링을 실시하였고 중급규모 이상의 사고에서 실험군이 출동하게 되는 경우 귀소 후 바로 실내공기질을 측정하였다. 11개 유해물질 항목(미세먼지, 포름알데히드, 휘발성유기화합물, PAH, VCM, 산류, 석면, CO, CO2, NO2, O3)을 공정시험법에 따라 측정하였다. 유해물질 11종 중 3종이 국내·외 기준을 초과하였고 1종은 국외기준에 육박하는 것으로 확인되었다. 특히 총휘발성 유기화합물, 이산화탄소, 황산은 각 2.5배, 2.2배, 1.1배가 환경부 및 고용노동부 기준보다 높았다. 또한, 포름알데히드와 황산의 경우, 실험군보다 대조군에서 더 높게 측정되었다. 본 연구결과는 서울특별시 소방청사 내 실내공기질 개선 정책에 활용될 수 있을 것이다.

Decomposition of NO$_2$ by SPCP

  • Kang, Hyun Choon;An, Hyung Whan;Lee, Han Seob;Hwang, Myung Whan;Woo, In Sung;Kang, An Soo
    • International Journal of Safety
    • /
    • 제1권1호
    • /
    • pp.52-57
    • /
    • 2002
  • The Decomposition of NO$_2$ (nitrogen dioxide), one of the Hazardous Air Pollutant (HAP), was studied by utilizing the SPCP (Surface induced discharge Plasma Chemical Processing) reactor so as to obtain optimum process variables and maximum decomposition efficiencies. Experimental results showed that for the frequency of 10kHz, the highest deco position efficiency of 84.7% for NO$_2$ was observed at the power consumptions of 20W. The decomposition efficiency of $NO_2$ was found to be: 1) proportional to the residence times, and inversely proportional to the initial concentrations of $NO_2$; 2) the maximum when the electrode diameter was 3mm; 3) influenced by the electrode material, decreasing in the order of W>Cu>Al; and 4) proportional to the $CH_4$ content, due to which the highest efficiency of 98% was obtained with almost all the $NO_2$ removed.

화학적 등급화기법을 적용한 농공단지 입주제한업종의 환경유해성 평가 (The Environmental Hazard Assessment of Siting Restricted Industries from Industrial Complex in Rural Area Applied by Chemical Ranking and Scoring System)

  • 홍상표
    • 환경영향평가
    • /
    • 제24권6호
    • /
    • pp.549-560
    • /
    • 2015
  • 농공단지에 입주제한된 31개 업종의 업종별 배출특성에 따른 화학적 유해성을 근거로 업종별 환경영향을 계량화하여 입지규제 우선순위을 도출하였다. 농공단지에 입주제한된 31개 업종의 환경상의 악영향과 환경기술발전에 따른 환경유해성 저감을 동시에 고려한 합리적 토지이용 관리방안을 수립하기 위하여 업종별로 수계, 토양 및 대기의 매체별 배출량 및 배출물질 $LC_{50}$ 자료에 의해 산정된 인체위해성과 생태위해성을 노출평가와 독성평가로 분석하는 화학적 등급화기법(CRS : Chemical Ranking and Scoring System)에 PRTR (Pollutant Release and Transfer Registers) 자료를 활용하였다. 농공단지 폐수배출관련 31개 업종에 대한 환경유해성을 도출한 결과에 의하면 2012년 기준으로 도금 착색 및 기타 표면처리강재 제조업, 생물학적 제제 제조업, 동 제련정련 및 합금 제조업, 솜 및 실 염색가공업, 그외 기타 1차철강 제조업, 기타 비철금속 압연압출 및 연신제품 제조업 등 6개 업종은 환경영향 점수가 상대적으로 낮게 산출되어 제조공정상에서 특정수질유해물질을 배출허용기준 이하로 배출된다고 인정하는 경우에 농공단지 입주제한을 완화시킬 수 있는 업종으로 평가된다.

습식 공기청정장치의 공기오염물질 제거 특성 (Characteristics of a Wet Air Cleaning System for Removal of Air Pollutants)

  • 배귀남;김용표;백남준
    • 대한환경공학회지
    • /
    • 제22권1호
    • /
    • pp.21-31
    • /
    • 2000
  • 본 연구에서는 공기청정기, 기수분리기 및 중성능 필터로 구성되는 습식 공기청정장치를 대상으로 입자와 유해가스인 $SO_2$, NO, $NO_2$, HCHO 및 $NH_3$의 제거 특성을 실험적으로 살펴보고, 실험결과를 대상물질의 물리화학적 특성과 연관시켜 검토하였다. 입자제거 실험에서는 대기 에어로졸을 송풍기를 통해 장치에 도입하여 장치의 3곳에서 2대의 레이저 입자계수기로 입자크기 분포를 측정하여 각 구성요소의 입자제거효율을 구하였다. 실험결과로부터 기수분리기에서는 입경이 $5{\mu}m$ 이상인 조대 입자가 주로 제거되고. 중성능 필터에서는 이보다 작은 미세 입자가 주로 제거됨을 알 수 있었다. 유해가스 제거 실험에서는 시험용 가스를 송풍기의 출구에 주입하여 공기청정기의 상류와 기수분리기의 하류에서 가스농도를 측정하여 유해가스 제거효율을 구하였다. 실험결과로부터 헨리상수가 큰 수용성인 $SO_2$, HCHO 및 $NH_3$는 제거효율이 높았으나, 헨리상수가 낮아 난용성인 NO와 $NO_2$는 제거효율이 낮음을 알 수 있었으며, 공기청정기에서 상당량의 음이온이 발생됨을 알았다.

  • PDF

전이금속 산화물 촉매를 이용한 톨루엔 분해 (Decomposition of Toluene over Transition Metal Oxide Catalysts)

  • 천태진;최성우;이창섭
    • 대한환경공학회지
    • /
    • 제27권6호
    • /
    • pp.651-656
    • /
    • 2005
  • 톨루엔은 섬유산업 공정에서 발생하는 주요한 유해성 대기 오염원으로 간주된다. 본 연구에서는 ${\gamma}-Al_2O_3$를 지지체로 한 전이 금속 산화물 촉매(Cu, Mn, V, Cr, Co, Ni, Ce, Sn, Fe, Sr, Cs, Mo, La, W, Zn)를 제조하여 톨루엔 완전 산화 반응을 조사하였다. XRD, FE-SEM, BET와 TPR 기법을 사용하여 금속 촉매의 특성을 조사하였다. 촉매 가운데 Cu/${\gamma}-Al_2O_3$ 촉매가 가장 우수한 활성을 보여주었다. BET결과 촉매 활성의 증가는 비표면적과는 관련이 적은 것으로 나타났으며, X선 회절 분석에서 대부분의 촉매들이 무정형으로 존재함이 관찰되었다. FE-SEM을 관찰한 결과, 전이금속 산화물 촉매 중 구리산화물 촉매가 지지체 표면에 고르게 분산되어 있음을 확인할 수 있었다. 톨루엔 산화반응에 따른 촉매활성 효과는 ${\gamma}-Al_2O_3$ 지지체 위에 전이금속 산화물 촉매가 고르게 분산된 점과 촉매 표면의 우수한 환원 특성에 기인하는 것으로 설명할 수 있었다.

Monte-Carlo 모의실험을 통한 부분 인구집단별 벤젠 및 PM10의 노출 및 위해성 평가 (Exposure and Risk Assessment of Benzene and PM10 for Sub-populations using Monte-Carlo Simulations)

  • 박진현;양소영;박윤경;류현수;김은채;최영태;허정;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.247-257
    • /
    • 2019
  • Objectives: The Korea Ministry of Environment regulates concentrations of hazardous air pollutants (HAPs) through Atmosphere Environmental Standards to protect public health from HAPs. However, simply determining the exceedance of HAP concentrations has several limitations and more comprehensive assessment is required. In addition, integrated risk assessment is needed considering exposure in all microenvironments, including outdoor as well as indoor environments. The purpose of this study was to assess the differences in risk by sub-population groups according to time-activity patterns and reported concentrations, as well as the lifetime risk for Koreans. Methods: In this study, we calculated time-weighted average exposure concentrations for benzene and $PM_{10}$ among preschool-age children, students, housewifes, workers, and the elderly using residential time and concentrations for indoor (house, school or workplace, other), outdoor, and transport by the meta-analysis method. The risk assessments were conducted by excess cancer risk and disease death risk using 1,000,000 Monte-Carlo simulations for probabilistic analysis. Results: Preschool-age children, students, housewifes, workers, and the elderly spent 91.9, 86.0, 79.8, 82.2, and 77.3% of their day in their house, workplace, or school, respectively. The more than 99% excess cancer risk for benzene exceed 1.0E-06 in all sub-populations and lifetime. The acute disease death risk for $PM_{10}$ for housewifes and workers for lifetime were 3.35E-04 and 3.18E-04, and chronic disease death risks were 2.84E-03 and 2.70E-03, respectively. Conclusions: The risk of benzene and $PM_{10}$ by sub-population group and for the lifetime of housewifes and workers were assessed. Benzene showed risky results for this study. All disease death risks of $PM_{10}$ were higher than 1.0E-04 and showed different risks by sub-population. This study can be used as a basis for lifetime exposure and risk assessment to benzene and $PM_{10}$.

배출계수 개발 및 배출량 산정 체계 고도화를 통한 건설기계의 연식, 출력 및 기종별 대기오염물질 배출량 산정 (An Estimation of Age-, Power-, and Type-Specific Emission Inventories for Construction Equipments Using Improved Methodologies and Emission Factors)

  • 진형아;이태우;박하나;손지환;김상균;홍지형;전상진;김정수;최광호
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.555-568
    • /
    • 2014
  • The construction equipment is one of the major sources for hazardous air pollutants in Korea, and the its management has been of great concern recently. The objective of this study was to estimate each contribution of emission of construction equipments according to their production year, electric power consumption and type. To achieve this goal, we developed pollutant emission factors for the machineries manufactured after 2009, which are excluded from the present framework of Korean air pollutants inventory, CAPSS. More than 800 data obtained from emission investigations were utilized for the estimation. Compared with the previous estimation, the scheme used this study was modified to incorporate new emission factors as well as to include the corresponding activity data. Such improvement allow us to gain more detailed emission informations which are better characterized by specifications of construction equipments. The total amount of pollutants emitted from construction equipments in 2011 were estimated as 126.8, 7.0, 58.3, and 17.0 kton for $NO_x$, PM, CO, and VOC, respectively. The estimation results indicate that the increase in the emission of equipments is significantly related to their age and power consumption. The emissions of the older ones manufactured from 1992~1996 were estimated to be the contribution ranged from 23.7% to 26.8%, whereas the newer ones (2009~2011) showed the attributions of 11.3~21.5%. In addition, the results show that the emission of each equipment was increased with the increase in the electric power consumption of engine, probably due to their average output power. Among the nine types of machinery compared, excavators and forklifts were investigated to contribute relatively higher emissions in the level of 39.8~44.0% and 32.0~34.2%, respectively.

흡연시 발암성 물질의 체내 잔존율에 대한 연구 - 주요 휘발성 유기화합물을 중심으로 (Studies on the body - retaining rate of smoking-related carcinogens using some important volatile organic compounds (VOC))

  • 김기현;최여진;홍윤정;양혜순;이진홍;이용기
    • 분석과학
    • /
    • 제17권5호
    • /
    • pp.410-415
    • /
    • 2004
  • 본 연구에서는 담배 흡연과 관련된 유해성분들의 발생특성을 비교하기 위하여, BTEX를 위시한 주요 방향족 VOC 성분과 포름알데하이드와 아세트알데하이드를 포함하는 카보닐 화합물의 분포특성을 다각도로 비교하고자 하였다. 이를 위해, 직접흡연에 해당하는 exhaled mainstream smoke (EMS)와 간접흡연에 해당하는 side-stream smoke (SS) 시료 등을 분석하고, 이들의 농도분포를 비교하였다. 필터를 제거한 상태에서 흡입되는 담배 연기의 경우, 유해한 성분들이 수 백 ppm 수준의 고농도로 존재한다는 것을 확인하였다. 반면, 흡연자가 비흡연시에도 날숨을 통해 이들 성분을 수 십에서 수 백 ppb의 농도로 배출하는 것을 확인할 수 있었다. 이러한 분석결과와 날숨과 들숨의 관계로부터 주요 흡연성분들의 체내 잔류율 등을 유추해 보았다. 이러한 추정에 의하면, 방향족 및 카르보닐 성분들의 대부분이 99% 이상 체내에 잔류할 수 있다는 것을 확인하였다.

DME를 이용한 경유자동차의 유해대기오염물질 발생 특성 연구 (A Study on Hazardous Air Pollutant Emissions From Diesel Engines Utilizing DME Fuel)

  • 임윤성;서충열;곽순철;이종태;박정민;강대일;김종춘;이영재;표영덕;임의순;동종인
    • 한국대기환경학회지
    • /
    • 제22권1호
    • /
    • pp.53-61
    • /
    • 2006
  • Recently, lots of researchers have been attracted to develop various alternative fuels and to use renewable fuels in order to solve the exhaust emission problems. DME (Dimethylether) is synthetic fuel, and can be produced from natural gas, coal and biomass. The emission is clean because it contains little sulfur and aromatic components In this study, the fuel was tested to investigate the applicability as an alternative fuel for diesel. This study was carried out by comparing the exhaust emissions and performance of diesel engine with DME, ULSD (ultra low sulfur diesel), LSD (low sulfur diesel) respectively. In order to measure regulated emissions, CO, $NO_{3}$, HC from vehicle different fuel types were used on chassis dynamometer CVS (constant volume sampler)-75 mode and EPA TO-I1A method was chosen for aldehydes analysis.