• Title/Summary/Keyword: harmonics detection

Search Result 100, Processing Time 0.027 seconds

The harmonics detection system adapting the variation of source frequency (전원 주파수 변동에 적응하는 고조파 검출 시스템)

  • Hwang, Hwan-Young;Choi, Won-Ho;No, Kyung-Ho;Park, Chong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.195-197
    • /
    • 2005
  • This paper proposed the new harmonic detection system for the source current with the large frequency variation. The harmonic detection system is designed of the analog circuit and is composed of a low pass filter, a DC-level converter using the PLL, the Voltage controlled GIC.

  • PDF

Inrush Current Detection of Power Transformer using Flux-current Derivative Curve (자속-전류비율곡선을 이용한 전력용 변압기의 여자돌입검출)

  • Kim, S.K.;Park, C.W.;Shin, M.C.;Suh, H.S.;Jang, B.T.;Kim, I.D.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.186-189
    • /
    • 1996
  • Convential inrush current detection method is used to harmonic restraint method by filtered second frequency component. Nowadays this technique must be modified because harmonics are occurred in steady state of power system. A purpose of this study is to develop of inrush current detection relaying algorithm for power transformer based on flux-current derivative curve method. We used the relaying signals obtained from EMTP simulation.

  • PDF

A Study of Detection Algorithms and Analysis Series Arc of Quasi-arc Load (유사아크부하의 직렬아크신호 분석 및 검출 알고리즘에 관한 연구)

  • Lim, Jong-Ung;Ju, Jae-Yeon;Kang, Kyoung-Pil;Bang, Sun-Bae;Choe, Gyu-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.81-90
    • /
    • 2014
  • This paper proposes new arc algorithm to detect series quasi-arc. This algorithm analyzes odd and even harmonics until 9th using discrete fourier transform (DFT) and detect series arc comparing RMS values of load current. Resistors, lights, dimmer and vacuum cleaner which can be distinguished linearity load and quasi arc load are adopted to perform experiments. This algorithm is confirmed to emulate arc detecting with measuring current data.

An application of operational deflection shapes and spatial filtration for damage detection

  • Mendrok, Krzysztof;Wojcicki, Jeremi;Uhl, Tadeusz
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1049-1068
    • /
    • 2015
  • In the paper, the authors propose the application of operational deflection shapes (ODS) for the detection of structural changes in technical objects. The ODS matrix is used to formulate the spatial filter that is further used for damage detection as a classical modal filter (Meirovitch and Baruh 1982, Zhang et al. 1990). The advantage of the approach lies in the fact that no modal analysis is required, even on the reference spatial filter formulation and other components apart from structural ones can be filtered (e.g. harmonics of rotational velocity). The proposed methodology was tested experimentally on a laboratory stand, a frame-like structure, excited from two sources: an impact hammer, which provided a wide-band excitation of all modes, and an electro-dynamic shaker, which simulated a harmonic component in the output spectra. The damage detection capabilities of the proposed method were tested by changing the structural properties of the model and comparing the results with the original ones. The quantitative assessment of damage was performed by employing a damage index (DI) calculation. Comparison of the output of the ODS filter and the classical modal filter is also presented and analyzed in the paper. The closing section of the paper describes the verification of the method on a real structure - a road viaduct.

A Square Wave Current Compensation of Current Source Induction Motor drives Using Active Power Filter (능동 전력 필터에 의한 유도모터 구동 전류형 인버터의 구형파 전류보상)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.133-136
    • /
    • 2000
  • Current Source Inverter(CSI) operated in square wave mode is more efficient than the PWM CSI because of increased cost greater complexity of control algorithm, and substantial switching losses EMI. But the square wave output current of CSI rich in low order harmonics produce motor torque ripples. Therefore in this paper describes the active power filters for square wave current compensation of current source induction motor. Also extended current synchronous detection(ECSD) as compensation algorithm is proposed. To confirm the validity o proposed system some simulation results are presented and discussed.

  • PDF

Detection of the Extinction Time of Secondary Arc using Even Order Harmonics Distortion (짝수 고조파를 이용한 이차아크 소호 검출 방법에 관한 연구)

  • Lee, Chul-Moon;Lee, You-Jin;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.191_192
    • /
    • 2009
  • 지락고장 발생 시 재폐로 동작을 위하여 필요한 조건은 이차아크의 소호 여부이다. 본 논문에서는 1선 지락고장 발생 시 고장상의 전압 파형에 포함되는 짝수 고조파가 이차아크 소호 판단에 유용한지 분석해 보았다. 모의실험은 765kV 모의계통에 아크 지락고장 모델을 적용하여, 다양한 고장 조건하에 이루어졌다.

  • PDF

Novel islanding detection method for grid connected PV system (계통연계형 태양광발전시스템의 새로운 단독운전 검출기법)

  • Jung, Young-Seok;So, Jung-Hun;Yu, Byung-Gyu;Yu, Gwon-Jong;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1705-1707
    • /
    • 2005
  • This paper proposes a novel active frequency drift(AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic(PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction(cf) enables the islanding detection to drift up(or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD methods, which have a certain value of cf only, is inefficient and difficult to design the appropriate cf value analytically to meet the limit of harmonics. In this paper, the periodic chopping fraction based on an AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with the power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also good performance of islanding detection compare with the conventional AFD method.

  • PDF

Three-Phase Z-Source Hybrid Active Power Filter System (3상 Z-소스 하이브리드 능동전력필터 시스템)

  • Lim, Young-Cheol;Kim, Jae-Hyun;Jung, Young-Gook
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.75-85
    • /
    • 2010
  • In this paper, a Z-source hybrid active power filter is proposed to compensate the harmonics and reactive power in power distribution system. The proposed system is composed of a 7th harmonics-tuned passive filter and an active power filter with a Z-source inverter topology, while voltage source PWM inverter or current source PWM inverter are applied as the power converter topology of conventional active power filters. The Z-source impedance network along with shoot through capability would ensure a constant DC voltage across the DC link. A polymer electrolyte membrane fuel cell is employed as an compensation DC energy source of the proposed system and its equivalent R-L-C circuit is modeled for simulation. As the compensation and control algorithm of the proposed system, the current synchronous detection algorithm is applied. The simulation analysis by PSIM is performed under the three-phase 220V/60Hz voltage source and 25A nonlinear diode loads. The effectiveness of the proposed the system is verified in the steady and transient states.

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

Development of a hight Impedance Fault Detection Method in Distribution Lines using Neural network (신경회로망을 이용한 배전선로 고저항 사고 검출 기법의 개발)

  • ;黃義天
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.212-212
    • /
    • 1999
  • This paper proposed a high impedance fault detection method using a neural network on distribution lines. The v-I characteristic curve was obtained by high impedance fault data tested in various soil conditions. High impedance fault was simulated using EMTP. The pattern of High Impedance Fault on high density pebbles was taken as the learning model, and the neural network was valuated on various soil conditions. The average values after analyzing fault current by FFT of evenr·odd harmonics and fundamental rms were used for the neural network input. Test results were verified the validity of the proposed method.