• 제목/요약/키워드: harmonic modeling

검색결과 185건 처리시간 0.027초

Steady-State Harmonic Domain Matrix-Based Modeling of Four-Quadrant EMU Line Converter

  • Wang, Hui;Wu, Mingli;Agelidis, Vassilios G.;Song, Kejian
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.572-579
    • /
    • 2014
  • As a non-linear time variant system, the four-quadrant line converter of an electric multiple unit (EMU) was expressed by linear time periodic functions near an operating point and modeled by a steady-state harmonic domain matrix. The components were then combined according to the circuit connection and relations of the feedback control loops to form a complete converter model. The proposed modeling method allows the study of the amplitude of harmonic impedances to explore harmonic coupling. Moreover, the proposed method helps provide a better design for the converter controllers, as well as solves the problem in coordination operation between the EMUs and the AC supply. On-site data from an actual $CRH_2$ high-speed train were used to validate the modeling principles presented in the paper.

전자식 안정기의 고조파 저감 대책 (A Study on the Harmonic Analysis of an Electronic Ballast)

  • 최홍규;홍순석;오정석;유태군
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.121-127
    • /
    • 2004
  • Electric ballast is widely used to turn on the fluorescent. Electric ballast measure occurrence of harmonic through the actual measurement and it is simulated by modeling equivalent circuit for harmonic analysis. The purpose of this paper is to give an equivalent circuit modeling methodology for the harmonic currents generated by single-phase personal computer loads to evaluate a commercially available series resonant filter for the harmonic currents compensation based on the IEC std 61000-3-2 and IEEE 519 standards for limiting harmonic distortion.

  • PDF

Modeling of Power Networks by ATP-Draw for Harmonics Propagation Study

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권6호
    • /
    • pp.283-290
    • /
    • 2013
  • This paper illustrates the possibilities of using the program ATP-Draw (Alternative Transient Program) for the modeling of power networks to study power quality problems with highly detailed analyses. The Program ATP-Draw is one of the most widespread and oldest programs. A unique characteristic of this program is its public domain and the existence of forums and study committees where new application cases and modification are presented and shared publicly. In this paper, to study the propagation of harmonics through a power network, a part of an industrial power network was modeled. The network contains different types of electric components, such as transformers, transmission lines, cables and loads, and there is a source of harmonics that injects $3^{rd}$, $5^{th}$, $7^{th}$, $9^{th}$ and $11^{th}$ harmonic currents into the network, causing a distortion of the wave form of the currents and voltages through the power network.

전자식 안정기의 고조파 저감 대책 (A Study on the Hormonic Analysis of on Electronic Ballast)

  • 홍순석;오정석;유태군
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.35-41
    • /
    • 2005
  • 전자식 안정기는 형광등을 점등시키기 위하여 널리 사용되고 있다. 전자식 안정기의 실측을 통해 고조파 발생현황을 측정하고 고조파 해석용 등가회로를 모델링 하여 시뮬레이션을 하였다. 본 논문은 단상 부하의 고조파 해석용 등가회로 모델링과 설계 및 적용 시험을 하여 고조파를 저감시키고, IEC 61000-3-2와 IEEE Std 519-1992를 근거로 평가하였다.

현장시험에 의한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling for Neutral Harmonic Analysis by Field Tests)

  • 김경철;백승현;최종기;이일무;김종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.369-371
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been. known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fell-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed. The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

  • PDF

개별기기 및 종합부하 실험에 의한 고조파 성분을 고려한 전압에 대한 부하역률 모델링 (Voltage-dependent Power-Factor Modeling with Harmonic Component by Static Experiments of Individual and Composite Loads)

  • 신창기;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.230-233
    • /
    • 2004
  • This paper is proposed that The voltage-dependant power factor model is established as 5th polynomials with convenience data type. This modeling includes the harmonic components by static experiments of individual and composite load. This paper suggested methodology for modeling bus and regional power factor with consideration of harmonics effect by load composition rates and individual load power factor models.

  • PDF

직류 마이크로그리드 시스템의 고조파 상태 공간 모델링 (Harmonic State Space Modeling of DC Microgrid Systems)

  • Kamalirad, Mohsen;To, Dinh Du;Lee, Dong-Choon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.483-484
    • /
    • 2019
  • This paper proposes a harmonic state space (HSS) modeling of DC microgrid. In the HSS model, nonlinear equations for the switched circuit model are transformed into multiple linear equations. The simulation results have shown the HSS modeling is comparable with PSIM simulation.

  • PDF

Impedance-Based Stability Analysis of DC-DC Boost Converters Using Harmonic State Space Model

  • Park, Bumsu;Heryanto, Nur A.;Lee, Dong-Choon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.255-261
    • /
    • 2021
  • This paper proposes impedance-based stability analysis of DC-DC boost converters, where a harmonic state space (HSS) modeling technique is used. At first, the HSS model of the boost converter is developed. Then, the closed-loop output impedance of the converter is derived in frequency domain using small signal modeling including frequency couplings, where harmonic transfer function (HTF) matrices of the open-loop output impedance, the duty-to-output, and the voltage controller are involved. The frequency response of the output impedance reveals a resonance frequency at low frequency region and frequency couplings at sidebands of switching frequency which agree with the simulation and experimental result.

고조파를 고려한 방사기저함수 네트워크 기반의 부하모델링 기법 (Load Modeling Method Based on Radial Basis Function Networks Considering of Hormonic components)

  • 지평식;이대종;이종필;임재윤
    • 조명전기설비학회논문지
    • /
    • 제22권4호
    • /
    • pp.46-53
    • /
    • 2008
  • 본 연구에서는 고조파를 고려한 방사기저함수 네트워크 기반의 부하모델링 기법을 개발하였다. 개발된 부하모델은 입력정보로서 기본 주파수와 기본 전압 외에 고조파 성분도 고려하여 전압 및 주파수뿐만 아니라 고조파의 영향에 대해서도 효과적으로 부하를 추정할 수 있도록 구성하였다. 부하모델링을 위해 적용된 방사기저함수 네트워크는 기존에 널리 사용되는 다층 신경망에 비해 구조가 간단하고 수렴속도가 빠른 장점을 지니고 있다. 개발된 부하모델링 기법은 기존에 널리 사용되는 다항식과 다층 신경회로망 및 고조파 성분을 고려하지 않은 방사기저함수 네트워크를 이용한 부하모델 기법과 비교함으로써 제안방법의 타당성을 검증하였다.

Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis)

  • 백승현;김경철;최종기;이일무;백남웅
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.181-187
    • /
    • 2004
  • 3상 4선식 배전계통을 채용하는 우리나라는 비선형 부하의 증가로 중성선에는 많은 중성선 고조파 전류가 관측되고 있다. 또한 접지 임피던스는 고조파가 있는 중성선 전류에 영향 끼친다고 알려져 있다. 전위 강하법에 따라 현장에서 실측한 고조파 전류와 전압을 측정하고, Pattern Search 기법으로 고조파 해석용 접지 임피던스를 모델링 하였다. 여기서 구한 임피던스 모델은 현장 시험에 의한 임피던스 모델과 비교하여 유사한 결과를 얻었고, 접지 시스템의 고조파 및 과도 응답 특성을 평가하는데 활용될 것으로 사료된다.