• 제목/요약/키워드: harmonic load

검색결과 688건 처리시간 0.023초

A Load Compensator Based on One-Cycle Control with Plug-In Repetitive Control

  • Hu, Jian;Sun, Zhaohui;Ma, Hao;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.443-454
    • /
    • 2015
  • This study proposes a novel one-cycle control scheme with a plug-in repetitive controller for load compensator. The novelty of this scheme lies in the combination of high dynamics and the simplicity of a one-cycle controller and good steady-state harmonic suppression ability of the repetitive controller. In addition, the proposed scheme can reduce the effect of the harmonics in phase voltage for the existence of the repetitive controller. Finally, experimental results on a three-phase, four-wire, three-level load compensator are reported to validate the effectiveness of the proposed control scheme.

3상 4선식에시 비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-linear Loads under the 3-Phase 4-Wire Grid System)

  • 김종겸;박영진;이은웅
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.54-62
    • /
    • 2006
  • 3상 4선식 전원공급 시스템에서 단상 및 3상 부하의 운전하에서 전압 불평형은 부하의 불평형 운전에 의해 발생되고, 전류 불평형은 떨어진 전압 품질에 의해 더욱 심해진다. 에너지 변환장치로 사용되는 여러 형태의 컨버터는 3상 4선식 배전시스템에 직접적으로 고조파 전류를 주입함으로서 고조파 왜란을 증가시킨다. 고조파 전류는 전동기 출력 토크를 감소시키고, 전동기를 과열 또는 소음을 증가시키며 회전자에 토크 맥동을 증가하여 기계적인 공진과 진동을 발생하는 등 여러 가지 부작용을 낳고 있다. 따라서 본 논문은 3상 4선식 배전시스템에서 선형 및 비선형 부하의 혼합 운전시 불평형과 고조파 성분에 의해 유도전동기의 특성 변화에 대한 연구로서 선형 단독운전, 비선형 부하 결합에 따른 특성 변화를 해석한 것으로서 단상 비선형 부하의 추가 운전시 5 고조파 필터로도 저감이 어려운 고조파로 인해 토크 맥동 횟수는 줄고 리플값은 증가함을 확인할 수 있었다.

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

회귀 최소 자승법을 이용한 고조파 발생원 추정 연구 (Estimation of Harmonic Sources in a Power System using Recursive Least-Squares Technique)

  • 한종훈;이계병;박창현;장길수
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1639-1645
    • /
    • 2011
  • A technique to allocate responsibilities among the interested parties in electric power system with harmonic voltage distortion at the point of common coupling (PCC) has been presented. The recursive least-squares technique has been used to estimate the parameters of the Thevenin equivalent load model. The validity of the technique has been verified using a simulation which considered the voltage waveform distortion at the PCC between the utility and two industrial consumers. With the estimated data from the measured voltage and current waveform at the PCC, the individual contributions to the distortion of voltage waveform at an interested harmonic frequency have been calculated and could provide a flexible solution to identify the source of harmonic pollution in distribution systems.

Study on the Influence of Grid Voltage Quality on SVG and the Suppression

  • Yi, Guiping;Hu, Renjie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.155-161
    • /
    • 2014
  • Industrial Static Var Generator (SVG) is typically applied at or near the load center to mitigate voltage fluctuation, flicker, phase unbalance, non-sine distortion or other load-related disturbance. Special attention is paid to the influence of grid voltage quality on SVG current, the non-sine distortion and unbalance of grid voltage causes not only the AC current distortion and unbalance but also the DC voltage fluctuation. In order to let the inverter voltage contain the fundamental negative sequence and harmonic component corresponding to the grid voltage, a new dual-loop control scheme is proposed to suppress the influence in this paper. The harmonic and negative sequence voltage decomposition algorithm and DC voltage control are also introduced. All these analyses can guide the practical applications. The simulation results verify the feasibility and effectiveness of the present control strategy and analyses.

가변 부하시 선간전압 변조방식을 이용한 유도전동기의 순시 Torque 제어 (Instantaneous torque control of induction motor with line-to-line voltage modulation on the variable load.)

  • 노종화;우정인;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.645-648
    • /
    • 1991
  • In conventional sinusoidal wave PWM control, torque oscillation is a problem on account of harmonic component. This paper deals with the choice of line-to-line voltage modulation method, which is effective in using DC(direct current) source voltage and in controlling harmonic oscillation, and the pattern to reduce swiching loss through 1/3 pause of switching interral. So, this paper deals with valid realization of harmonic component and high torque response on variable load by simulation and experiments to compensate occurring problems when line-to-line modulation are applied to PWM inverter.

  • PDF

최적 부하 임피던스와 하모닉 튜닝을 이용한 B급 고효율 전력 증폭기의 설계 (Class-B high efficiency power amplifier by harmonic tuning iwth optimum load impedance)

  • 류정호;조영송;신철재
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.52-61
    • /
    • 1996
  • In this paper, harmonic-tuning method to achieve the maximum efficiency is proposed. Harmonic tuning method is applied to the optimum load impedance of a class B amplifier, which is extracted by using the modified cripps method. High efficiency power amplifier utilizing GaAs MESFET is designed and fabricated in the 835MHz band. The performance of th eamplifier is presented by having output power of 30.8dBm, drain efficiency of 80.5% and power added efficiency of 66% with an associated power gain of 7.4dB.

  • PDF

감속 스텝모터를 이용한 2축 인장·전단 시험기의 개발 (Development of Biaxial Tension & Shear Tester using Stepper Motor with Harmonic Driver)

  • 최병선;배원호;채영석
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.379-386
    • /
    • 2001
  • The lower toughness or brittle materials for mechanical test lead to the additional requirement that applied displacements be controlled with high resolution. Biaxial tension and shear tester using stepper motor with harmonic driver is shown. The device had to be high resolution so that the crack initiation process of slow extension and steady growth could be examined, Grip plates were connected to a linear bearing and actuator. The actuators consisted of stepper motors with harmonic driver connected to pre-loaded ball screw and nut assemblies. The encoders and motor controllers were connected to a personal computer so that arbitrary displacements histories could he prescribed in normal and tangential directions. The linear bearings were used to react loads perpendicular to their axes while allowing low friction, parallel movement of the attached grips. Load cells measured the reactions normal and tangential. the loads measured the reactions were recorded by the computer.

  • PDF

인천국제공항 여객터미널의 고조파 측정 및 분석 (Hormonic Measurement and Analysis of Incheon International Airport)

  • 김용하;최상규;이명민;우성민;이범
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.117-123
    • /
    • 2005
  • 본 논문은 허브공항으로의 기능을 담당하고 있는 인천국제공항 여객터미널의 전력품질을 측정하고 분석하여 이에 대한 대책에 관하여 방법을 제시하였다. 각 Load Center는 인천국제공항 여객터미널을 운영하는 수용가의 PCC 점이라 할 수 있다. 그러므로 Load Center의 전력품질을 안전하고 안정적으로 유지하는 것이 중요하다고 할 수 있다. 이를 위해 각각의 위치에 있는 부하 측정지점에서 고조파를 측정${\cdot}$분석하여 대책수립을 위한 Filter의 종류를 제시하였다.

직류 부하에 대한 3상 복합형 전력 필터 설계 (A Design of Three-phase Hybrid Power Filter System for DC Loads)

  • 조동길
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.379-384
    • /
    • 2000
  • The reactive and harmonic current components of dc loads can be compensated by the three-phase hybrid power filter (HPF) system. After compensation, the resulting current has sinusoidal and in-phase components with the source voltage. The HPF system is constructed by an active filter and passive filters. The passive filter reduce the 5th and 7th harmonic of the load current. The active filter compensates the remainder of the load current. Using the HPF system, a low cost harmonic compensator can be made. Performance of the HPF system is verified through simulation,

  • PDF