• Title/Summary/Keyword: harmonic drive

Search Result 211, Processing Time 0.024 seconds

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.

Online Dead Time Effect Compensation Algorithm of PWM Inverter for Motor Drive Using PR Controller

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1137-1145
    • /
    • 2017
  • This paper proposes the dead time effect compensation algorithm using proportional resonant controller in pulse width modulation inverter of motor drive. To avoid a short circuit in the dc link, the dead time of the switch device is surely required. However, the dead time effect causes the phase current distortions, torque pulsations, and degradations of control performance. To solve these problems, the output current including ripple components on the synchronous reference frame and stationary reference frame are analyzed in detail. As a results, the distorted synchronous d-and q-axis currents contain the 6th, 12th, and the higher harmonic components due to the influence of dead time effect. In this paper, a new dead time effect compensation algorithm using proportional resonant controller is also proposed to reduce the output current harmonics due to the dead time and nonlinear characteristics of the switching devices. The proposed compensation algorithm does not require any additional hardware and the offline experimental measurements. The experimental results are presented to demonstrate the effectiveness of the proposed dead time effect compensation algorithm.

Line Current Characteristics of Multilevel H-Bridge Inverters (다중 H-브릿지 인버터의 입력전류특성)

  • Jeong Seung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.335-340
    • /
    • 2004
  • Recently, multilevel H-bridge inverters have become more popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics.

  • PDF

A Gear Changing Technique of an Inverter for Variable Speed Drive Using Hybrid PWM (하이브리드 PWM에 의한 인버터 가변속 운전시의 패턴절환기법)

  • 서영민;박영진;홍순찬
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.64-67
    • /
    • 1998
  • This paper proposes the hybrid PWM scheme that can obtain less harmonic characteristics in GTO inverters. By employing the variable of the dc-link voltage Vdc, the hybrid PWM pattern can ideally compensate the dc input fluctuation together with selected harmonics elimination. The transient behavior, which the magnetic flux and torque are altered and the large current flows instantly, may be produced when the mode change. To reduce such an undesirable transient behavior, it is also presented the technique for the gear changing of inverter operated with the hybrid PWM. The results are verified by simulations and experiments.

  • PDF

A Study on the load control using electric inertia

  • Kim, Gil-Dong;Park, Hyun-Jun;Han, Young-Jae;Jang, Dong-Yuk;Jo, Jung-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.128.1-128
    • /
    • 2001
  • A propulsion system apparatus is needed for a railroad vehicle to test and estimate propulsion performance. The electrical inertia simulator to facilitate the development and testing of propulsion systems, is presented in this paper. It is based on a vector-controlled Induction motor drive supplied from the AC mains through a double PWM converter that provides desirable features such as hi-directional power folw, nearly unity power factor and low harmonic factor at the Ac mains. A theoretical analysis is first presented, followed by a detailed simulation study to assess the overall system performance under dynamic conditions.

  • PDF

Power Parameters Analysis and Evaluation using Visualization of Distortion Factor for Motor Drive System (전동기 구동 시스템의 왜형률 가시화에 의한 전력 파라미터 분석 및 평가)

  • 임영철;정영국
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.15-22
    • /
    • 1998
  • The goal of this paper is to propose analyzing and evaluating method of power parameters for motor drive system with various experimental graphic screens and numerical results and to develop the proposed system. A developed system is made up 586-PC and DSP board, motor drive system, power parameters analyzing and evaluating software for windows. Power parameters are analyzed using correlation signal processing techniques based on the correlation between voltage and current waveforms. Analysis results are visualized by 3-D current coordinates, and it is compared and evaluated with conventional time/ frequency domain. To verify the validity of the proposed system, capacitor run type single phase induction motor and thyristor speed controller is used for analyzing. Power and harmonic parameters of motor drive system is analyzed and verified, with varying fire angle of thyristor speed controller, and the proposed approach is to confirm validity.

A Study on the Harmonic Current Characteristics of Universal Motro with Speed Controller (유니버셜모터 속도제어기의 고조파전류 특성에 관한 연구)

  • 임홍우;박수강;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.132-140
    • /
    • 2001
  • A universal motor is a small dc series machine motor that is designed to operate from an ac machine. The characteristics of universal motors are high no-load and staring torque. Because of the high operating speed, the size of these motors for a given hp rating is typically smaller that other fractional hp ac machine, making it ideal for hand-held tools and appliances where weight, compactness, and speed are importance factors. A phase-angle control with AC drive system gains a high popularity due to their simple implementation, but contains the disadvantage of their poor input power factor, subharmonic current. Pulse width modulation control with DC drive systems increase the power factor as without delay phase angle. This paper analyzed the subharmonic characteristics of the phase angle control system that is controlled by zero voltage crossing similar to traditional method, and the dc chopper system that is used PWM.

  • PDF

Output Filler Design for Noise Reduction of Induction Motor Drive System using H-Bridge 7-Level Inverters (H-Bridge 7레벨 인버터를 이용한 유도전동기 구동시스템의 노이즈 저감을 위한 출력 필터설계)

  • Kim, Soo-Hong;Ahn, Young-Oh;Kim, Yoon-Ho;Bang, Sang-Seok;Kim, Kwang-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.36-44
    • /
    • 2006
  • In general, the generated harmonics and noise of the PWM inverter are affected by PWM switching method, switching frequency, dv/dt and di/dt. Since multilevel inverters are often applied to the high power system, and operates with low switching frequency, theyproduce large size of harmonic contents and noise. Thus it is necessary to install output filters in the multilevel inverter. In this paper a filter design approach for the harmonic and noise reduction the three phase induction motor driving system using H-bridge 7-level inverter system is presented. The passive filter that has low cost and simple structure and can effectively reduce harmonics and noise, is designed and applied to the three phase induction motor drive having multilevel inverter system. The designed system is implemented and verified by simulation and experiments.

A Study on the High Performance Slip Power Recovery System in Induction Motor (유도전동기의 고성능 슬립전력 회수방식에 대한 연구)

  • Park, Han-Ung;Park, Seong-Jin;An, Jin-U;Park, Jin-Gil;Kim, Cheol-U;Hwang, Myeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.8
    • /
    • pp.431-439
    • /
    • 1999
  • Among the variable-speed AC motor drive systems, the static slip power recovery system has been widely adopted in large power drives because a high efficiency drive can be obtained by recovering the slip power to the AC line. Although many improvements have been made in this system, several problems also remain such as the need of transformer in inverter AC side, which results in limiting speed control range and increasing the losses, production of reactive power by the control of inverter firing angle, harmonics in line currents, and so on. This paper presents the novel high performance slip power recovery system using the boost converter and small size filter in the rotor circuit, which recovers slip power of a wound rotor induction machine to AC supply efficiently with the aid of the boost converter, in which most of the problems in conventional system can be solved. The speed can be controlled by the duty ratio of the converter switch, not by inverter firing angle. As a results, the proposed system can operate in high power factor and the harmonic currents caused by the inverter and rectifier can be considerably suppressed. The validity of the proposed system verified by demonstrating the good agreement in the simulation and experimental results.

  • PDF