• Title/Summary/Keyword: handpiece

Search Result 99, Processing Time 0.026 seconds

Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu (대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태)

  • Eun, Jeong-Hwa;Bae, Ji-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece (초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션)

  • Kim, Seung-Won;Yoo, Ju-Hyun;Lee, Jie-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.3
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

A Development of the Control System of BLDC Motor for Micro Motor Handpiece (마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발)

  • Baik, Won-Sik;Song, Hyun-Jig;Kim, Min-Huei;Kim, Dong-Hee;Lee, Heon-Uk;Hwang, Don-Ha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

NUMERICAL ANALYSIS OF INTERNAL CHARACTERISTICS ON DENTAL HIGH-SPEED AIR TURBINE HANDPIECE (의료용 고속 에어터빈 핸드피스의 내부 유동특성에 대한 수치해석)

  • Ryu, K.J.;Youn, D.H.;Baek, J.H.;Lee, D.W.;Kim, D.Y.;Kim, D.Y.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.535-542
    • /
    • 2011
  • To utilizing CFX V12.0.l, internal flow characteristics of denture high-speed air turbine hand-piece unit was identified, in order to analyze the performance of the torque values were compared. In order to find out the difference of torque by mash values, under steady condition, performed grid convergence test. It compared theoretical torque with torque through flow analysis. To describe the motion of turbine blade was used to immerged solid method. Depending on the location of the turbine blade were calculated from five case. Maximum and minimum values of turbine blades was analyzed. To analyze the performance of the torque values were compared with speed of turbine blade.

  • PDF

Tooth Profile Analysis for Face Gear with 1:2 Gear Ratio in Handpiece with 160° Contra Angle (160도 Contra angle을 갖는 소형 핸드피스용 1:2증속기어의 치형 해석)

  • Choi, Jihun;Ahn, Sukyeong;Park, Sangshin
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.86-91
    • /
    • 2014
  • This paper presents a design procedure for a face gear and pinion used in a handpiece with a $160^{\circ}\acute{y}$ contra angle and 1:2 gear ratio. Based on the geometric theory of gearing, the tooth profile of the face gear and pinion is developed. To analyze the contact pressure, the gear profile should be determined before calculating the stress between the two gears. The concept of calculating the face gear profile is that it can be generated by the coordinate transformation of the shaper profiles, which have involute curves, using a simulation method from the gear manufacturing process.

Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality (치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구)

  • Son, Jae-Hwan;Han, Chang-Woo;Choi, Sang-Il;Kim, Yong-Jung;Choi, Chang-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.3
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model (귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석)

  • Mo, Seunghan;Kang, Jungu;Kim, Ik-Hwan;Choi, Hyung-Jun;Song, Je Seon;Shin, Yooseok
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • This study intended to evaluate noise level of dental handpieces and the effects of noise cancelling devices. An ear model was designed to measure the level of the noise delivered to the inner ear during dental handpiece operation. The level of noise was measured in various conditions using the ear model and the portable noise meter. Noise level was measured again after applying of 4 different noise cancelling devices to the model ear. The noise level of dental handpieces was 82.5 - 84.4 dB. When 4 types of noise canceling devices were applied, the noise level reduced to 67.4 - 73.8 dB. All 4 devices had statistically significant effect in reducing the noise of the handpiece. Considering the intensity and exposure time, noise in dental clinics can cause hearing damage to dentists. For protection from the risk of occupational hearing damages, noise canceling devices can be recommended.

A comparative study on the user satisfaction between two different piezoelectric engines (두가지 피에조 엔진의 사용자 만족도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Choi, So-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.269-277
    • /
    • 2017
  • Purpose: The aim of this study is to compare the performance of two piezoelectric engine systems by surveying satisfaction from dental clinicians. Materials and Methods: Two piezoelectric systems were evaluated: TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). For this study, 20 dentists responded to the 11 questionnaires in which 5 point Likert-type scale was used. The two devices were operated for 10 seconds and measured 5 times to compare the maximum noise values. In heat emission test, the handpiece was operated for 3 minutes and heat was measured at three positions each. Results: TRAUS XUS10 had higher satisfaction level on motor noise (P < 0.05). About function key and handpiece heat generation, PIEZOSURGERY touch showed higher satisfaction (P < 0.05) than TRAUS XUS10. The maximum noise level for each of the devices was confirmed to be 56.6 dB for the TRAUS XUS10 and 56.0 dB for PIEZOSURGERY touch. The two piezoelectric engines satisfied the safety standards with an operation temperature below $41^{\circ}C$ after having been operated for 3 minutes. Conclusion: Except for the function key and handpiece heat emission, TRAUS XUS10 has comparable performance with PIEZOSURGERY touch.

Temporary Threshold Shift of Vibration Sensation by Dental Handpiece (치과용 핸드피스에 의한 일시적 진동감각역치 변화)

  • Kim, Seong-Ah;Lee, Jong-Young;Kim, Doo-Hie;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.765-771
    • /
    • 1995
  • This study was performed to investigate the possibility of temporary threshold shift (TTS) of vibration sense could induced by exposure to high-frequency vibration or by work position taking by dentists in drilling or polishing. The vibratory perception thresholds (VPT) of 28 healthy men were measured on the index fingertip pulp of dominant hand at 250 Hz. The vibrating tool used in test was a low-speed handpiece of 34,000 rpm. For the TTS test, the dominant hand was exposed to high-frequency vibration and to work position for five minutes, respectively. The VPTs before and after vibratory exposure were $23.5{\pm}3.5dB,\;30.8{\pm}4.2dB$, respectively and VPT after work position was $23.7{\pm}4.6dB$. The difference between before and after vibartory exposure was statistically significant (p<0.001). The correlation of height, weight and BMI with baseline VPTs was not statistically significant. Also, there was no difference of VPTs by smoking. These results suggest that high-frequency vibration from dental handpieces might cause the impairment of vibration sensation.

  • PDF