Free-vibration and buckling of Mindlin plates using SGN-FEM models and effects of parasitic shear in models performance

  • Leilson J. Araujo;Joao E. Abdalla Filho
    • Structural Engineering and Mechanics
    • /
    • v.87 no.3
    • /
    • pp.283-296
    • /
    • 2023
  • Free-vibration and buckling analyses of plate problems are investigated with the aid of the strain gradient notation finite element method (SGN-FEM). As SGN-FEM employs physically interpretable polynomials in developing finite elements, parasitic shear sources, which are the cause of shear locking, can be precisely identified and subsequently eliminated. This allows two mutually complementary objectives to be defined in this work, namely, evaluate the efficiency of free-vibration and buckling results provided by corrected models, and study the severity of parasitic shear effects on plate models performance. Parasitic shear are flexural terms erroneously present in shear strain polynomials. It is reviewed here that six parasitic shear terms arise during the formulation of the four-node Mindlin plate element. Two parasitic shear terms have been identified in the in-plane shear strain polynomial while other two have been identified in each of the transverse shear strain polynomials. The element is corrected a-priori, i.e., during development, by simply removing the spurious terms from the shear strain polynomials. The computational implementation of the element in its two versions, namely, containing the parasitic shear terms (PS) and corrected for parasitic shear (SG), allows for assessments of the accuracy of results and of the deleterious effects of parasitic shear in free vibration and buckling analyses. This assessment of the parasitic shear effects is a novelty of this work. Validation of the SG model is done comparing its results with analytical results and results provided by other numerical procedures. Analyses are performed for square plates with different thickness-to-length ratios and boundary conditions. Results for thin plates provided by the PS model do not converge to the correct solutions, which indicates that parasitic shear must be eliminated. That is, analysts should not rely on refinement alone. For thick plates, PS model results can be considered acceptable as deleterious effects are really critical in thin plates. On the other hand, results provided by the SG model converge well for both thin and thick plates. The effectiveness of the SG model is established via high-accuracy results obtained in several examples. It is concluded that corrected SGN-FEM models are efficient alternatives for free-vibration and buckling analysis of Mindlin plate problems, and that precise elimination of parasitic shear is a requirement for sound analyses.

Experimental and analytical study of squat walls with alternative detailing

  • Leonardo M. Massone;Cristhofer N. Letelier;Cristobal F. Soto;Felipe A. Yanez;Fabian R. Rojas
    • Computers and Concrete
    • /
    • v.33 no.5
    • /
    • pp.497-507
    • /
    • 2024
  • In squat reinforced concrete walls, the displacement capacity for lateral deformation is low and the ability to resist the axial load can quickly be lost, generating collapse. This work consists of testing two squat reinforced concrete walls. One of the specimens is built with conventional detailing of reinforced concrete walls, while the second specimen is built applying an alternative design, including stirrups along the diagonal of the wall to improve its ductility. This solution differs from the detailing of beams or coupling elements that suggest building elements equivalent to columns located diagonally in the element. The dimensions of both specimens correspond to a wall with a low aspect ratio (1:1), where the height and length of the specimen are 1.4 m, with a thickness of 120 mm. The alternative wall included stirrups placed diagonally covering approximately 25% of the diagonal strut of the wall with alternative detailing. The walls were tested under a constant axial load of 0.1f'cAg and a cyclic lateral displacement was applied in the upper part of the wall. The results indicate that the lateral strength is almost identical between both specimens. On the other hand, the lateral displacement capacity increased by 25% with the alternative detailing, but it was also able to maintain the 3 complete hysteretic cycles up to a drift of 2.5%, reaching longitudinal reinforcement fracture, while the base specimen only reached the first cycle of 2% with rapid degradation due to failure of the diagonal compression strut. The alternative design also allows 46% more energy dissipation than the conventional design. A model was used to capture the global response, correctly representing the observed behavior. A parametric study with the model, varying the reinforcement amount and aspect ratio, was performed, indicating that the effectiveness of the alternative detailing can double de drift capacity for the case with a low aspect ratio (1.1) and a large longitudinal steel amount (1% in the web, 5% in the boundary), which decreases with lower amounts of longitudinal reinforcement and with the increment of aspect ratio, indicating that the alternative detailing approach is reasonable for walls with an aspect ratio up to 2, especially if the amount of longitudinal reinforcement is high.

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

Estimation of Genetic Parameters and Genetic Trends for Major Economic Traits in Swine (종돈의 주요 경제형질에 대한 유전모수 및 유전적 변화 추세 추정에 대한 연구)

  • Kang, Hyun-Sung;Nam, Ki-Chang;Li, Yunxiao;Kim, Kyung-Tai;Lee, Myeong-Seop;Yoon, Jong-Taek;Seo, Kang-Seok
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.89-94
    • /
    • 2012
  • The objective of this study was to estimate the genetic parameters and breeding value of swine using their economic traits. The traits considered were age at 90 kilograms body weight (D90 kg), backfat thickness (BF) and eye muscle area (EMA). Estimation of genetic parameters and breeding value from 18,668 heads considering the economic traits were based on farm performance data from May 2007 to April 2011. Estimation of genetic parameters based on economic traits revealed that the single best model was fitted after finding source of variance on fixed and random effects and estimated by a multiple trait model using DF-REML (Derivative-FREE Restricted Maximum Likelihood). In this study, the estimated heritabilities of Duroc, Berkshire, Landrace and Yorkshire were about 0.22-0.59 for the D90 kg, 0.47-0.62 for the BF and 0.23-0.37 for the EMA. Genetic correlation of D90 kg with BF and EMA of the four breeds were -0.01-0.24 and -0.35--0.23, respectively. Moreover, the genetic correlation of BF with EMA was -0.68--0.17. On the other hand, the phenotypic correlation of D90 kg with BF and EMA of the four breeds were about 0.01-0.11 and -0.37--0.21, respectively, while the phenotypic correlation of BF with EMA was -0.68--0.17. Results showed that the genetic trends of breeding value every year were decreasing for D90 kg, increasing for BF while for EMA inconsistent values were obtained.

A Study on the Adolescent Growth Spurt of Skinfold, Muscle and Bone Variables Aligned on Peak Height Velocity in Boys and Girls (PHV 척도를 기준한 피하지방후, 근과 골 변인의 사춘기 발육분출에 관한 연구)

  • Shin Sang-Keun
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.339-344
    • /
    • 2006
  • The aim of this study was to examine the timing and magnitude of growth spurt in skinfold, body musle and bone related variables aligned on peak height velocity in boys and girls. In the study design, the subjects and the method were used by the cross-sectional investigation. The subjects participated in this study were 7 through 18 years of age belonged to typical primary, junior, senior high school students, and about 250 males and 250 females in each age group. The total subjects were 2,798 males and 2,762 females. All subjects of this study were lived in Pusan metropolitan city, Korea. The growth velocity magnitudes of sum of the four sites sknfold thickness, body musle and bone related variables. Velocity curve chart of physique was the smoothed according to an approximation of splines by the Sigma Plot-2001 graphic program. In this study, age at PHV of girls occurred eariler about 2 years than boys. In sum of four sites skinfold thickness, PV occurred -2 years from PHV in boys, and PV occurred +2 years from PHV in girls, respectively. In humerus breadth, two PV occurred before and after PHV in boys, whereas PV occurred -1 year from PHV in girls, respectively. In femur breadth, PFV and PHV appeared to occure the same time in boys, PV occurred -2 years from PHV in girls, respectively, In arm circumference, PV occurred after PHV in both sexes. In calf circumference, PV occurred +2 years from PHV in boys, PCCV and PHV appeared to occure the same time in girls, respectively. In magnitudes of peak velocity of body height, humerus breadth, femur breadth, arm circumference and calf circumfence, boys obtained higher than girls, on the other hand, girls obtained higher than boys in sum of four sites skinfold variable. we need to longitudinal and scientific investigation by Korean government level in adolescent growth spurt study, because childhood and adolescence achive higher positive physical education effect than the other ages.

Analysis of Treatment and Prognosis in Malignant Melanoma (악성 흑색종의 치료와 예후에 대한 분석)

  • Kwon, Young-Ho;Kim, Jeong-Ryoul;Lee, Young-Gu;Kim, Jae-Do
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.141-147
    • /
    • 2005
  • Purpose: The most important thing in curing Malignant melanoma is surgical excision, operating method is wide excision. The author et al. studied 5-year survival rate of each stage and appropriate surgical margin after operating wide excision and immuno-chemotherapy. Materials and methods: From March 1995 to August 2003, wide excision and immunochemotherapy were operated to 35 patients (17 males and 18 females) who were diagnosed as malignant melanoma and followed up. Excision was done around 2 cm from edge of tumor regardless of the size or effected degree of the skin, and flap or full thickness skin graft was used for skin deficit that was not covered after excision. As for immuno-chemotherapy, method that prescribes 400 mg of dacarbazine (DTIC) and 3 million IU of interferone-${\alpha}$ in combination was used. Immuno-chemotherapy was operated to patients in over stage III. We used AJCC stage that was revised in 2002. Local recurrence, local metastasis and distant metastasis were investigated for these patients as well as the 5-year survival rate of each stage. Results: Most frequently 15 cases(42.8%) occurred in foot, 5 cases(14.2%) occured in ankle, 2 cases(5.7%) in leg, 2 cases(5.7%) in thigh and 5 cases(14.2%) in hand. The incidence of each stage were 8 cases(22.8%) in IA, 9 cases(25.7 %) in IB, 4 cases(11.4%) in IIA, 2 cases(5.7%) in IIB, 1 cases(2.8%) in IIIA, 2 cases(5.7%) in IIIB, 2 cases(5.7%) in IIIC and 7 cases(20.0%) in stage IV. 5-year survival rate of each stage were 94.1% in stage I, 66.8% in stage II, 40% in stage III and 14.3% in stage IV. Conclusion: 5-year survival rate of stage IV was low in malignant melanoma. In treatment of malignant melanoma, staging before operation is important as operation methods are different from each stage. We recommend wide excision which remove around 1~3 cm from margin of tumor up to each thickness.

  • PDF

A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage (청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구)

  • 이석건;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.1
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

Shallow Subsurface Structure of the Yaksoo Area, Ulsan, Korea by Geophysical Surveys (물리탐사기법에 의한 울산광역시 약수지역 천부지하구조 조사)

  • Lee, Jung-Mo;Kong, Young-Sae;Chang, Tae-Woo;Park, Dong-Hee;Kim, Tae-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 2000
  • The location and geometry of the Ulsan Fault play important roles in interpreting tectonic evolution of the southeastern part of the Korean Peninsula. Dipole-dipole electrical resistivity surveys and seismic refraction surveys were carried out in the Yaksoo area, Ulsan in order to measure the thickness of the alluvium covering the Ulsan Fault and to find associated fracture zones and possibly the location of its major fault plane. The collected data were analyzed and interpreted. Some results reported previously by others were also used in this interpretation. No low resistivity anomalies were found in the cross-sectional resistivity image of the survey line located in the east of the Dong River. In contrast, well-developed continuous low resistivity anomalies were detected in the west of the Dong River. This strongly suggests that the major fault plane of the Ulsan Fault is located under or in the west part of the Dong River. Two refraction boundaries corresponding to the underground water level and the bottom of the alluvium were found by refraction surveys carried out on the limited part of the east survey line. The thickness of the alluvium was found to be about 30 m. Small faults in the basement rock identified by reflection surveys were not detected by both resistivity and refraction seismic surveys. This might be explained by assuming that low resistivity anomaly is more closely related to the clay contents than the water contents. On the other hand, it may be resulted by the limited resolution of the resistivity and refraction surveys. Detailed study is required to clarify the reason. Resistivity survey is frequently considered to be a good exploration method to detect subsurface faults. However, it appears to be less useful than reflection seismic survey in this work. In dipole-dipole resistivity survey, the number of separation should be increased to survey deeper subsurface with the same resolution. However, signal to noise ratio decreases as the number of separation increases. In this survey area, the signal to noise ratio of up to sixteen separations was good enough based on the statistical properties of measurements.

  • PDF

Anti-Inflammatory Effects of Poly-${\gamma}$-Glutamic Acid on DNCB-Induced Allergic Contact Dermatitis in Dogs (개에서 DNCB에 의해 유발된 알레르기성 접촉피부염에 대한 폴리감마글루탐산의 항염증 효과)

  • Kim, Hyun-Gon;Kim, Kil-Soo;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.283-296
    • /
    • 2012
  • Allergic contact dermatitis (ACD) is an inflammatory skin disease and regarded as a prototype of T-cell mediated delayed-type hypersensitivity reactions. Poly-${\gamma}$-glutamic acid (PGA) is a biodegradable polymer that is produced by Bacillus subtilis. This study was performed to assess the effects of PGA in a canine model of ACD. ACD was induced on the back of dogs induced by sensitization and repeated application by 2,4-dinitro-1-chlorobenzene (DNCB). Topical treatment of PGA was applied once a day for 12 days and skin biophysical parameters including transepidermal water loss (TEWL), skin hydration, skin pH, skin thickness and erythema index, were measured every two days during experimental periods. Histopathology and immunohistochemistry were performed to evaluate the antiinflammatory effect. In skin biophysical parameters, TEWL, skin hydration, skin thickness and erythema index were significantly increased, with a maximum increase appeared on day 2 (p < 0.05). On the other hand, skin pH was significantly decreased, with a maximum decrease appeared on day 2 (p < 0.01). After the completion of PGA treatment, skin biophysical parameters were significantly reached those of baseline in a time-dependent manner (p < 0.05). In histopathology, marked increases of epidermal thicknesses were induced after DNCB challenge with numerous inflammatory cell infiltrations and edematous changes, decreases of connective tissue occupied regions in dermis. In addition, marked increases of cytokine - tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) and interferon-${\gamma}$ (IFN-${\gamma}$)-immunoreactivities in the dermis and of apoptotic markers - caspase-3 and PARP-immunoreactivities in the epidermis were observed in DNCB-PBS control as compared with intact control, respectively (p < 0.01). It means, the ACD and related apoptotic changes were induced by DNCB in the present study. However, these ACD induced by DNCB and related apoptosis in epidermis were significantly inhibited by treatment of PGA treated skin, the decreases of infiltrated inflammatory cells and related decreases of pro-inflammatory cytokine immunoreactivities were also observed (p < 0.01). Based on these findings, PGA may have anti-inflammatory and alleviatory effects in the allergic contact dermatitis.

The Clinical Value of Intima-media Thickness in Patients with Stable Coronary Artery Disease and C-reactive Protein within Normal Limits (경동맥 내중막 두께가 정상 C-반응성 단백질 농도를 가진 안정형 협심증 환자에서 가지는 임상적 의의)

  • Kwon, Jong-Bum;Park, Kuhn;Choi, Si-Young;Park, Chan-Beom;Kim, Yong-Hwan;Her, Sung-Ho;Park, Mahn-Won;Lee, Jong-Ho
    • Journal of Chest Surgery
    • /
    • v.43 no.5
    • /
    • pp.482-489
    • /
    • 2010
  • Background: The purpose of this study was to determine whether hand-measured carotid intima-media thickness (IMT) was a reliable and simple tool that could be used to evaluate the severity of stable coronary artery disease (CAD) with normal high-sensitivity C-reactive protein (CRP). Material and Method: We examined left carotid IMTs in 688 patients with stable CAD and excluded 121 patients with abnormally elevated hs-CRP ($\geq$0.5 mg/dL). We sought to determine the association between risk factors and the severity of stable CAD and carotid IMT in 567 patients who were divided into lower and higher groups based on the median value. Patients underwent a coronary artery angiogram and had at least significant stenosis (>50% of the original luminal diameter involving one or more major coronary artery). Result: Of the 567 patients, 300 (52.9%) were in the lower IMT group and 267 (47.1%) were in the higher IMT group; the median value was 0.76 mm. By multivariable logistic regression analysis, the following groups were different: older age (~49 vs. 70~ years, respectively; OR=6.552), high FBS (~99 vs. 120~ mg/dL; OR=1.713) and severity of CAD (1 vessel vs. 2 vessel disease; OR=1.711, 1 vessel vs. 3 vessel disease; OR=1.714). Conclusion: We conclude that there are correlations between increased carotid IMT and severity of CAD in stable angina patients with normal CRP levels.