• Title/Summary/Keyword: hand measurement

Search Result 1,074, Processing Time 0.021 seconds

SC4/Trends in Standards and Regulations on Hand-arm Vibration (SC4/수완계 진동 측정 관련 규격 제정동향)

  • 장한기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.455-458
    • /
    • 2003
  • Effect of hand-transmitted vibration on human discomfort and health was reviewed. Since the effect by hand tool was more serious than those by any other vibration environments, western countries have protected hand tool workers by regulations. International organization for standardization legislate standard, ISO 5349, at 1979 for the measurement and evaluation of the effect. Afterwards, more than twenty standards on hand-arm vibration were enacted to protect any damage of hand tool users. Even though Korea Standards adopted ISO 5349 in 2001, it is required an action plan should be applied to all of work environments, especially to the workers using pneumatic tool workers such as miners, construction workers, and etc.

  • PDF

Comparison and Analysis on the Assessment Methods of Human Effects of Hand-arm Vibration (수완계 진동에 대한 인체 영향 평가 기법의 비교 분석)

  • 정완섭;권휴상
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1361-1364
    • /
    • 2001
  • The recent national contract (Ecotechnopia 21) supported by the ministry of environment puts much significance on new issues for the assessment of human effects arising from vibration and noise exposed to human. This paper focuses only on hand-arm vibration since it has been a major problem in protecting vibration exposure to human. To set up a systematic way of assessing adverse effects of hand-arm vibration, surveys were made on recent international standards and researches related to hand-arm vibration. The measurement and evaluation methods of hand-arm transmitted vibration, the relationship between vibration exposure and effects on health, and the assessment methods of nerve dysfunctions are addressed in this paper. Those methods are linked into a logical way of assessing effects of hand-arm vibration on human. Finally, the current activities and achievements in this work are briefly summarised.

  • PDF

Hand Sizing Study for Development of Firefighting Gloves (소방공무원의 장갑제작을 위한 손 치수 연구)

  • Kwon, Chae-Ryung;Jang, Mina;Jeong, Da Wun;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.3
    • /
    • pp.416-426
    • /
    • 2019
  • This study measured and analyzed male firefighters hand sizes as well as suggested data for developing firefighting gloves with a good fit. Accordingly, body dimensions related to the hand were measured for 100 male firefighters. Twenty-three measuring items related to the hand and lower arm were selected. The firefighters' measurement data were compared to general adult male measurements from the 6th Korean Anthropometric data to analyze the hand sizes characteristics of firefighters. As a result, height, hand circumference, hand breadth, wrist circumference, elbow-wrist length, forearm-fingertip length and firefighter weight were significantly larger than adult males. A correlation analysis for 23 items was conducted to select items used as standards for setting a size when manufacturing firefighting gloves. Hand length and circumference were selected as representative hand parts for making firefighting gloves. Cross analysis between hand length and circumference were conducted to find the section showing the highest distribution ratio. As a result, the highest sections were between 19cm and 21cm for hand circumference and between 18.5cm and 19.5cm for hand length, which may be suggested as the most important ranges.

An Analysis of Hand Measurements for Designing Size Specification for Children's Gloves (아동용 장갑의 치수 규격 설계를 위한 손 치수 분석)

  • Jeon, Eunkyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.923-934
    • /
    • 2021
  • Most apparel products have national standards for sizing; however, for gloves, national sizing standards have not yet been established. This study aims to analyze children's hand dimensions and propose a size specification for children's gloves that shows children's hand-related size information. Among the 3D measurements of sixth Size Korea Project, the measurement data of 19 dimensions related to the hands of 1,057 boys and girls aged 7-13 years old were analyzed. The distribution and growth trend of hand measurements for boys and girls demonstrated considerable mean differences and distribution trends by gender and age as per hand dimensions, which leads to the conclusion that it is necessary to show these results in the children's glove design. Based on these results, the cross-distribution maps of children's hand length and hand circumference were drafted; furthermore, the distribution relationship with an adult hand size was identified. Based on the distribution of hand sizes, the distribution of adult hand sizes overlapped with children's hand sizes was verified, and children's glove size specifications were presented. The results can be used as useful data such as measures for setting the size range and sizing system for children's gloves.

Development and Evaluation of Tip Pinch Strength Measurement on a Paretic Hand Rehabilitation Device

  • Kim, Jung-Yeon;Cha, Ye-Rin;Lee, Sang-Heon;Jung, Bong-Keun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.1201-1216
    • /
    • 2017
  • In this study, we described the development of a methodology to measure tip-pinch strength on the paretic hand rehabilitation device and aimed to investigate reliability of the device. FSR sensors were embedded on the device, and tip pinch strength was estimated with data collected from the sensors using a developed equation while participants were demonstrating tip pinch. Reliability tests included inter-rater, test-retest, and inter-instrument reliability. B&L Engineering pinch gauge was utilized for the comparison. Thirty-seven healthy students participated in the experiment. Both inter-rater and test-retest reliability were excellent as Intraclass Correlation Coefficients (ICCs) were greater than 0.9 (p<0.01). There were no statistically significant differences in tip-pinch strengths. Inter-instrument reliability analysis confirmed good correlation between the two instruments (r = 0.88, p < 0.01). The findings of this study suggest that the two instruments are not interchangeable. However, the tip-pinch mechanism used in the paretic hand rehabilitation device is reliable that can be used to evaluate tip pinch strength in clinical environment and can provides a parameter that monitors changes in the hand functions.

Evaluation of Hand-Arm Vibration in Swaging Process (스웨징 작업에서의 국소진동 노출평가)

  • 박인선;박원형;박상규;김규상
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • This study is performed to evaluate hand-arm vibration syndrome(HA VS) of the workers in swaging process. Vibration measurement and assessment of human exposure are based on the international standard(ISO 5349). Triaxial acceleration of each operation and exposure time are measured to predict the periods before finger blanching, As results, it is found that acceleration is concerned with the diameter of pipes in swaging process, and also found that combined work is more harmful than a single operation.

  • PDF

Hand arm vibration measurement using micro-accelerometer in different brick structures

  • Gomathi, K.;Senthilkumar, A.;Shankar, S.;Thangavel, S.;Priya, R. Mohana
    • Smart Structures and Systems
    • /
    • v.13 no.6
    • /
    • pp.959-974
    • /
    • 2014
  • Hand-Arm Vibration Syndrome (HAVS) is a group of diseases caused by exposure of the hands to vibration while operating the hand held power tools such as road breaker, drilling machine, demolition hammer in construction works. In this paper, area-changed capacitive micro-accelerometer is designed to measure the vibration exposure on worker's hand when operating a drilling machine on various blocks such as clay block, paver block and solid cement block. The design process includes mathematical modelling of micro-accelerometer and simulations are done using INTELLISUITE 8.6. Experimental results are taken for various blocks surfaces using conventional and micro-accelerometer. Comparisons show that usage of area-changed micro-accelerometer for Hand-arm vibration monitoring provides better sensitivity, which in turn reduces the risk of HAVS in workers.

investigation on Human Effects of Vibration and Noise Exposed on Human: I. Human Vibration (인체 진동소음의 인체영향에 대한 국내외 기술조사 : 인체 진동)

  • 정완섭;권휴상
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.691-694
    • /
    • 2001
  • The recent national contract (Ecotechnopia 21) supported by the ministry of environment puts much significance on new issues for the assessment of human effects arising from vibration and noise exposed to human. This paper focuses only on hand-arm vibration since it has been a major problem in protecting vibration exposure to human. To set up a systematic way of assessing adverse effects of hand-arm vibration, surveys were made on recent international standards and researches related to hand-arm vibration. The measurement and evaluation methods of hand-arm transmitted vibration, the relationship between vibration exposure and effects on health, and the assessment methods of nerve dysfunctions are addressed in this paper. Those methods are linked into a logical way of assessing effects of hand-arm vibration on human. Finally, the current activities and achievements in this work are briefly summarised.

  • PDF

Development and Verification of a Hand-held Typed Monitoring System for Cardiac Output Measurement using Electrical Impedance Technique (전기적 임피던스 방법을 통한 hand-held 타입의 심박출량 모니터링 시스템 개발 및 검증)

  • Seo, Kwang-Seok;Sim, Myeong-Heon;Kim, Min-Yong;Yoon, Chan-Sol;Chung, Joo-Hong;Park, Sung-Bin;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1932-1938
    • /
    • 2012
  • The impedance cardiogram has been proposed as a non-invasive, continuous, operator independent, and cost-effective method for cardiac output monitoring. However, it can not be completely considered as non-restrictive method because of attached spot and band type electrodes. Therefore, we developed a improved convenient hand-held typed measurement system for cardiac output by electrical impedance technique. 80 subjects from Yonsei University and the surrounding areas, participated. All subjects measured stroke volume and cardiac output through Physioflow and developed system. To verify the developed system, statistical methods such as correlation, Wilcoxon signed ranks test, and the Bland-Altman analysis were used. The proposed system showed significant correlation in both male and female stroke volume(r=0.715, r=0.704) and cardiac output(r=0.826; r=0.804). From these results, it can be concluded that stroke volume and cardiac output could be improved convenient measurement using the both hands without the help of a specialist.

Islamic Religiosity Scale, and Its Applied on the Relationship Between Religiosity and Selection of Islamic Bank

  • Usman, Hardius
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.3 no.3
    • /
    • pp.1-13
    • /
    • 2015
  • The purposes of this research are to develop a measurement of Islamic religiosity and applying these measurements to examine the relationship between religiosity and selection of the Islamic bank. Literature searches and in -depth interviews are used to obtain the statement item to build measurement. Furthermore, result of the religiosity measurement will be used to study the relationship between religiosity and the selection of the Islamic bank. Population of the study is Muslim who has bank(s) account. A total 375 questionnaires were distributed to the three groups of bank customers (125 respondents in each group). This res earch has successfully developed a measurement of religiosity, which is called Islamic Religiosity Scale (IRS). On the one hand, the study indicate that religiosity plays a significant role on the decision of customers to choose Islamic banks, because the degree of religiosity of Islamic bank customers is higher than conventional bank customers. Nevertheless, on other hand, this study also revealed that religiosity is not the only factor that influences customers to selecting the Islamic banks, because the degree of religiosity of Islamic bank customers do not differ significantly with customers who hold accounts in both bank.